• Battery Solar Wind Power System High Temperature 2V 2000AH System 1
  • Battery Solar Wind Power System High Temperature 2V 2000AH System 2
  • Battery Solar Wind Power System High Temperature 2V 2000AH System 3
Battery Solar Wind Power System High Temperature 2V 2000AH

Battery Solar Wind Power System High Temperature 2V 2000AH

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 pc
Supply Capability:
1000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Range summary


313K Series batteries are designed for high-temperature environment and new energy such as wind energy, photovoltaic energy storage system. With high temperature resistance, long life, safety and reliability characteristics, 313K series is widely used in telecommunications, electric power, energy storage, and it ideal for cycle or hybrid system in harsh, high temperature environment.
The 313K series batteries are ensured the quality with NARADA's QA system according to the ISO9001&ISO14001 standard.


Features and Benefits

1.     Patented anti-corrosion grid technology

2.     Optimized active material for high temperature conditions

3.     Unique high temperature case material with HDT in excess of 124oC

4.     Increased internal compression for improved cycling endurance

5.     Oxygen catalyst to reduce float currents and extend cycling capability

6.     Containers & lids UL94 V-0 rated

7.     Advanced negative plate protection system

8.     Wide operating temperature range:-40oC to +80oC

9.     Normal operating temperature is 35oC

10.  Excellent deep cycling capability systems

11.  Suitable for continuous operation at temperatures in excess of 35oC

12.  Reduced system operating costs 25% electricity power saving

13.  Up to 100% air conditioner maintenance saving

14.  Up to 100% condensing agent saving

15.  30% CO2 gas emission reduce

16.  Less than 1 year payback period depend on environment

Compliant standards

1.     IEC60896-21/22

2.     IEC61427

3.     BS6290 part 4

4.     Telcordia SR4228

5.     Eurobat guide

6.     UL

7.     Manufactured under system ISO9001(TUV) and ISO14001

Battery installation compliant with:

1.     EN 50272-2 or local equivalents

Main applications

1.     Hybrid telecom remote base stations

2.     Renewable energy wind & solar sites

3.     Grid frequency leveling systems

4.     All back-up applications where grid reliability is poor

5.     All extreme environment off-grid

Products characteristics:

1.     Recommended float charge voltage for 2V battery: 2.24Vpc at 35oC(95oF), 2.27Vpc at 25oC(77oF)

2.     Self discharge rate :<5% per month at 35oC(95oF)

3.     Design life: 15 years at 35oC (95oF)

4.     VRLA high temperature battery, no water addition required

Technical Data:

Battery Solar Wind Power System High Temperature 2V 2000AH


Q: How to repair the battery?
Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
Q: What is the difference between a maintenance-free battery and a conventional battery?
Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
Q: How to deal with waste batteries?
The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.
Q: What battery does the van use?
The battery is mainly composed of tube positive plate, negative plate, electrolyte, separator, battery compartment, battery cover, pole, injection liquid cover and so on. The electrode of the exhaust type battery is made of lead and lead oxide, and the electrolyte is an aqueous solution of sulfuric acid. The main advantage is the voltage stability, the price is cheap; the disadvantage is lower than the energy (that is, per kilogram of battery storage power), short life and routine maintenance frequently. Old ordinary battery life of about 2 years, and the need to regularly check the height of the electrolyte and add distilled water. However, with the development of science and technology, lead-acid battery life becomes longer and maintenance is also more simple.
Q: What is the meaning of the battery above 12v65Ah?
12V is said to be the voltage, 65Ah is the current. (A is the unit of current. H is the time unit .1 hours.)
Q: How should the battery be well maintained?
Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
Q: What kind of battery is divided into?
At present, we used the car battery is divided into three categories, namely, ordinary batteries, dry batteries and maintenance-free batteries three.
Q: What is a maintenanceable battery?
This is relative to a maintenance-free battery. Maintenance of the battery needs to be supplemented with electrolyte to ensure work, while maintenance-free is not required.
Q: How does battery activation work?
If you are talking about dry batteries, that is, to add sulfuric acid can use the battery (commonly known as water bottles), then it is because the long-term storage so that a high degree of oxidation of the negative board, plus acid will be a high temperature, Low, you can add acid in the pool after the addition of a small current for a long time to charge, you can solve. Generally with 0.05C charge to 3 times can be.
Q: Lead-acid battery how to maintain?
After passing the test, cover the exhaust cutting, pay attention to restore the filler, cover the battery cover, if the cover is glued, then glue bonding.