• Raw Materials for Refractory - Abrasive White Fused Alumina (WFA) for Sand Blasting 230 Mesh System 1
  • Raw Materials for Refractory - Abrasive White Fused Alumina (WFA) for Sand Blasting 230 Mesh System 2
Raw Materials for Refractory - Abrasive White Fused Alumina (WFA) for Sand Blasting 230 Mesh

Raw Materials for Refractory - Abrasive White Fused Alumina (WFA) for Sand Blasting 230 Mesh

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Packaging & Delivery

Packaging Detail:25kg/plastic bag, 1mt/jumbo bag or as you require
Delivery Detail:within 7 days after sign the contract or your deposit

Specifications

white fused alumina
Direct Manufacturer
lapping & polishing media
Ceramic grinding wheels

                       230 mesh abrasive white fused alumina (WFA) for sand blasting

White Fused Alumina/ WFA

White Fused Alumina, a kind of high-grade refractories, was made from the high quality alumina by melting above 2000 in the electric arc furnace and cooling. It is white with the main crystal phase alpha-Al2O3.The white alumina produced in titling electric arc furnace has the advantage of high bulk density and low porosity and the volume stability and thermal shock resistance can be improved.

Advantages

Flexible price policy

Equipped full line of test method.

Brilliant produce&supply&delivery ability

We passed the certification of ISO9001:2000

White fused alumina has Al2O3 content 99% min

All products will be supplied according to customers different requirement.

The laboratory is certified by government Inspection Bureau, that assures its quality stability.

Technical Data:

Application

specification

major chemical content %

AL2O3

Na2O

SiO2

K2O

Fe2O3

abrasive

F

8#-60#

99.5min

0.26max

0.08max

0.06max

60#-100#

99.5min

0.26max

0.09max

0.06max

120#-150#

99.5min

0.26max

0.10max

0.06max

180#-220#

99.5min

0.26max

0.12max

0.10max

230#-800#

99.3min

0.32max

0.15max

0.10max

1000#-3000#

99.1min

0.35max

0.18max

0.10max

refractory

Section sand

0-1mm

99.5min

0.29max

0.30max

0.02max

0.06max

1-3mm

3-5mm

5-8mm

10-20mm

0.3-1mm

0-0.3mm

1-2mm

0.5-1.5mm

Fine powder

100#-0

99.0min

0.40max

0.30max

0.03max

0.20max

Moh's hardness

≥9.0

true density(g/cm3)

≥3.95

propotion

≥3.6

porosity

≤8.5

As refractoriness

White Fused Alumina is the main starting material to produce high-grade unshaped and shaped refractoriness and is widely used in the field of iron-steel industry,ceramics,petrochemical industry etc. It is the ideal material to produce the unshaped refractoriness such as large ladle castables,medium and high grade BF trough castables,gunning material,pre-cast shapes and is the main material to produce alumina products such as corundum bricks, corundum and mullite-corundum sagger,refined porous plug bricks, monolithic lance composite nozzle, lining material for high temperature industrial furnaces,etc.

As abrasives

White Fused Alumina can be used as consolidation & coating abrasives, wet or dry sprayed grit, suitable for ultra-precise grinding and polishing in the crystal and electronic industry and can be used to produce high-grade refractoriness. It is suitable to machine high stiffness &high tensile strength materials such as chilled steel, alloyed steel, high-speed steel, high carbon steel, etc. In addition, it can be used as catalyst, insulator, precise foundry sand, etc.

Size available:

Abrasive tool: F10-F220,F230-F1200;P12-P220;

Refractory  : 0-1mm,1-3mm,3-5mm,5-10mm;100mesh,325mesh;

Other size is available as required;          

Packing:

25kg/bag,40bags/big bag;

1000kg/big bag;

1000kg/big bag with pallet packing;

Other packing is allowed as required.

Q: Who knows the setting requirements of roofing fire barrier zone?
First, the the minimum of fire barrier width is greater than 30cm, and the thickness should be same to the thickness of the insulation materials. Fire barrier zone insulation board must do the whole area sticking construction with the base wall during the construction. Fire barrier zone insulation board is required to assistant binding by anchor bolt, anchor bolt must suppress the underlying mesh. Second, Fire barrier zone should be set at the upper position of door and window openings, the distance between the low edge of isolation belt and the upper edge of the window must be less than 50cm. The thermal resistance of fire barrier zone must be half than EIFS thermal resistance in the cold northern areas, while the thermal resistance of fire barrier zone must be three times than EIFS thermal resistance in the hot summer and cold winter area. Third, When the fire barrier zone is set on the edge of the window, fire barrier zone at the upper part of the window should do flanging when sticking, flanging glass fiber mesh must exceed 10CM than firebreak insulation board. Flanging network, underlying network and surface network can not be overlapped or butted at the top of the window. I hope you can be satisfied
Q: How to distinguish the fire resistant level of the rubber and plastic thermal insulation material?
Fire?rating grading of external wall thermal insulation materials. 1, China's national standard GB8624-97 divides the combustion performance of building materials external insulation materials into the following grades. Level A: Incombustible materials: Almost no burning materials. Level B1: Incombustible materials: Flame-like material has good fire-retardant effect. In case of fire in the air or at high temperature, it is difficult to fire and doesn't spread quickly, and when the fire source is removed after combustion, it stops immediately. Level B2: Incombustible materials: Combustible materials have a certain flame resistance. In case of fire in the air or at high temperature, it will immediately burst into flames, and easily leads to the spread of fire, such as poles, wooden frame, wooden beams and wooden stairs,ect. Level B3 : Incombustible materials: No flame-retardant effect, hidhly flammable and high fire risk. 2, The external wall thermal insulation materials could be divided according to the fire?rating. 1) thermal insulation material that has the level A combustion performance: Spraying inorganic fiber, glass wool, foam glass, ceramic foam, rock wool, foam cement and perlite obturator, and so on. 2), The thermal insulation material that has level B1 combustion performance: Special processed extruded polystyrene board (XPS) / special processed polyurethane (PU), phenolic and polystyrene powder. 3), Thermal insulation materials that have level B2 combustion performance: Molded polystyrene board (EPS), extruded polystyrene board (XPS), polyurethane (PU), polyethylene (PE), etc.
Q: What's the requirements of fire-fighting criteria of heat insulating material?
It shouldn't be under than B2 level. Roofing insulation fire rating requirements: the ministry of public security, housing and urban-rural development department issued about printing and distributing the civil building external thermal insulation system and the interim provisions on the exterior wall decorative fireproof prescribed in the notice: roof grassroots adopted duration of fire resistance is the non-combustible component that shouldn't less than 1.00 h's. Its roof insulation materials should not be below B2; Otherwise, the combustion performance of insulating material should not be below the B1 level. The junction of the roof and wall, the insulation layer around the opening part of roof should use the grade A thermal insulation material to set level fire-fighting belt that width is not less than 500 mm.
Q: How to prolong the furnace age of Induction furnace by using fireproof materials?
magnesia solid materials have thermal endurance and erosion/ performance and its change of temperature is likely to cause cracks. properties of materials (aluminum) in such case have to be taken into consideration.
Q: what's the varieties of thermal insulation material with A level fire?rating?
Inorganic thermal insulation material can do it, such as glass wool,rock wool,foam glass,etc. phenolic foam materials in organic foam material is special. phenolic foam not only has good thermal insulation properties but also can be composited with steel plate and other materials, A class thermal insulation materials that reach A class combustion performance include: rock (mine) wool, foam glass, EVB, etc. thermal insulation materials with A class combustion performance mainly include: phenolic aldehyde,gelatine powder polyphenyl granule, etc. thermal insulation material of fire barrier zone can use rock (mine) wool, foam glass, EVB and other materials with A class combustion performance.
Q: How is the fire endurance of the fireproof paint?
fire endurance of fireproof paint is from 1 to 4 hours. Mechanism: Fireproof paint itself is flame-retardant or non-combustible, protecting the substrate from direct contact with the air,delaying the time for catching fire and reducing the burning speed. fireproof paint decomposes with heat and releases non-combustible inert gas, thining out the flammable gas produced by the protected object, making it difficult to burn or slow down the burning. expansive fireproof paint expands under heat and forms a layer of carbon foam insulation to cover the protected object, delay the heat transfer in the substrate , prevent burning and possible losing of fireproof abilitiy because rising temperature.
Q: How should fireproof building materials be ranked?
5. Civil building 5.1. Fire resistance rating, number of layers and floorage of civil buildings 5.1.1. Fire resistance rating of civil buildings should be classified into four levels of first, second, third and fourth. Unless otherwise specified in the code, the combustion performance and fire endurance of building components with different fire resistance rating should be no less than that of the regulations in Table 5.1.1. Table 5.1.1: Combustion Performance and Fire Endurance (h) of Building Components (Figure) Note: 1. Unless otherwise specified in the Code, the fire resistance rating of the building with wooden pillars as load-bearing and incombustible material as the building wall should be the fourth level; 2. For the suspended ceiling of the building with the second level of fire resistance rating, if it uses non-combustible component, it won't be limited in its fire endurance; 3. For buildings with the second level of fire resistance rating, if it is really difficult for the partition wall of rooms with the area of no less than 100m2 to implement the regulations of the Table, the partition wall can adopt the non-combustible component with fire endurance of no less than 0.3h; 4. For buildings with the first or second level of fire resistance rating, if it is really difficult for the partition wall of both sides of the evacuation walk to implement the regulations of the Table, the partition wall can adopt the non-combustible component with fire endurance of no less than 0.75h. 5. Fire endurance and combustion performance of the residential building component can be implemented in accordance with the provisions of current national standard GB 50368 "Residential Building Code".
Q: What are the characteristics of clay refractory materials?
Clay refractory has excellent performance in anti fatigue. The fatigue strength of the general metal is 50% ~ 40 of the tensile strength, and some composite materials can be as high as 70 ~ 80%. The fatigue fracture of the composite is from the matrix, which is gradually extended to the interface between the fiber and the matrix. Therefore, the composite material has omen before destruction, and it can be checked and remedied. Fiber composite material also has good performance in anti vibration fatigue. The fatigue life of The helicopter rotor made of composite material is longer that made of metal. I hope my answer will help you!
Q: What's the material of fireproof and wear-resisting floor?
It is the kind of special concrete floor, and it should prevent from crash for it will produce fire by friction. It is mostly used for the warehouses storing explosive and inflammable objects and chemical materials. And its production process is the same with that of the common concrete floor, but it uses different material which needs to be the pebbles and sand after processing with marbles and dolomite.
Q: How can the furnace be replaced after the gasifier or water wall is replaced with refractory material?
The simplest is to find a refractory construction unit, should provide you with oven curve.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords