• DIN 24256 Standard Milano Stainless Steel End Suction System 1
  • DIN 24256 Standard Milano Stainless Steel End Suction System 2
  • DIN 24256 Standard Milano Stainless Steel End Suction System 3
DIN 24256 Standard Milano Stainless Steel End Suction

DIN 24256 Standard Milano Stainless Steel End Suction

Ref Price:
get latest price
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

  

 

Horizontal Centrifugal Double Suction Water Pump

1.Structure of Horizontal Centrifugal Double Suction Water Pump Description

 

Horizontal Centrifugal Double Suction Water Pumpis used for transporting pure water (particles density shall be max.1%by volumeand granular size shall be max 0.1mm in dimeter) of the liquids with physical and chemical properties similar to pure water. Type MD pump is applied with wear resist material, especially suitable for mineral drainage. The particles density shall be max. 1.5% (Max. of the granular diameter is 0.5 mm).The liquid temperature ofD, MD pumps shall be lower than 80°C.

 

2.Main Features of the Horizontal Centrifugal Double Suction Water Pump

• Compact structure, good appearance, low construction

•Operation stably, same inlet and outlet

•Convenient installation and maintenance

Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3.Horizontal Centrifugal Double Suction Water Pump Specification

 

Item

Multistage Pump

Multistage Pump

Horizontal Multistage Pump For Pure Water

Model

CMD

Material

Cast iron,Stainless steel

Mode

Horizontal

Color

Blue

Temperature

<=80°c< span=""><>

Seal

packing seal

Theory

Centrifugal Pump

Structure

Multistage Pump

Usage

Water

Power

Electric

Standard or Nonstandard

Standard

Fuel

Diesel

Pressure

High Pressure

Application

Hot and cold pure water

Outlet Diameter

40-500mm

Capacity

6-1250 m3/h

Head

75-1800m

Rotation Speed

1450-2950r/min

Power

5.5-2400kW

Certificate

ISO9001

Feature

High efficiency,Easy maintenance 

 

4.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

Q:Is it normal for my sump pump hole to be empty. No water in there.. ??
If you have had a dry spell or live on the top of a hill, the water table will be lower. A dry sump is normal. If on the other hand there is wet ground around the outside of your basement walls, then you have a drainage problem. The water is not reaching your weeping tiles. Get someone to dig down to the tiles and cover them with your municipality's recommended level of gravel/sand
Q:From the days of the laying of pipe line and trouble is far away, two or more people share the idea of a water pump, controlled by the electromagnetic valve, do not know whether it is feasible, attention should be paid to each of the power may be different phase, and it is the automatic control, automatic switching request all big brother big sister what the solution of power. At the same time, the electromagnetic valve is closed to others. Turn on your own solenoid valve StopThe idea is that each pumping with its own power, so you don't have to worry about sharing electricity.
Each contactor is connected with each power source in the main circuit, and the lower port is connected to the water pump;Control loop, only draw the wiring diagram of A households, households in other similar first power through the control switch in series contactor several other a normally closed contact and then enter the M contactor coil;In water, leading to various water pipes connected with the electromagnetic valve, and the solenoid valve are connected in series and the two contactor normally open contact is connected to the power supply;As long as one of the closed control switch, the pump will run at the same time, using his own power, and this is the other an open pump closed control switch of their own, will not work, the water will not go into his house, the family will not run electricity; only when the first home after closing the control switch second, if still closed control switch, water and electricity will automatically turn to him.Not understood, of course, that there is one drawback, if one is using a pump, a few other can not be used to solve the problems, it is not difficult, is that every installation of a water tank or like a floor, said each install a pressure tank on it
Q:Why should the water pump be opened in time after the pump is started?
The circulating water pump outlet valve is closed when starting, normal after the water outlet valve is opened, I found that, with the valve opening, the current is slowly sinking, you tell me why?, and the other is the opposite of the pump (with the valve opening current increases).
Q:Water pump 50HZ impeller and 60HZ what is different, why not the same?
Water pump 50HZ impeller and 60HZ impeller, its outer diameter is not the same, 60HZ impeller slightly smaller. Because the speed of the impeller of 60HZ is faster, the impeller is a little smaller.Flow rate and speed, impeller diameter into a relationship: Q1/Q2 = n1/n2=D1/D2;Head and speed into two relations: H1/H2 = (n1/n2) 2Motor shaft power and speed into three relations: P1/P2 = (n1/n2) 3From the above deduction, we can know that the motor speed formula is n=60f/p, in which n is motor synchronous speed, and F is supply frequency. P is the pole number of the motor. It is known that the power supply frequency of the motor is proportional to the speed of the f. Therefore, to obtain the same head or flow, high speed, to use a smaller impeller.
Q:Installation position of check valve for water pump
Check valves are normally installed at the pump's exit position!Check valve, also known as check valve, the specific installation needs to determine the direction of the pipeline!If the pipe in the installation position is vertical, you can choose the swing type and pipe type!If the installation position of the pipe is horizontal, you can choose the lifting type!Lift check valve opens and stops at the fastest speed!The swing check valve has the least resistance!The pipe type check valve is mostly in the form of clip type installation, which is suitable for the place where the installation distance is not enough!
Q:the car is a 1973 Pontiac Lemans, 350 V8. Water pump needs to be replaced. It's obviously a mechanical pump that's in there now. I was thinking of getting something with more capacity (to start off) as I feel the car could do with a better cooling system (and I have to get a water pump anyways). I was thinking of getting an electrical pump as that would also free up a bit of power from the engine. From what I gather, by doing this it seems I need to switch to an electrical fan also. Is that the case? Any advice/opinions on electrical systems and set ups? Any recommendations?Thanks in advance to anyone who answers. Much appreciated.
The okorder / Of course, when you are doing this work you want to replace the thermostat, and back flush the rest of the cooling system!
Q:WATER PUMP, HOSES, 1998 TOWN COUNTRY
this is just a rought est. but Parts: water pump $129, Hoses $45 Each, Coolant 2 gal $30, hose clamps $ 5. Labor: water pump 1.2 hours @$89 per labor hour = $106, Hoses .4 hours x 2 hoses = .8 @$89 = $71.20 plus a possible cooling system flush $69. So your looking at around $500 bucks.........that is probably a little high Good luck!
Q:A pump, the flow rate of 30T/H per hour, lift 30 meters, should be allocated more power motor?
Mgh=ptIn 1 hours30*1000*10*30=p*3600P=2500 (W)Therefore, the ideal state should be more than 2500W motorWith all kinds of losses, it is recommended to configure more than 3000W motors
Q:Why does the water pump leak?
The leakage of water pump is caused by many factors:1, the axial movement of the bearings (axial clearance is too large, resulting in static and dynamic ring open. Leak water.2, and automotive cooling liquid is also related to, if the pH of the coolant is large, will corrode the water seal of the surface, resulting in leakage.3, and the user's use is also related, and some users do not properly maintain, add an unclean coolant, resulting in impurities in the coolant. Accumulation in the water seal surface, destroy the water seal torus, forming water leakage.
Q:leaking coolant after the car engine has stoppped
Some water pumps have weeping holes, if water is coming out of those then it is definitely your problem.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords