Characteristics
Nanometer Micropore Insulating Board for Pipe material with an extremely low coefficient of thermal conductivity, i.e. with very good insulating properties.
Nanometer Micropore Insulating Board for Pipe consists of inorganic
silicates. The main constituent is fumed silica, the other components are opacifiers for minimizing infrared radiation.
Nanometer Micropore Insulating Board for Pipe (core material) is not flammable and meets the requirements acc.
Nanometer Micropore Insulating Board for Pipe is heat sealed in a laminated aluminum foil system.
It can be used up to a maximum application temperature of 1100 °C.
Application
Super include back-up insulation in the steel and nonferrous metals industry.
fulfills several functions, such as:
· Precisely controlled energy emission
· Reduction of weight and volume
· Increase of heat retention
· Increased effective volume
Successfully used as insulation material in the following areas:
· Heat treatment systems for metals
· Heat treatment systems for glass
· Fire protection equipment
· Electronic devices
· Measurement equipment
· Plant construction parts
· Parts in the automotive industry
· Chimneys, pipes and diesel exhaust systems
Form of delivery
1. Standard sizes:
· 500 mm * 250 mm * X
· 500 mm * 500 mm * X
· 1000 mm * 500 mm * X
2. Standard thicknesses (X):
· 3 mm, 5 mm, 7 mm, 10 mm
3. Complex geometries and special formats
available on request
Restrictions on Applications
Nanometer Micropore Insulating Board for Pipe is sensitive to all liquids that can wet it, such as water, oil, petroleum spirit, since they can destroy the nanoporous structure.
For the aforementioned reasons, care should be taken not to damage the cover film before or during
installation.
Damage or cut edges must therefore be protection with an Aluminum adhesive tape.
Shelf life
Nanometer Micropore Insulating Board for Pipe ,If properly stored, has an unlimited shelf life and must be handled and stored in dry conditions.
Nanometer Micropore Insulating Board for Pipe is resistant to diffusion by atmospheric humidity (water vapor).
Composition
Silicon dioxide SiO2 approx. 50 %
Zirconium silicate ZrSiO4 approx. 45 %
Others approx. 5 %
Electrical resistance
Panel unhardened
Stored under dry conditions > 2000 MO
Thermal shock resistance
Nanometer Micropore Insulating Board for Pipe is insensitive to high and low temperature thermal shocks.
- Q: I ask, our home is the top floor, the summer is too hot, the walls and roof in addition to the use of insulation board, posted their own kind of tin foil, will not be useful?
- The traditional ceiling color steel tile composite composite 10 cm thick white polystyrene foam insulation board, the insulation effect is not very good, this is because the thermal conductivity of polystyrene foam board is relatively high (thermal conductivity 0.035W / (m · K) above), plus There is a gap between the foam board and the board, the temperature is very serious, the comprehensive thermal conductivity is generally higher than 0.05. The new polyurethane spray insulation material can be directly sprayed on the color steel tile, the thermal conductivity is low, only 0.022-0.024W / (m · K), insulation effect is 2-3 times the polystyrene board, is the insulation of all insulation materials Especially excellent material. Because in the construction of the use of direct spray molding technology, so that the polyurethane foam layer is not the overall burden of sewing the body to form a complete impermeability, fundamentally put an end to the possible deep Sex. Which play a preservative effect.
- Q: Is the thermal conductivity of the vacuum insulated plate used to protect the hot plate method?
- Supplementary feifei answer: 1.10kV to the ground safety distance (vertical) is 6 meters, if the 10kV live line below the minimum safe distance (vertical) is 3 meters, "power facilities protection regulations" provides strict construction, housing construction , If it is temporary construction, in the construction should contact the line unit, you can let them send on-site monitoring construction, but must ensure that the safety distance of 3 meters, than the steel pipe, scaffolding and other metal parts in the construction process should prevent the distance from the live line Excessive discharge causes electric shock. 2. If the use of crane construction, according to the "national shield shield uncle 墉 矫 堕 scared scared off the power grid company safety work procedures" provisions in the 5 meters away, to prevent the arm swing accidentally hit the live conductor. If the 10kV line around (both sides) construction, the safety distance and the vertical distance of the same provisions, if the lifting height beyond the live wire should be taken when the wind caused by the swing caused by electric shock 3. "Construction site temporary safety technical specifications" and " Power facilities protection regulations implementation details "provides only the moving objects, such as wires issued trees, houses and other buildings.
- Q: What brand of refrigerator is using a vacuum insulation board? What kind of insulation board is better? More
- Aluminum generally refers to anodized aluminum, not magnesium alloy. Apple, Dell alien field arc spot some of the old roar M18x (note only M18x is, other models are not) XPS series, all the super class such as Acer hummingbird, Lenovo U300s
- Q: What is the best insulation material? To be waterproof.
- Specifications are generally diameter of 48mm wall thickness of 3.5mm; diameter of the bones of the fen fen shed leters light dog 51 degrees wall thickness of 3.0mm these two kinds of market is currently the country is almost 3900 yuan / ton buckle according to sets of about 5 yuan / set
- Q: External wall insulation material which is good, external wall insulation materials
- Advertisement is here! In fact, the so-called fresh air ventilator is a conceptual product. Ventilation function is very limited, that is difficult to achieve the effect of exchange air. As to say that the answer is more efficient and nonsense. Said the ventilation is limited, because of its small import and export, the amount of ventilation at the end. At the same time the indoor outlet can not guarantee the dirty air away. Said the heat exchange, you can imagine, indoor and outdoor air temperature difference will be more than ten degrees only in a small exchange area and a very short exchange time, in order to replace the hot air into the indoor temperature near the cold air , There is no material to do now.
Send your message to us
VIP Nanometer Micropore Insulating Board for Pipe
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 500 m²
- Supply Capability:
- 10000 m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches