• stainless steel pipe clamp with screw System 1
  • stainless steel pipe clamp with screw System 2
stainless steel pipe clamp with screw

stainless steel pipe clamp with screw

Ref Price:
$0.03 / pc get latest price
Loading Port:
Qingdao
Payment Terms:
TT LC
Min Order Qty:
100 pcs pc
Supply Capability:
300000pcs Per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Usage: Pipe Clamp
Material: steel、matel;Galvanized iron ,stainles
Band width:3mm/20mm
Connection:welding
Model number:As your requirement
Structure:Swivel clamp
Certificate:ISO9001:2008
Feature:
1.Use the open internal and external circle structure,and with screw fixed.It is effectively to solve the problem that when small diameter solft tube connect the hared tube,it is easy appear dead angle,and liquid or gas leakage problem.Easy structure,Easy maked.
2.Edge is no burrfree,it is ability to prevent the tube damaged
3.By a efficiently hydrogen relief treatment,long-term use needn't to worry fracture and other problems
Surface: zinc plated Packaging
4.Accord with DIN3017 Standard.By 48 hours salt and fog test,it has a good corrosion resistance
5.By our last 48 hours elastic test,to insure a high strength mechanical properties.
6.Easy to fix.
Working Temp: -40 ℃ ~ 110 ℃
Size:3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2
Structure: Suspension Clamp and so on On-time shipment and pre-shipment product quality safeguards clamp is mainly used in automobiles,tractors, ships, gasoline engine, and so on each kind of mechanical
device for oil, gas, hydraulic hose connector, various types of
rubber tube interface must join parts fastening.
Detail: plywood case ,pallets or any other package as buyer's requirements
Delivery Detail: about 20-30days
Q:How to use the correct measuring clamp current meter
Using the graphic method of current clampClamp meter AC DC current measurementClamp meter measuring voltage clamp meter surge current measurement
Q:Generator carbon brush sparks, how to deal with?
From the following points: 1. check out whether the brush length is too short to cause the lifeline, the pressure is too small not brush contact ring; 2. check the spring pressure pressure is appropriate, if too small will lead to jump 3. check slip ring brush discharge; surface finish, if too much hair will increase the brush contact resistance of spark; 4. check the rotor electrical resistance, ensure the normal, no inter turn short; 5. check whether the oil bearing gap is too large, resulting in rotor slip ring brush runout, radial runout check slip surface is too large. The brush spark causes sparks; 6., whether the brush is the same as before, the brush has a requirement for the conductive current and the friction speed.
Q:Generator carbon brush fire how to deal with?
Carbon brush and slip ring should be inspected every day. Main inspection items are:(1) the wear length of carbon brush should not exceed 2/3. When the wear length of the carbon brush exceeds the 2/3 (i.e. the top of the carbon brush is at the same level as the top of the brush holder), it must be replaced.(2) carbon brush without sparking. When the carbon brush starts to spark, you must find out the reason and remove it in time.(3) there is no offset slip ring outside the carbon brush, and the edge of the carbon brush is not cracked.(4) the brush brush is connected with brush holder and carbon brush, without heating and touching brush holder.(5) the carbon brush has no pulsation, shaking or sticking in the brush holder.(6) regularly measure the current of each carbon brush evenly with the DC clamp type meter, and measure the carbon brush with the infrared thermometer. If abnormal, it should be replaced in time.(7) the spring pressure is normal, without deformation and fracture. Normal, the pressure on each carbon brush should be uniform and stable, the unit pressure is usually between 1.1kg ~ 2.5kg, the uneven pressure difference between the carbon brush should be less than 5%.(8) the distance between the brush holder and the slip ring conforms to the specified value. Distance between brush holder and slip ring of generator: 2.5 ~ 3 mm, distance between main brush holder and slip ring: 2~4 mm.
Q:How much can the current clamp measure up to? How much accuracy can be achieved?
The range of the general current clamp is at 1000A, and the higher measurement is not suitable. Accuracy is generally not high, can not be used for accurate measurement.
Q:How can the clamp meter measure current and measure overload current?
A gauge for measuring current and how to measure an overload current:1 will be moved to AC current clamp meter gear top position (maximum current clamp meter must be 1.25 times higher than the load current)2 each phase of the current is measured, the current in the rated range is its load current, more than the rated value, the current is its overload current.
Q:Taiyuan Wittel QJR soft start switch current unbalance fault is what reason?
For three-phase current balance clamp current meter, then there may be a fault current transmitter, controller failure, and check the line.
Q:Is there a caliper meter that can measure direct current?
Magnetic balance type current sensor called compensation sensor, namely the primary current Ip generated in the magnetic core premises through a secondary magnetic field coil current magnetic field generated by the compensation, the compensation current of Is accurately reflect the current of primary side Ip, so that the Holzer device is in the working state of zero magnetic flux detection.
Q:Automatic tripping of circuit breaker often, this is why, what to do?
After analyzing the two causes of circuit breaker tripping, some common analysis and treatment methods are summarized. The first is to judge whether it is a circuit problem or a circuit breaker problem. The general process is:Observe whether the burning of a circuit, whether there is odor, the low voltage cabinet within the two control loop whether there is no fault1., when there is a fault point, the switch can be closed, the line problem is explained, and the circuit breaker is irrelevant.2. there is no obvious fault point, in the case of no load, the circuit breaker still can not switch on, it shows that the circuit breaker can not be put into operation, it is the problem of the circuit breaker itself.
Q:I would like to ask the relationship between the power of the water pump motor and the flow of water
The water flow is proportional to the pressure (the pipe diameter is constant), and the pressure is used to control the frequency converter for convenience and automation.
Q:What are the commonly used tools for electrician maintenance?
Electric knife, hammer, bow, flashlight, 30W50W500W electric iron; multimeter, clamp type table, high pressure, low pressure shake table shaking table, ground shaking table, bridge and so on many of you will see what aspects can be, all of the above is the general maintenance electrician general tools.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords