• klikkon brass quick locking pipe clamp System 1
klikkon brass quick locking pipe clamp

klikkon brass quick locking pipe clamp

Ref Price:
$0.03 / pc get latest price
Loading Port:
Qingdao
Payment Terms:
TT LC
Min Order Qty:
100 pcs pc
Supply Capability:
300000pcs Per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Usage: Pipe Clamp
Material: steel、matel;Galvanized iron ,stainles
Band width:3mm/20mm
Connection:welding
Model number:As your requirement
Structure:Swivel clamp
Certificate:ISO9001:2008
Feature:
1.Use the open internal and external circle structure,and with screw fixed.It is effectively to solve the problem that when small diameter solft tube connect the hared tube,it is easy appear dead angle,and liquid or gas leakage problem.Easy structure,Easy maked.
2.Edge is no burrfree,it is ability to prevent the tube damaged
3.By a efficiently hydrogen relief treatment,long-term use needn't to worry fracture and other problems
Surface: zinc plated Packaging
4.Accord with DIN3017 Standard.By 48 hours salt and fog test,it has a good corrosion resistance
5.By our last 48 hours elastic test,to insure a high strength mechanical properties.
6.Easy to fix.
Working Temp: -40 ℃ ~ 110 ℃
Size:3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2
Structure: Suspension Clamp and so on On-time shipment and pre-shipment product quality safeguards clamp is mainly used in automobiles,tractors, ships, gasoline engine, and so on each kind of mechanical
device for oil, gas, hydraulic hose connector, various types of
rubber tube interface must join parts fastening.
Detail: plywood case ,pallets or any other package as buyer's requirements
Delivery Detail: about 20-30days
Q: Generator carbon brush sparks, how to deal with?
Generator carbon brush spark prevention method: every day should be carbon brush and slip ring for inspection1, carbon brush wear length of not more than 2/3. When the wear length of the carbon brush exceeds the 2/3 (i.e. the top of the carbon brush is at the same level as the top of the brush holder), it must be replaced.2, carbon brush without sparking. When the carbon brush starts to spark, you must find out the reason and remove it in time.3, carbon brush without offset outer ring slip phenomenon, carbon brush edge without cracking.4 、 brush carbon brush and brush rack and carbon brush connection is good, no fever and touch brush grip.5, carbon brush in the brush without beating, shaking or stuck.
Q: How to find out the broken capacitor in the three-phase capacitor of the reactive compensation cabinet with the clamp table?
Use clamp meter measuring each capacitance of each phase current, no current is failure, current ratings than too much capacity loss.In fact, do not need to use a clamp meter measurement, the reactive power compensation cabinet in manual operation, and observe the 3 input capacitance by monitoring the current cabinet said the number and capacitance rating (each) to determine whether the sum of.
Q: Measurement of AC and DC dual-use electrical instruments, overload ability of the instrument for?
This is the moving coil instrument, which means the electronic device, do not make a mistake.
Q: What type of gear is used in the caliper 22O line?
Clamp meter is used to measure the current card line, 220V line to exchange files, if you do not know how much current, first hit the high-end position, you take a photo of the best clamp meter decreased gradually to an appropriate position
Q: What instrument can be used to detect high power?
You do not use the high-power appliances can not be found, but if you are using, he is able to detect with a variety of instruments, it can check through the circuit branch to find the location of the use of electrical appliances, and then focus on inspection.
Q: How to use the pliers?
When the utility model is used, the movable iron core is opened by pressing the handle, and the conducting wire of the current to be measured is put into the jaw, and the iron core is closed after being released. The current through the wire equivalent transformer primary, secondary inductive current, current meter is connected to the secondary coil, so that the secondary coil current, form scale is good has returned to the current scale, which can indicate the value of measured current. A table is convenient to use, but the accuracy is not high.
Q: A table can be used to measure the DC current?
The current transformer produced by the clamp meter, can only measure the AC current, accurate measurement of sine wave current near 50Hz only, cannot measure the DC current.
Q: 20kW motor running for some time will trip what is the reason?
Air capacity is small, the fever will trip
Q: What's the reason for the leak on the air conditioner? The pipes outside are changed, but the air conditioner is nearby
Sometimes the ventilation pipe air conditioning installation company installed in place, the connection is not smooth, the vent seal will cause the air outlet panel dewing phenomenon. Of course, the central air conditioning outlet drip water, mostly by the first two reasons.
Q: Use clamp ammeters, wire requirements will be placed in the window center. Why is this?
The measured voltage clamp meter shall not exceed the values marked on the ground, otherwise easy to cause the accident, or cause the risk of electric shock.