Split-type DC Charging Equipment is Used for Electric Vehicle
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 unit
- Supply Capability:
- 10000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Split-type DC Charging Equipment
Split-type DC charging equipment is used for electric vehicle charge power supply of centralized charging network. It can deploy charging network rapidly and effectively, providing high-power charging service for electric vehicles. It consists of rectifier cabinet and outdoor charging terminals. Each rectifier cabinet can be installed maximum 25pcs rectifier modules. It is applied to be fit for charging station and the operation of enterprises’ parking lot.
Split-type DC charger I series: Output voltage range DC200V ~ 400V settable, the maximum output power of single unit is 150KW.
Split-type DC charger II series: Output voltage range DC400V ~ 700V settable, the maximum output power of single unit is 150KW.
●Modular design, full protection:AC input over-voltage, under-voltage protection
●Output over-voltage, output short-circuit protection
●Over-current protection
●Over-temperature protection
●Overload protection
●Reverse-battery protection,impulse current surge protection etc
Model | EVDC-40KW-4 EVDC-40KW-7 | EVDC-50KW-4 EVDC-50KW-7 | EVDC-80KW-4 EVDC-80KW-7 | EVDC-150KW-4 EVDC-150KW-7 |
Input | ||||
Input voltage(V) | 323~475(three phase) | |||
Input current(A) | ≤100 | ≤110 | ≤220 | ≤300 |
Input frequency(Hz) | 45~65 | |||
Efficiency | ≥95% | |||
Power factor | ≥0.99 | |||
Input THD | ||||
Output | ||||
Output voltage range | 400Vdc series:200~400Vdc | |||
700Vdc series:300~700Vdc | ||||
Rated output current(A) 400V | 105 | 125 | 210 | 375 |
Rated output current (A) 700V | 60 | 75 | 120 | 212 |
Max. output current(A) 400V | 112 | 133 | 224 | 400 |
Max. output current(A) 700V | 65 | 81 | 130 | 225 |
Soft start time(s) | 3~8 | |||
Output constant-current range | 10%~100% | |||
Voltage regulation accuracy | ≤±0.2% | |||
Stable current precision | ≤±0.5% | |||
Ripple coefficient (peak value) | ≤1% | |||
Current-sharing unbalanced degree | ≤±3%,(50%~100%rated load) | |||
Noise(dB) | <65 | |||
Protection | ||||
Output short-circuit protection | Retraction current≤40%Io, Resettable | |||
Output over-voltage protection | No output after protection, Non-recoverable (require manual recovery) | |||
Input over/under voltage protection | No output after protection. Resettable | |||
Phase-lack protection | No output after protection. Resettable | |||
Over-temperature protection | No output after protection. Resettable | |||
Charging configuration and standard | ||||
Charging plug number | / | |||
Charging cable length(m) | / | |||
Communication protocol standard | GB/T 27930-2011, NB/T 33003-2010 | |||
Charger standard | NB/T 33001-2010,NB/T 33008.1-2013 | |||
Environment | ||||
Working Temperature (℃) | -20~+50 | |||
Storage temperature(℃) | -40~+80 | |||
Relative humidity | ≤95% | |||
Atmospheric pressure(kPa) | 70~106 | |||
Mechanical parameter | ||||
Dimensions(H*W*D)(mm) | 1400*600*600 | 2000*600*600 | ||
Weight(kg) | ≤170 | ≤270 | ||
IP degree | IP31 |
· Q. What is an UPS and What it is for ?
An uninterruptible power supply (UPS) is a device that allows your computer or telephone switch or critical equipement to keep running for at least a short time or longer time when the primary power source is lost. It also provides protection from power surges, spikes, brownouts, interference and other unwanted problems on the supported equipment.
· Q. How long the UPS to run when power goes?
This can take 3 paths.
1.You can pick a UPS that is rated for pretty much the full VA you need so it will be running at 100% of capability and will thus last 'n' minutes.
2.You can pick a UPS that is rated at a much higher VA value than you really need so, for example, is running at 50% of capability and will thus last for longer than the UPS from option 1.
3.You can use extra external battery packs to run for longer. If charging capability allows, the more and the bigger batteries you take with, the longer time UPS runs.
or using a generator after about 6 hours, it will be more cost-effective, with a short runtime UPS to bridge the generator start-up gap.
Send your message to us
Split-type DC Charging Equipment is Used for Electric Vehicle
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 unit
- Supply Capability:
- 10000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords