Solar MPPT Controler LCD and LEDs Equipment Integrity
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 50 unit
- Supply Capability:
- 10000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.MPPT charge mode,conversion efficiency up to 99%,can save 30%~60% of the power than traditional controller.
2.With high efficient MPPT operation scheme and adopting TI28035 chip,make the Solar panels utilization rate up to 99%.
3.Intelligent design,the device can be upgraded online,customers enjoy the lifelong upgrade service.
4.Compliance with the 2002/95/EC environment protecting demand,doesn't include the Cadmium, hydride and fluoride
5.Adopting the well-known brand components,the devices can suffer the temperature not less than 105℃.The service life is designed to extend to 10 years in theory.
6.Charge mode: three stages (constant current, constant voltage,floating charge)
7.12V/24V/48V/96V system auto recognize for easy control.
8.Nominal maximum solar input is DC 300V
9.Connected Battery Type choosing: Sealed lead acid, vented, Gel, NiCd battery. Other types of the batteries can also be defined.
10. LCD and LEDs show all kinds of parameter like products model, PV input voltage,battery type, battery voltage,charge current,charge power,work condition,and also can add customers'company name and website.
11. Communication Port.RS232 communication can provide communication protocol, This make the unified and integrated management more convenient to customers.
12. With providing a Microsoft by connecting with PC that can show the working state and all parameters in 11 languages.
13. Extensible LAN remote control.
14.Equipment integrity: controller+CD-ROM(microcomputer software) + communication wire+operation manual+Anderson terminals;
15.CE,ROHS,FCC,PSE certifications approved.The device also can support to pass the other certifications.
Model: XD-T-DC12V/24V/48V/96V--series | 20A | 30A | |||||
Charge Mode | Maximum Power Point Tracking | ||||||
Method | 3 stages: constant current(MPPT),constant voltage,floating charge | ||||||
System Type | DC12V/24V/48V | Automatic recognition | |||||
System Voltage | 12V system | DC9V~DC15V | |||||
24V system | DC18V~DC30V | ||||||
48Vsystem | DC36V~DC60V | ||||||
96Vsystem | DC72V~DC120V | ||||||
Soft Start Time | 12V/24V/48V/96V system | ≤10S | |||||
Dynamic Response Recovery Time | 12V/24V/48V/96V system | 500us | |||||
Conversion Efficiency | 12V/24V/48V/96V system | ≥96.5%,≤99% | |||||
PV Modules Utilization Rate | 12V/24V/48V/96V system | ≥99% | |||||
Input Characteristics | |||||||
MPPT Working Voltage and Range | 12V system | DC18V~DC150V | |||||
24V system | DC34~DC150V | ||||||
48V system | DC65~DC150V | ||||||
96V system | DC125~DC300V | ||||||
Low Voltage Input Protection Point | 12V system | DC16V | |||||
24V system | DC30V | ||||||
48V system | DC60V | ||||||
96V system | DC120V | ||||||
Low Voltage Input Recovery Point | 12V system | DC22V | |||||
24V system | DC34V | ||||||
48V system | DC65V | ||||||
96V system | DC 125V | ||||||
Max DC Voltage | 12V/24V/48V system | DC160V | |||||
96V system | DC300V | ||||||
Input Overvoltage Protection Point | 12V/24V/48V system | DC150V | |||||
96V system | DC300V | ||||||
Input Overvoltage Recovery Point | 12V/24V/48V system | DC145V | |||||
96V system | DC295V | ||||||
Max. PV Power | 12V system | 280W | 450W | ||||
24V system | 560W | 850W | |||||
48V system | 1120W | 1700W | |||||
96V system | 2240W | 3400W | |||||
Output Characteristics | |||||||
Selectable Battery Types (Default type is GEL battery) | 12V/24V/48V/96V system | Sealed lead acid, vented, Gel, NiCd battery | |||||
Constant Voltage | 12V/24V/48V /96V system | Please check the charge voltage according to the battery type form. | |||||
Floating Charge Voltage | 12V/24V/48V/96V system | ||||||
Over Charge Protection Voltage | 12V system | 14.6V | |||||
24V system | 29.2V | ||||||
48V system | 58.4V | ||||||
96V system | 116.8V | ||||||
Rated Output Current | 12V/24V/48V/96V system | 20A | 30A | ||||
Current-limiting Protection | 12V/24V/48V /96V system | 25A | 35A | ||||
Temperature Factor | 12V/24V/48V/96V system | ±0.02%/℃ | |||||
Temperature Compensation | 12V/24V/48V/96V system | 14.2V-(The highest temperature-25℃)*0.3 | |||||
Output Ripples(peak) | 12V/24V/48V/96V system | 200mV | |||||
Output Voltage Stability Precision | 12V/24V/48V/96V system | ≤±1.5% | |||||
Display | |||||||
LCD display | Input,output parameter and output power etc | ||||||
LED display | 3 LEDs indicates:Fault indicate light,chargeindicate light, | ||||||
Software Control through PC(communication port) | RS232 (matching) or LAN(optional) | ||||||
Protection | |||||||
Input Low Voltage Protection | Check the input characteristics | ||||||
Input Overvoltage Protection | Check the input characteristics | ||||||
Input Polarity Reversal Protection | yes | ||||||
Output Overvoltage Protection | Check the output characteristics | ||||||
Output Polarity Reversal Protection | yes | ||||||
Short-circuit Protection | Recover after eliminating the Short-circuitfault,no problem for | ||||||
Temperature Protection | 95℃ | ||||||
Temperature Rise Protection | Above 85℃,decrease the outputpower,decrease 3A per degree. | ||||||
Other Parameters | |||||||
Noise | ≤40dB | ||||||
Thermal methods | Forced air cooling,fan speed rate regulated bytemperature,when inner temperature is toolow,fan ran slowly or stop; | ||||||
Components | World brand raw materials. Compliance with EU standards. | ||||||
Smell | |||||||
Environment Protection | Meet the 2002/95/EC,no cadmium hydride and fluoride | ||||||
Physical | |||||||
Measurement DxWxH(mm) | 270*185*90 | ||||||
Carton Size | 330*245*150 | ||||||
N.G(kg) | 3 | ||||||
G.N(kg) | 4 | ||||||
Color | Blue/Green (optional) | ||||||
Safety | CE,RoHS, PSE,FCC | ||||||
EMC | EN61000 | ||||||
Type of Mechanical Protection | IP21 | ||||||
Environment | |||||||
Humidity | 0~90%RH ( no condense) | ||||||
Altitude | 0~3000m | ||||||
Operating Temperature | -20℃ ~ +40℃ | ||||||
Storage Temperature | -40℃ ~ +75℃ | ||||||
Atmospheric Pressure | 70~106kPa | ||||||
Model: XD-T-DC12V/24V/48V--series | 40A | 50A | 60A | |
Charge Mode | Maximum Power Point Tracking | |||
Method | 3 stages: constant current(MPPT),constant voltage,floating charge | |||
System Type | DC12V/24V/48V | Automatic recognition | ||
System Voltage | 12V system | DC9V~DC15V | ||
24V system | DC18V~DC30V | |||
48Vsystem | DC36V~DC60V | |||
Soft Start Time | 12V/24V/48Vsystem | ≤10S | ||
Dynamic Response Recovery Time | 12V/24V/48Vsystem | 500us | ||
Conversion Efficiency | 12V/24V/48Vsystem | ≥96.5%,≤99% | ||
PV Modules Utilization Rate | 12V/24V/48Vsystem | ≥99% | ||
Input Characteristics | ||||
MPPT Working Voltage and Range | 12V system | DC18V~DC150V | ||
24V system | DC34~DC150V | |||
48V system | DC65~DC150V | |||
Low Voltage Input Protection Point | 12V system | DC16V | ||
24V system | DC30V | |||
48V system | DC60V | |||
Low Voltage Input Recovery Point | 12V system | DC22V | ||
24V system | DC34V | |||
48V system | DC65V | |||
Max DC Voltage | 12V/24V/48V system | DC160V | ||
Input Overvoltage Protection Point | 12V/24V/48V system | DC150 | ||
Input Overvoltage Recovery Point | 12V/24V/48V system | DC145V | ||
Max. PV Power | 12V system | 570W | 700W | 900W |
24V system | 1130W | 1400W | 1700W | |
48V system | 2270W | 2800W | 3400W | |
Output Characteristics | ||||
Selectable Battery Types (Default type is GEL battery) | 12V/24V/48Vsystem | Sealed lead acid, vented, Gel, NiCd battery | ||
Constant Voltage | 12V/24V/48V system | Please check the charge voltage according to the battery type form. | ||
Floating Charge Voltage | 12V/24V/48V system | |||
Over Charge Protection Voltage | 12V system | 14.6V | ||
24V system | 29.2V | |||
48V system | 58.4V | |||
Rated Output Current | 12V/24V/48V system | 40A | 50A | 60A |
Current-limiting Protection | 12V/24V/48V system | 44A | 55A | 66A |
Temperature Factor | 12V/24V/48V system | ±0.02%/℃ | ||
Temperature Compensation | 12V/24V/48V system | 14.2V-(The highest temperature-25℃)*0.3 | ||
Output Ripples(peak) | 12V/24V/48V system | 200mV | ||
Output Voltage Stability Precision | 12V/24V/48V system | ≤±1.5% | ||
Display | ||||
LCD display | Input,output parameter and output power etc | |||
LED display | 3 LEDs indicates:Fault indicate light,chargeindicate light, | |||
Software Control through PC(communication port) | RS232 (matching) or LAN(optional) | |||
Protection | ||||
Input Low Voltage Protection | Check the input characteristics | |||
Input Overvoltage Protection | Check the input characteristics | |||
Input Polarity Reversal Protection | yes | |||
Output Overvoltage Protection | Check the output characteristics | |||
Output Polarity Reversal Protection | yes | |||
Short-circuit Protection | Recover after eliminating the Short-circuitfault,no problem for | |||
Temperature Protection | 95℃ | |||
Temperature Rise Protection | Above 85℃,decrease the outputpower,decrease 3A per degree. | |||
Other Parameters | ||||
Noise | ≤40dB | |||
Thermal methods | Forced air cooling,fan speed rate regulated bytemperature,when inner temperature is toolow,fan ran slowly or stop; | |||
Components | World brand raw materials. Compliance with EU standards. | |||
Smell | ||||
Environment Protection | Meet the 2002/95/EC,no cadmium hydride and fluoride | |||
Physical | ||||
Measurement DxWxH(mm) | 270*185*90 | |||
Carton Size | 330*245*150 | |||
N.G(kg) | 3 | |||
G.N(kg) | 3.6 | |||
Color | Blue/Green (optional) | |||
Safety | CE,RoHS, PSE,FCC | |||
EMC | EN61000 | |||
Type of Mechanical Protection | IP21 | |||
Environment | ||||
Humidity | 0~90%RH ( no condense) | |||
Altitude | 0~3000m | |||
Operating Temperature | -20℃ ~ +40℃ | |||
Storage Temperature | -40℃ ~ +75℃ | |||
Atmospheric Pressure | 70~106kPa |
Warranty
provides a 1~3 year limited warranty (“Warranty”) against defects in materials and workmanship for its Uninterruptible power supply, Power inverter/chargers, Solar charge controllers, Battery Products (“Product”).
The term of this Warranty begins on the Product(s) initial purchase date, or the date of receipt of the Product(s) by the end user, whichever is later. This must be indicated on the invoice, bill of sale, and/or warranty registration card submitted to us. This Warranty applies to the original Product purchaser, and is transferable only if the Product remains installed in the original use location.
FAQ
1. What if the product has problem during Warranty?
--- We will, at its option, repair or replace the defective product free of charge, provided product defect within the Warranty Period for your product.
2. What kind of service can I get when I need help or service?
---If your product requires troubleshooting or warranty service, contact your merchant. If you are unable to contact your merchant, or the merchant is unable to provide service, contact us directly at the number listed on the website.
3. How do I install my system?
---A solar backup inverter is connected to a home electric system , we will supply detailed installation manual and videos for our customers .
Send your message to us
Solar MPPT Controler LCD and LEDs Equipment Integrity
- Loading Port:
- Guangzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 50 unit
- Supply Capability:
- 10000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products