• Solar Battery REX Series for Solar and Wind Power REX-2000 System 1
  • Solar Battery REX Series for Solar and Wind Power REX-2000 System 2
  • Solar Battery REX Series for Solar and Wind Power REX-2000 System 3
  • Solar Battery REX Series for Solar and Wind Power REX-2000 System 4
  • Solar Battery REX Series for Solar and Wind Power REX-2000 System 5
  • Solar Battery REX Series for Solar and Wind Power REX-2000 System 6
Solar Battery REX Series for Solar and Wind Power REX-2000

Solar Battery REX Series for Solar and Wind Power REX-2000

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
5000000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Solar Battery REX Series Introduction

REX battery  is designed for Renewable Energy Sources such as  Solar and Wind Power. REX protects  our environment using Green Technology and  benefits the World's Urban  and Rural Population by Generating  Power Economically from a Clean Source  of Energy.

REX is a product developed  by our R&D with  an " eXtra" in Performance  and Life Span.
The REX series batteries are ensured the quality with  QA  system according to the ISO9001&ISO14001 standard.

 

 

Solar Battery REX Series for Solar and Wind Power REX-2000

Solar Battery REX Series for Solar and Wind Power REX-2000

Solar Battery REX Series for Solar and Wind Power REX-2000

Solar Battery REX Series Features and Benefits

  • Long life design for both  cyclic and float applications

  • Superb security and  reliability

  • Robust design inside and out

  • Excellent deep discharge  recovery fast recharge performance

  • Extra long back-up times

  • More cost effective than  nearest equivalent


Type:

  REX-2000

Voltage:

  2V

Nominal Capacity:

  2000Ah(C10)  2000Ah(10 hours rate:)

Length:

  235mm

Width:

  443mm

Height:

  502mm

Height  with termial:

  514mm

Weight:

  155Kg

Solar Battery REX Series Compliant  Standards

  • IEC60896-21/22

  • IEC61427

  • BS6290 part 4

  • Telcordia SR4228

  • Eurobat guide

  • UL

  • Manufactured under system  ISO9001(TUV) and ISO14001

Solar Battery REX Series  Battery  Installation Compliant with

  • EN 50272-2 or local  equivalents

Solar Battery REX Series Main  Applications

  • Renewable energy source such  as solar and wind power

  • Telecom exchange and transmission  system

  • Mobile communication system

  • Power plant and power  transformer system

  • Navigation aid signaling  system

  • Radio and broadcasting  station

  • Emergency lighting system

  • Other standby, cyclic system

Solar Battery REX Series Installation  and Operation

  • Recommended float charge voltage  2.27V per cell at 25oC
     compensation in function of temperature -3mV/oC/cell

  • Cycle and equalize charge  voltage: 2.35V per cell at 25oC
     compensation in function of temperature -5mV/oC/cell

  • CC-CV charge current  unlimited, otherwise 150A  max. if T>25oC

  • Preferred operating  temperature range 15oC to 25oC(68oF to 77oF)

  • Maximum operating  temperature range -40oC to 50oC(-40oF to 122oF)

  • A separate battery room is  not necessary

  • Reduced maintenance no water  addition required.

  • Design float life: 20 years at 25oC (77oF)

Solar Battery REX Series Construction

  • Positive plate --- Reinforced grids in a corrosion-resistant pure  lead, high tin, low calcium alloy

  • Negative plate --- Lead-calcium alloy grid

  • Separator ---  High  density microporous glass mat with low electrical resistance

  • Container & lid --- High strength ABS(HB). Optional flame retardant F V-0 and halogen-free versions available

  • Electrolyte --- Sulphuric acid with a density of 1.28g/ml  absorbed in AGM

  • Terminal design --- Patented leak resistant seal configuration with  brass insert

  • Safety valve --- Calibrated opening pressure , the valve  equipped with flame arrestors for  increased operational safety and service life.

 FAQ

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

What is battery cycle life?

One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .

 

Q:What is the difference between a maintenance-free battery and a conventional battery?
As a result of maintenance-free batteries using lead-calcium alloy grille, the amount of water generated when charging less water evaporation, coupled with the shell with a sealed structure, the release of sulfuric acid gas is also very small, so it compared with the traditional battery, With no need to add any liquid, the wiring pile head, wire and body corrosion less anti-overcharge capacity, starting current, power storage time is long, by the car people welcome.
Q:What kind of battery is divided into?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water. It also has a shock, high temperature, small size, self-discharge characteristics of the general life is generally ordinary Twice the battery. There are two kinds of maintenance-free batteries on the market.
Q:How to determine the battery is good or bad?
If less than 9V but the pointer is in a certain value does not move that the battery is in a state of loss, need to add charge.
Q:Lead-acid battery how to maintain?
Along the battery cover on the exhaust hole, open the battery cover plate, some of the battery cover is APS adhesive, and some batteries are buckle connection, pay attention to open the cover when the cover plate The At this time you can see the six exhaust raft rubber cap.
Q:How does the battery increase the voltage?
You can use the same battery in series, with 5 12v battery in series becomes 60v, if you need the current is relatively small, you can use DC-DC module to 12v voltage rise to 60v.
Q:How does battery activation work?
Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.
Q:What are the hazards of battery over discharge?
The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
Q:What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q:How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q:Battery 200ah / 104 what does that mean?
Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords