Solar Battery REX Series Introduction
REX battery is designed for Renewable Energy Sources such as Solar and Wind Power. REX protects our environment using Green Technology and benefits the World's Urban and Rural Population by Generating Power Economically from a Clean Source of Energy.
REX is a product developed by our R&D with an " eXtra" in Performance and Life Span.
The REX series batteries are ensured the quality with QA system according to the ISO9001&ISO14001 standard.
Solar Battery REX Series Features and Benefits
Long life design for both cyclic and float applications
Superb security and reliability
Robust design inside and out
Excellent deep discharge recovery fast recharge performance
Extra long back-up times
More cost effective than nearest equivalent
Type: | REX-1000 | |
Voltage: | 2V | |
Nominal Capacity: | 1000Ah(C10) | 1000Ah(10 hours rate:) |
Length: | 231mm | |
Width: | 282mm | |
Height: | 396mm | |
Height with termial: | 408mm | |
Weight: | 76Kg |
Solar Battery REX Series Compliant Standards
IEC60896-21/22
IEC61427
BS6290 part 4
Telcordia SR4228
Eurobat guide
UL
Manufactured under system ISO9001(TUV) and ISO14001
Solar Battery REX Series Battery Installation Compliant with
EN 50272-2 or local equivalents
Solar Battery REX Series Main Applications
Renewable energy source such as solar and wind power
Telecom exchange and transmission system
Mobile communication system
Power plant and power transformer system
Navigation aid signaling system
Radio and broadcasting station
Emergency lighting system
Other standby, cyclic system
Solar Battery REX Series Installation and Operation
Recommended float charge voltage 2.27V per cell at 25oC
compensation in function of temperature -3mV/oC/cellCycle and equalize charge voltage: 2.35V per cell at 25oC
compensation in function of temperature -5mV/oC/cellCC-CV charge current unlimited, otherwise 150A max. if T>25oC
Preferred operating temperature range 15oC to 25oC(68oF to 77oF)
Maximum operating temperature range -40oC to 50oC(-40oF to 122oF)
A separate battery room is not necessary
Reduced maintenance no water addition required.
Design float life: 20 years at 25oC (77oF)
Solar Battery REX Series Construction
Positive plate --- Reinforced grids in a corrosion-resistant pure lead, high tin, low calcium alloy
Negative plate --- Lead-calcium alloy grid
Separator --- High density microporous glass mat with low electrical resistance
Container & lid --- High strength ABS(HB). Optional flame retardant F V-0 and halogen-free versions available
Electrolyte --- Sulphuric acid with a density of 1.28g/ml absorbed in AGM
Terminal design --- Patented leak resistant seal configuration with brass insert
Safety valve --- Calibrated opening pressure , the valve equipped with flame arrestors for increased operational safety and service life.
FAQ
How long a battery can last?
The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.
Do batteries self-discharge when not in use?
All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.
What is battery cycle life?
One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .
- Q: How to repair the battery?
- To the battery in accordance with the 0.1C current discharge, record the discharge time. Its discharge current multiplied by the number of hours of time, is the battery repair capacity. If the Chongqing battery capacity to reach the nominal capacity of more than 70%, the end of the repair.
- Q: How is the capacity of the battery defined?
- General circuit has a battery protection circuit, once the battery voltage is less than 10.8V will automatically cut off the electricity to prevent the battery because of over-discharge and damage. (Nominal value of 12V battery internal six cell grid) with the battery discharge current multiplied by the discharge time to express how much energy the battery can store, is a very image of a measure. The greater the value of the battery, indicating that the battery can store more energy. But does not mean that the battery can use such a large current discharge.
- Q: What are the technical parameters of the battery?
- Usually the capacity of the power supply is expressed by kV · A or kW. However, as a power supply VRLA battery, the use of security (A · h) that its capacity is more accurate.
- Q: How to deal with waste batteries?
- The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.
- Q: What are the hazards of battery over discharge?
- The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
- Q: Maintenance-free battery how to detect it?
- When using a maintenance-free battery, it is easy to think that maintenance-free is the idea that no maintenance is required. Maintenance-free Although maintenance costs and times can be reduced, but for the appearance of the clean-up is essential, so that "maintenance-free" more point to the battery inside.
- Q: What battery does the van use?
- The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
- Q: 80ah how much battery storage capacity?
- Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
- Q: How does the battery increase the voltage?
- You can use the same battery in series, with 5 12v battery in series becomes 60v, if you need the current is relatively small, you can use DC-DC module to 12v voltage rise to 60v.
- Q: Battery 200ah / 104 what does that mean?
- This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Send your message to us
Solar Battery REX Series for Solar and Wind Power REX-1000
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 unit
- Supply Capability:
- 5000000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords