Solar Battery REX Series for Solar and Wind Power REX-800
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 unit
- Supply Capability:
- 5000000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Solar Battery REX Series Introduction
REX battery is designed for Renewable Energy Sources such as Solar and Wind Power. REX protects our environment using Green Technology and benefits the World's Urban and Rural Population by Generating Power Economically from a Clean Source of Energy.
REX is a product developed by our R&D with an " eXtra" in Performance and Life Span.
The REX series batteries are ensured the quality with QA system according to the ISO9001&ISO14001 standard.
Solar Battery REX Series Features and Benefits
Long life design for both cyclic and float applications
Superb security and reliability
Robust design inside and out
Excellent deep discharge recovery fast recharge performance
Extra long back-up times
More cost effective than nearest equivalent
Type: | REX-800 | |
Voltage: | 2V | |
Nominal Capacity: | 800Ah(C10) | 800Ah(10 hours rate:) |
Length: | 231mm | |
Width: | 231mm | |
Height: | 396mm | |
Height with termial: | 408mm | |
Weight: | 62Kg |
Solar Battery REX Series Compliant Standards
IEC60896-21/22
IEC61427
BS6290 part 4
Telcordia SR4228
Eurobat guide
UL
Manufactured under system ISO9001(TUV) and ISO14001
Solar Battery REX Series Battery Installation Compliant with
EN 50272-2 or local equivalents
Solar Battery REX Series Main Applications
Renewable energy source such as solar and wind power
Telecom exchange and transmission system
Mobile communication system
Power plant and power transformer system
Navigation aid signaling system
Radio and broadcasting station
Emergency lighting system
Other standby, cyclic system
Solar Battery REX Series Installation and Operation
Recommended float charge voltage 2.27V per cell at 25oC
compensation in function of temperature -3mV/oC/cellCycle and equalize charge voltage: 2.35V per cell at 25oC
compensation in function of temperature -5mV/oC/cellCC-CV charge current unlimited, otherwise 150A max. if T>25oC
Preferred operating temperature range 15oC to 25oC(68oF to 77oF)
Maximum operating temperature range -40oC to 50oC(-40oF to 122oF)
A separate battery room is not necessary
Reduced maintenance no water addition required.
Design float life: 20 years at 25oC (77oF)
Solar Battery REX Series Construction
Positive plate --- Reinforced grids in a corrosion-resistant pure lead, high tin, low calcium alloy
Negative plate --- Lead-calcium alloy grid
Separator --- High density microporous glass mat with low electrical resistance
Container & lid --- High strength ABS(HB). Optional flame retardant F V-0 and halogen-free versions available
Electrolyte --- Sulphuric acid with a density of 1.28g/ml absorbed in AGM
Terminal design --- Patented leak resistant seal configuration with brass insert
Safety valve --- Calibrated opening pressure , the valve equipped with flame arrestors for increased operational safety and service life.
FAQ
How long a battery can last?
The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.
Do batteries self-discharge when not in use?
All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.
What is battery cycle life?
One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .
- Q: How to repair the battery?
- Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
- Q: How is the capacity of the battery defined?
- 100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
- Q: What are the hazards of battery over discharge?
- Excessive discharge can seriously damage the battery's electrical performance and cycle life.
- Q: What are the advantages of maintenance-free batteries?
- The advantage of a maintenance-free battery is that the service life is twice as long as the dry battery! And in the use of the process without maintenance! The voltage is also relatively stable.
- Q: What is the meaning of the battery above 12v65Ah?
- Voltage 12V, current 65AH, that is the capacity of 65A. (A is the unit of current. H is the time unit)
- Q: How should the battery be well maintained?
- Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
- Q: How does the battery increase the voltage?
- You can use the same battery in series, with 5 12v battery in series becomes 60v, if you need the current is relatively small, you can use DC-DC module to 12v voltage rise to 60v.
- Q: What is a maintenanceable battery?
- It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
- Q: How does battery activation work?
- If you are talking about dry batteries, that is, to add sulfuric acid can use the battery (commonly known as water bottles), then it is because the long-term storage so that a high degree of oxidation of the negative board, plus acid will be a high temperature, Low, you can add acid in the pool after the addition of a small current for a long time to charge, you can solve. Generally with 0.05C charge to 3 times can be.
- Q: Lead-acid battery how to maintain?
- Along the battery cover on the exhaust hole, open the battery cover plate, some of the battery cover is APS adhesive, and some batteries are buckle connection, pay attention to open the cover when the cover plate The At this time you can see the six exhaust raft rubber cap.
Send your message to us
Solar Battery REX Series for Solar and Wind Power REX-800
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 unit
- Supply Capability:
- 5000000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords