Solar Battery REX Series for Solar and Wind Power REX-800
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 unit
- Supply Capability:
- 5000000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Solar Battery REX Series Introduction
REX battery is designed for Renewable Energy Sources such as Solar and Wind Power. REX protects our environment using Green Technology and benefits the World's Urban and Rural Population by Generating Power Economically from a Clean Source of Energy.
REX is a product developed by our R&D with an " eXtra" in Performance and Life Span.
The REX series batteries are ensured the quality with QA system according to the ISO9001&ISO14001 standard.
Solar Battery REX Series Features and Benefits
Long life design for both cyclic and float applications
Superb security and reliability
Robust design inside and out
Excellent deep discharge recovery fast recharge performance
Extra long back-up times
More cost effective than nearest equivalent
Type: | REX-800 | |
Voltage: | 2V | |
Nominal Capacity: | 800Ah(C10) | 800Ah(10 hours rate:) |
Length: | 231mm | |
Width: | 231mm | |
Height: | 396mm | |
Height with termial: | 408mm | |
Weight: | 62Kg |
Solar Battery REX Series Compliant Standards
IEC60896-21/22
IEC61427
BS6290 part 4
Telcordia SR4228
Eurobat guide
UL
Manufactured under system ISO9001(TUV) and ISO14001
Solar Battery REX Series Battery Installation Compliant with
EN 50272-2 or local equivalents
Solar Battery REX Series Main Applications
Renewable energy source such as solar and wind power
Telecom exchange and transmission system
Mobile communication system
Power plant and power transformer system
Navigation aid signaling system
Radio and broadcasting station
Emergency lighting system
Other standby, cyclic system
Solar Battery REX Series Installation and Operation
Recommended float charge voltage 2.27V per cell at 25oC
compensation in function of temperature -3mV/oC/cellCycle and equalize charge voltage: 2.35V per cell at 25oC
compensation in function of temperature -5mV/oC/cellCC-CV charge current unlimited, otherwise 150A max. if T>25oC
Preferred operating temperature range 15oC to 25oC(68oF to 77oF)
Maximum operating temperature range -40oC to 50oC(-40oF to 122oF)
A separate battery room is not necessary
Reduced maintenance no water addition required.
Design float life: 20 years at 25oC (77oF)
Solar Battery REX Series Construction
Positive plate --- Reinforced grids in a corrosion-resistant pure lead, high tin, low calcium alloy
Negative plate --- Lead-calcium alloy grid
Separator --- High density microporous glass mat with low electrical resistance
Container & lid --- High strength ABS(HB). Optional flame retardant F V-0 and halogen-free versions available
Electrolyte --- Sulphuric acid with a density of 1.28g/ml absorbed in AGM
Terminal design --- Patented leak resistant seal configuration with brass insert
Safety valve --- Calibrated opening pressure , the valve equipped with flame arrestors for increased operational safety and service life.
FAQ
How long a battery can last?
The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.
Do batteries self-discharge when not in use?
All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.
What is battery cycle life?
One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .
- Q: How is the capacity of the battery defined?
- General circuit has a battery protection circuit, once the battery voltage is less than 10.8V will automatically cut off the electricity to prevent the battery because of over-discharge and damage. (Nominal value of 12V battery internal six cell grid) with the battery discharge current multiplied by the discharge time to express how much energy the battery can store, is a very image of a measure. The greater the value of the battery, indicating that the battery can store more energy. But does not mean that the battery can use such a large current discharge.
- Q: How to determine the battery is good or bad?
- Instrument test: the general use of battery discharge tester, the test instrument two positive and negative clamp were holding the battery positive and negative electrodes, press the test button to observe the test instrument instructions.
- Q: What are the hazards of battery over discharge?
- The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
- Q: What is the meaning of the battery above 12v65Ah?
- 12V represents the rated voltage. 65Ah indicates that the battery capacity (ie 1 ampere current can be used for 65 hours).
- Q: 80ah how much battery storage capacity?
- The size of the battery storage power refers to the battery capacity. Battery capacity is generally calculated in AH (safety). You 80Ah battery capacity is 80Ah, meaning that if you discharge current to 80A, you can put an hour.
- Q: The role of the battery?
- It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.
- Q: How does the battery increase the voltage?
- Chemical energy can be converted into electrical energy device called chemical battery, generally referred to as the battery. After discharge, the internal active material can be regenerated by charging - the electrical energy stored as chemical energy; chemical energy can be converted to electrical energy again when the discharge is required. This type of battery is called a battery (Storage Battery), also known as secondary battery.
- Q: Battery 200ah / 104 what does that mean?
- 2V battery capacity (from 200AH-3000AH have) long design, good stability, the price is also expensive; 12V battery capacity is generally the largest 250AH, design life as 2V, price economy, high current discharge better.
- Q: How does battery activation work?
- If you are talking about dry batteries, that is, to add sulfuric acid can use the battery (commonly known as water bottles), then it is because the long-term storage so that a high degree of oxidation of the negative board, plus acid will be a high temperature, Low, you can add acid in the pool after the addition of a small current for a long time to charge, you can solve. Generally with 0.05C charge to 3 times can be.
- Q: Lead-acid battery how to maintain?
- Open the rubber cap, exposing the exhaust raft, you can see the battery inside, some of the battery exhaust cutting can be unscrewed.
Send your message to us
Solar Battery REX Series for Solar and Wind Power REX-800
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 unit
- Supply Capability:
- 5000000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords