• Sluice gate valve/ Válvula de compuerta System 1
  • Sluice gate valve/ Válvula de compuerta System 2
Sluice gate valve/ Válvula de compuerta

Sluice gate valve/ Válvula de compuerta

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 set
Supply Capability:
100 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Packaging & Delivery

Packaging Detail:Iron fence case or plywood cases
Delivery Detail:It depends on the order quantity

Specifications

Stainless steel penstock, Light weight, corrosion proof, good sealing performance

Stainless steel penstock

 

Gate frame and gate disc with SS304 or SS316

Specification: The specification of square gate valve 200*200-3000*3000 rectangular can be manufactured acc. to the dimensions supplied by customer.

Water depth: 5 meters in normal, specify in ordering when special requirements needed.

Suitable temperature: -20 degree ~ 85 degree

Suitable medium: Sewage, clean water, sea water, etc.

The maximum leakage volume: 1.5L/M/H(M is length of sealing surface, hour is time)

The maxium manual open and close power: up to 350N(not including 350N)

Operation mode: Manual,electric operated,pneumatic operated

Design and manufacture standard: AISC,AWSD1.1-88,SL74-95,DL/T5018-94

 

Gate is one of the most common open/close, use of ram (namely the open-close part, in the gate opening and closing a called ram or gate, gate called ram block) to connect (full open) or truncation (seated) line in the medium.It does not allow for river closure, use should be avoided in the open gate trace, because of the erosion of high-speed flow of medium will accelerate the damage of the sealing surface.Double DE gate at the channel center line perpendicular to the gate of the one-sided as lifting movement, like gate cutting medium pipeline, so as the gate valve.

Q:Generally, how big is the diameter of the installation flange plate gate valve?
Under normal circumstances:Flanged gate valves for piping over DN50,DN50 (below) can be made of wire or gate valves, or flanged gate valves (flanged valves or welded gate valves)
Q:What are the main types of gate valves?
According to the thread position of the valve stem, can be divided into two kinds of open rod gate valve and dark rod gate valve.
Q:Z41T one 10 gate valve and Z44T one, 10 gate valve difference
Z41T one, 10 is single gate, Z44T one, 10 is double gateAccording to the provisions of the JB/T 308-2004 valve type programming method:Z== gate valve4== connection: flange type1== structure: Rigid single gate4== structure: Rigid double gateT== sealing surface material: copper alloy10== pressure rating: 1.0MPa
Q:What does Z941H-25DN250 mean by electric gate valve (excluding electric equipment)?
Cast steel flanged gate valve 25 pressure bore 250
Q:What are the meaning of the cast rigid gate valves z41h-16c?
According to the provisions of the JB/T 308-2004 valve type programming method:Z== gate valve4== flange connection1== rigid single gateH== sealing surface material: Cr13 stainless steel16== pressure rating: 1.6MPaC== body material: carbon steel
Q:What does "Z45W-10T" mean?What does each letter stand for?
T is the material code for the valve body, which stands for copper and copper alloysZ45W-10T, which means manual, flange connections, dark wedge rigid single gate plate, the valve seat sealing surface material directly processed by the valve body, nominal pressure PN10, valve body material for Brass Gate Valve
Q:What is the difference between the cut-off valve and gate valve, the general will use the cut-off valve instead of gate valve
Yes. Globe valves and gate valves are indeed common in certain piping and operating conditions.
Q:The legend of gate valve and stop valve
When the valve is installed, the medium can enter from the bottom of the valve core and enter the two way from the top. Medium from the spool into the advantages of the valve closed when the packing is not under pressure, can extend the service life of the packing, and can be pressure in front of the valve in the case of replacement of packing work. Medium from the spool into the bottom of the shortcomings of the valve driving torque is larger, about 1.05~1.08 times above the entrance, the stem by the axial force of large, easy to bend the stem. To this end, the media from below to enter the way, generally only applicable to small caliber manual stop valve, to the valve closed, the media acting on the spool of force is not greater than 350kg limit. Electric cut-off valve is generally used to enter the media from the top way. The disadvantage of the medium entering from the top is just the opposite of the way it is entered below.Compared with the gate valve, the utility model has the advantages of simple structure, good sealing performance, and convenient manufacture and maintenance. The disadvantage is that the liquid resistance is large, and the opening and closing force is large. Gate and globe valves are fully open closed type valve, cut off or connected as the medium use, not as a control valve.The range of application of stop valves and gate valves is determined by their characteristics. In the smaller passages, the cut-off valve is used when required for better shutoff; in the steam pipe and the large diameter water supply pipe, the gate valve is generally used because of less fluid resistance.
Q:What is the difference between Z41X gate valve and Z45X gate valve?
2 kinds of valve function, there is no difference.Nothing more than a one with a bright bar. One is a dark pole.Dark pole is cheaper.Everything else is the same. Contact me if you need another valve. Zhejiang Futai Valve Co., ltd.. The contact picture is in the head.
Q:What's the difference between the knife gate valve and the stop valve?
Generally large and nominal caliber DN50 mostly with gate valve, especially industrial high temperature, high pressure, highly toxic and so on.Stop valve is able to stop and adjust flow, small footprint, small size, generally less than the nominal diameter, DN50 occasions use it. Two can be closed, in the flow of linear requirements are not high, you can adjust the flow. Just because of its structural characteristics of the valve to make its flow resistance, so there is a demand for throttling with a little more than the gate valve. In addition, the cut-off valve, whether it is a formal or reverse installed, in the opening and closing process, there is always a very difficult, and therefore can not do a great deal, or it is not easy to open and close. In addition, the cut-off valve has a one-way sealing effect of good features, so in the prevention of reverse flow of the working fluid, it also has a place to play.Hope to be of some help to you!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords