• single-side semi-conductive water blocking tape for cable System 1
single-side semi-conductive water blocking tape for cable

single-side semi-conductive water blocking tape for cable

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

water blocking tape
1.armouring/between cable componets
2.easy to be wrapped

Descripition: single-side semi-conductive water blocking tape for cable

Composition: Polyester non-woven fabirc

                     Polyacrylate swelling powder

                     Corrossion inhibitor

Application:  Replacement of flooding compound

                   Under radial barriers

                   Waterblocking armouring/Between cable components

                   Replacement of flooding compound in loose tube construcions

                   In slotted core design/waterblocking reinforcement layers

Be used under neutral screen wires and tapes between cable components.

  Property

Unit

SCWS-25

SCWS-30

SCWS-40

SCWS-50

SCWS-60

Test Method

 Thickness

mm

0.25±0.03

0.30±0.03

0.40±0.04

0.50±0.05

0.60±0.05

ISO9073-2

 Mass per unit area

g/m2

75±8

100±10

120±12

150±15

180±18

ISO9073-1

 Tensile strength

N/cm

≥38

≥45

≥48

≥52

≥60

ISO9073-3

  Elongation

%

≥12

≥12

≥12

≥12

≥12

ISO9073-3

 Surface resistance

Ohm/

≤1500

≤1500

≤1500

≤1500

≤1500

DIN53482

 Volume resistance

Ohm.cm

≤100000

≤100000

≤100000

≤100000

≤100000

DIN54345

 Swelling speed

mm/1'00

≥6

≥8

≥8

≥8

≥8

HYtest-10

 Swelling height

mm/3'00

≥10

≥12

≥12

≥12

≥12

HYtest-11

 Short term stability

°C

230

230

230

230

230

HYtest-5

 Long term stability

°C

90

90

90

90

90

IEC216

 Moisture content

%

<9

<9

<9

<9

<9

ISO287

Remark:

*Widths, ID and OD are available on request.

* More detailed info, pls feel free to contact us.


Q: Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
Bookstore tool book should have "communication project budget", I do is what you say, the budget is divided into estimates and budget, is two steps. So that is not very clear. But what is needed is the preliminary design of the project. The budget is needed for design and drawings. Internal management of this piece, the main thing is that you need to do what the project department, and are generally very complicated
Q: I would like to ask my new workshop power consumption of about 500KW, injection molding machine, 60KW . 40KW . 20KW . the other 20KW, how much should the wire? Respectively how to use lines and switches more
There must be no room for consultation I did not have to do for seven years lazy they want to do nothing irresponsible
Q: What brand of cable is good, what are the top ten brands of wires?
Power circuit box, the home of the circuit is divided into lighting, walls, air conditioning, etc., there is the bathroom and the kitchen line and the separation of the room.
Q: Apple phone display cable or accessories not certified how to do
The control cable transfers the electrical energy from the power distribution point to the power supply lines of the various electrical equipment The rated voltage of the power cable is generally 06 / 1kV and above, the control cable is mainly 450 / 750V The same specifications of the power cable and control cable in the production, the power cable insulation and sheath thickness than the control cable thick
Q: Ipad not charge how the matter. Said the cable or accessories have not been certified, and may not be able to cooperate with this ipad reliable work....
Several sets of cables in the same height of the laying, the adjacent cable between the bridge should be considered maintenance, maintenance needs, generally not less than 0.6m. This is just a matter of theory, it does not matter. Anyway, the actual construction is to do so,
Q: IPadmini. The latest version 7.1.1 up in the morning to see the non-stop display this cable is not certified does not support this feature. The The Charger original. Not on the computer charge. The Ask God to answer more
Data line problem, it may be the data line to the bad, caused by poor contact. For the sake of the root
Q: Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...........................
I think it is possible, because in our (old) substation, the cable trench is the drain, the cable erected in the cable bracket.
Q: How to determine how much wire and cable should be used, the current load and how the corresponding wire, such as 4BV, under what circumstances, YJV240 what circumstances, the load is much more
After the opening is not, if not open like a downstairs to delete the C disk file on the line, if the boot is necessary to set up, sit down little hands and feet.
Q: IPhone6 This cable or accessories have not been certified how to solve
Labor costs you can and workers to discuss, and some labor costs are calculated in accordance with square meters, and some are calculated in accordance with the day, the specific or ask the local construction team
Q: What are the T and T, s of the wire and cable test type?
You should be said: 2-way cross-linked polyethylene insulated PVC sheathed cable 4 core 185 square millimeters, SC is steel pipe, diameter . FC is laying method dark cover the floor or floor. Personal opinion, hope to help you!

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords