• Rack Tower UPS HP9115CRT 1-10KVA System 1
Rack Tower UPS HP9115CRT 1-10KVA

Rack Tower UPS HP9115CRT 1-10KVA

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100 Units pc
Supply Capability:
4500 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Key Features:

 

Rack & Tower Design UPS

 

0.8 Output Power factor

 

LCD Display

 

Intelligent slot available

 

pure high frequency online UPS,with voltage adjustment circuit, provide stable power protection in bad operation environment

 

comprehensive electrical isolation protection and bypass protection, self test function

 

Input neutral and live wire detection function and data protection function

 

Main power failure,going to DC staring ,Convenient and reliable; Main power recover,UPS start automatically

 

 

Model

HP9115CRT  1-10KVA

HP9315CTR  10KVA

1KR/1KR-XL

2KR/2KR-XL

3KR/3KR-XL

6KR/6KR-XL

10KR/10KR-XL

10KR/10KR-XL

Capacity

1KVA/800W

2KVA/1600W

3KVA/2400W

6KVA/4800W

10KVA/8000W

10KVA/8000W

Nominal Voltage

220/230/240VAC

380VAC

Frequency

50/60 Hz

Input

VoltageRange

115~295VAC(±3VAC)

176~297VAC(±3VAC)

304~478VAC(±3VAC)

FrequencyRange

50HZ:(46~54HZ);60HZ:(56HZ~64HZ)

Power Factor

>0.98

Output

Voltage precision

220/230/240X (1±2%)VAC

Frequency precision

50/60HZ±0.05Hz

Power Factor

0.8(option)

Harmonic Distortion

Linear Load<3%    Non-Linear Load<6%

Overload capacity

overload(110%~150%)after 30 seconds automatically transfer to bypass, it recover after  normal load

Current Crest Ratio

3:1

Transfer time

0ms(AC→DC)

Battery

DC voltage

36VDC

72VDC                                       96VDC

192VDC &240VDC optional

Recharge time

5 hours to 90%

Charge Current

1A

4A/8A  optional

1A

4A/8A optional

1A

4A/8A optional

2.0A/4.2A(option)

Panel Display

LCD

Display input and output voltage, frequency, battery voltage, battery capacity, and the percentage of load

Communicate

Communicate  interface

RS232, SNMP card(option, USB port(option)

Working Environment

Temperature

0~40°C

Humidity

0~95% non-condensing

Storage Temperature

-25°C~55°C

Elevation

<1500 meter

Noise Level(1meter )

<45dB

<50dB

Physics Characteristic

Weight(KG)

N.W

16.5

9

26

11.5

26

12.5

18.5

18.5

25

32

25

32

G.W.

18.5

11.5

28

14.5

28

15

21.5

21.5

28.2

35

28.2

35

Dimension (WXDXH)

447x450 x130

447x600x130

447x450x130

447x600x130

447x450x130

447 x600x130

447x600x177

 

 

Q: How many power illuminator can 5Kva 36V transformer drive?
Transformer (Transformer) is a device that uses the principle of electromagnetic induction to change AC voltage. The main components are primary coil, secondary coil and iron core (magnetic core). The main functions are voltage conversion, current conversion, impedance transformation, isolation, voltage stabilization (magnetic saturation transformer) and so on. According to use can be divided into: power transformers and special transformers (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, mine, variable audio transformers, intermediate frequency transformers, high frequency transformer, transformer, instrument transformer, the impact of electronic transformer, reactor, transformer etc.). Circuit symbols are often used as the beginning of numbers. Examples: T01, T201, T, etc..
Q: What type of low voltage transformer should be adopted for safety lighting power supply?
In general, indoor transformers are used in general practice
Q: Why should lighting transformers be used in factories and mines?
In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
You must know the quantity and power of the lamp to determine the transformer
Q: Why is elevator lighting transformer installed?
9.4.5 well distribution shall comply with the following requirements:1 the elevator hoistway shall be dedicated to the elevator, and no equipment, cables and other devices related to the lift shall be installed in the hoistway.2 the well shall be provided with illumination, and the illumination shall not be less than 501x, and shall comply with the following requirements:
Q: The transformer zero line has broken, has the result to the household illumination circuit?
The zero line is connected to the transformer neutral point of transformer, three FireWire for its voltage is 220 volts, according to regulations, the total can not take the zero line fuse, switch, because once the zero line is disconnected, the rest of the line will no longer be a neutral line, into the use of electrical appliances connected to two the conductor, according to the characteristics of series circuit, each phase with electrical voltage, on load distribution, change the original load smaller which phase by using electrical appliances, will damage due to excessive voltage.
Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
What you think? Your light is 220V, right. Over 36V, it's better not to live with electricity unless there is good protection
Q: 3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
Pure resistive load, the power factor is 1.3 *100W=300W, is required for the capacity of the transformer.
Q: What's the function of the lighting transformer?
In addition, can be rated power supply voltage of not more than 1000V AC circuit, as a machine tool and mechanical equipment control power, work lighting and signal light power supply, can also be used as a small power supply!
Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Pe=19.5KW, installed capacityKx=1 coefficient of demandPjs=KxPe=19.5KW, calculated loadCOS, phi, =0.85, power factorIjs=KxPe/3/220/cos phi (Ijs calculates current, voltage, 380V/220V, three-phase)=1*19.5*1000/3/220/0.85=34.76A
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications.if you have interesting, please kindly contact us! We will provide our good quality products and best services to you!

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2006
Annual Output Value US$10 Million - US$50 Million
Main Markets 9.09% North America
9.09% South America
9.09% Eastern Europe
9.09% Southeast Asia
9.09% Africa
9.09% Mid East
9.09% Eastern Asia
9.09% Western Europe
9.09% Southern Europe
9.09% South Asia
Company Certifications UPS CE UG/UX 1K; UPS CE (UG/UX) 2/3K; standards organisation of nigeria soncap; Soncap UX6K

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shenzhen China
Export Percentage 61% - 70%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: 10,000-30,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords