Pure Sine Wave No Break 3 Phase UPS 10KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 5000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Phase: single/three phase,3 phase input 1 phase output
Protection: Overvoltage
Weight: 35-93KG
Output Voltage: 220/230/240VAC
Type: On-line
Application: Networking
certificates: CE&ROHS
color: black or white
Input voltage Tolerance: 304-478VAC +/-3%
Input Frequency Range: 46Hz~54Hz
power factor: 0.7
Battery: maintenance-free lead acid battery
indicator: LCD
Output wave form: pure sine wave
Specificatons
1.Single/three phase
2.IGBT power componet
3.Paralleled redundancy
4.Advanced Current Control
5.Motorola Microprocessor
Features
1. Texas Instruments DSP processor
2. Motorola Microprocessor
3. Module design
4. Advanced Current Control
5. IGBT power component
6. Power Factor Correction
7. Online Maintenance
8. High frequency and double conversion on-line technology
9. Advanced PFC technology
10. EPO Function
11. Wide input voltage range
12. Fully digitized microprocessor control
13. Parallel redundancy
14. Advanced battery management
15. Lightning and surge protection, short circuit and overload protection
16. Multilingual LCD display
- Q:Internet cafes charge machine, if equipped with a UPS, generally with what kind of? how much is it? How long will the battery last? Does not affect the customer's billing record, right?
- Configuration ups, generally based on the power of the equipment you use, need to power after the power to decide. You need to know how long you will continue to supply the power after the power outage. Configuration ups the role is to let you continue to work after a period of power for some time, not affected. More well-known brands are: Shenzhen Hills, the United States Hills, APC, Delta, Keshi Da, Emerson and other brands ups power Backup: more conventional power can be powered after 3 to 30 minutes: 160 ~ 1000 yuan (for reference only) Compared to conventional power supply can be powered more than 30 minutes: 1060 yuan or more Online: (external battery) is usually available 1 to 15 hours optional, the price is slightly more expensive. Hope to help you.
- Q:UPS power supply is mainly used in what areas
- Banks, telecommunications, factories and other data is very important place will be used
- Q:What is the difference between EPS and UPS?
- UPS is the abbreviation of UninterruptiblePowerSupply, that is, we often say UPS uninterruptible power supply. Common UPS on the market are mainly on-line (OnLine) and back-off (OffLine) two. EPS emergency power supply system is the abbreviation of Emergency Power Supply, is to meet the special requirements of the fire industry emergency power supply. First, the backup UPS in the normal electricity directly from the mains power supply to the load, when the electricity beyond its scope of work or power outages, through the switch to battery inverter power supply. Its characteristics are: simple structure, small size, low cost, but the input voltage range is narrow, the output voltage stability accuracy is poor, there is switching time, and the output waveform is generally square wave Second, the online interactive UPS in the normal electricity directly from the mains power supply to the load, when the electricity is low or high, through the UPS internal regulator line regulator output, when the electricity is abnormal or power failure, through the conversion Switch to battery inverter power supply. Its characteristics are: a wide input voltage range, low noise, small size and other characteristics, but there are also switching time.
- Q:Petrochemical industry, two UPS dual-machine hot backup power supply for the instrument, this part of the load how to calculate the need to account for the total capacity of the load?
- No, what do you mean when the UPS is powered by the load, and then calculate the total load when you add the UPS capacity to the load? Can not be calculated, UPS is only the transmission part of the electricity, UPS own load should be (1 - output power) * UPS capacity
- Q:Ups power can air conditioning, a 1.5p air conditioner requires much power Ups power?
- From a professional point of view, it is recommended that UPS does not have air conditioning. The reason for the air conditioning for the inductive load, the starting current is very large, so the requirements of the UPS is very high, and the damage to the UPS is quite large. If you really want to use UPS with air conditioning, then recommend UPS choose 3KVA more insurance.
- Q:What is UPS? What's the role?
- It should be UPs it, USP seems to be a pistol model, UPs role is like a regulator, will enter the computer's current will not have much fluctuations, so as to ensure the safety of the hardware, and power outage will provide a section Of the time of the power supply, to ensure that you can safely save the information after the shutdown, to prevent damage due to power failure
- Q:A group of small servers, about 4-7 nodes, the wave of TS10000 series. I think about 10kw ups enough, do not know what the choice of the brand, the battery can be used for half an hour enough, please help solve, thank you
- 10kw ups battery can be maintained for half an hour, the battery should be great, I recently considered to friends with a battery in series directly to a group of server power supply. May be better!
- Q:12-volt car inverter in the use of how old break?
- How the inverter works: ? 1. DC can be converted into alternating current through the oscillation circuit ????2. The resulting alternating current is then boosted by the coil. At this time, the alternating current of the square wave is obtained ????3. Rectify the resulting alternating current to get a sine wave ??????AC-DC is relatively simple, we know that the diode has a one-way conductivity, you can use this characteristic of the diode connected into a bridge, so that one end is always inflow, the other end is always out of this to get the voltage sinusoidal change Of the DC. If you need smooth DC also need to rectify, the simple way is to connect a capacitor. ??????Inverter is a DC to AC transformer, in fact, it is a voltage inverter with the process. Adapter is the utility power grid AC voltage into a stable 12V DC output, and Inverter is the Adapter output 12V DC voltage into high-frequency high-voltage alternating current, the two parts are also used with the current more Pulse width modulation, ??PWM technology. Its core part is a PWM integrated controller, Adapter with the UC3842, nverter is used TL5001 chip. TL5001 operating voltage range of 3.6 40V , which has an internal error amplifier, a regulator, oscillator, a dead zone control of the PWM generator, low voltage protection circuit and short circuit protection circuit. ??????Inverter, can be classified from the output waveform, power, engineering structure. ?????From the waveform on the points: one is a square wave inverter, the other is a sine wave inverter. ?????From the power up to divide, can be high power and low power two categories. Less than 5000W can be called low-power, more than 5000W called high-power inverter.
- Q:Ups power supply needs 380V output how much V DC battery?
- Through the installation of SNMP card, UPS can also achieve network monitoring function, through the network can be a long time to observe the UPS operating parameters and to manage. (1). The inverter uses SPWM high-frequency sine wave pulse width modulation technology (2). The inverter uses IGBT module design, extremely high reliability (3) The inverter uses the IGBT module design, (4). Data processing and panel display are controlled by a separate CPU (5). Intelligent network communication management function (6). Wide input voltage range (7). Pure sine (8). Compatible with the generator system (9). No need to start the electricity (DC start) (10). Multi-function dual-language LCD display panel (11). Can double (13). Perfect UPS fault recording function (14). Overload, short circuit automatic protection function (15). Can be the main function of the power supply, the unique bypass tracking system (12). Advanced delay off button design, to avoid misuse (13). Self-detection and testing of battery status
- Q:How the UPS power supply sounded
- Look at the contactor is not inside the contact is not good
1. Manufacturer Overview |
|
---|---|
Location | Guangdong,China (Mainland) |
Year Established | 2004 |
Annual Output Value | US$10 Million - US$50 Million |
Main Markets | Oceania 1.00% Mid East 10.00% Eastern Asia 5.00% Western Europe 10.00% Northern Europe 1.00% Southern Europe 1.00% South Asia 5.00% North America 1.00% South America 1.00% Eastern Europe 20.00% Southeast Asia 30.00% Africa 15.00% |
Company Certifications | copyright Certificate; RoHS certificate; LVD certificate; EMC certificate |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Shekou Port,Yantian Port,Huangang Port |
Export Percentage | 91% - 100% |
No.of Employees in Trade Department | 11-20 People |
Language Spoken: | English, Chinese, Russian, Italian |
b)Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | 6 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | High and/or Average |
Send your message to us
Pure Sine Wave No Break 3 Phase UPS 10KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 5000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches