• PL Series Energy Saving Lamp System 1
PL Series Energy Saving Lamp

PL Series Energy Saving Lamp

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1000 Pieces pc
Supply Capability:
5000 Pieces per Day pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
Detailed Product Description

1)power factor:more than0.75 2)65lm/W 3) Certification: CE/EMC/ROHS 4)lower light attenuation 5)High lumens efficiency

Product name: PL series energy-saving lamp

Code:YSL-PL-17-36W

Wattage:36W

Base: 2G11

Voltage: 220-240V

Tube Dia.: 17mm

Lumens:1620

Color Temp.: 2700/6700K

Life Time: 3000h/6000h/8000h

Qty/Ctn: 100pcs

Meas.:44cm*23cm*25cm

Q: In a 15.2m wide, 14.4m deep into the ground to build a house around the rear is to repair the house, how to design the Sishiliangting kitchen? To get very good lighting, please attach the design. Thank you
That is nothing more than increasing the window area on one wall, and making big windows on the three sides. The mirror can be paved with a 45 degree angle, reflecting large amounts of sunlight at noon. If you have that condition, you can also install the function to adjust the mirror surface and reflect sunlight into the sun at any time.
Q: New commercial housing, lighting spacing is inadequate, how to protect people?
Answer the landlord's questionsInterim Provisions on living, living and building spacingThe fourth chapter is "the present situation of residents housing sunshine occlusion treatment" in the provisions of article thirteenth: where the competent department of City Planning Administration approved the construction of the new building block housing sunshine status of residents, the construction units (including individual housing) should take the initiative in accordance with the following provisions: for shielding sunlight situation of residential housing, living room window to the center point (are outside the wall, meter) during the winter solstice sunshine time in less than 1 hours, each according to their room is blocked in giving a one-time compensation for 800 yuan to 2000 yuan. Illegal construction and new building height two times the level of the residents outside the housing will not be compensated.Therefore, in accordance with the existing laws and regulations as long as the developers are building space and the residents where the floor to the legal minimum limit - 18 meters, at the same time, residents of the housing during the winter solstice sunshine time more than 1 hours, in accordance with the existing provisions of the construction of new buildings, even affected the residents of the right lighting, because of its architectural space according to the provisions on the standards do not have to bear the obligation of compensation.The property law has expressly stipulated the right of lighting"Property law" stipulates (eighty-ninth): the construction of buildings, not in violation of state standards relating to construction, to prevent adjacent buildings ventilation, lighting and sunshine.So if you buy a commercial house, it violates your right of lightingThen you can check out the developer defaultsOr ask developers to pay for itIf you negotiate, you can't reach an agreementYou are advised to bring a suit in the local people's court
Q: Seek advice: how to design the darkroom ventilation lighting?
Don't look bad in the mirrorWhat kind of transparent light?Enchanted glassMake a wall and blow up the wall
Q: What are the advantages and disadvantages of the ordinary side window and skylight in the building?
The utility model has the advantages of simple structure, convenient arrangement, low cost, clear direction of light, favorable for forming shadows, suitable for watching objects with strong stereoscopic feeling, and viewing outdoor landscape. Disadvantages: uneven illumination distribution, high illumination near the window, rapid decrease in horizontal illumination outside the window When the lighting area is equal and the window elevation is the same, the square window lighting amount (the sum of illuminance of indoor points) is the biggest, the vertical rectangle is second, and the horizontal rectangle is the smallest. But from the uniformity of illumination, the vertical rectangle has the best uniformity along the deep direction, and the horizontal rectangle is more uniform along the width directionThe main factor affecting the uniformity of indoor daylighting is the window wall. The wider the window wall is, the worse the lateral uniformity is.The biggest advantage of skylights is that they are conducive to the collection of light and the uniformity of illuminance.Skylight form:(1)Rectangular skylight: This skylight has a higher position and is less prone to glare. To avoid direct sunlight, shoot people into the roomInside, the skylight glass is best south to north.(2)Horizontal skylight (horizontal, rectangular skylight): the window of this skylight should also be facing north and south.(3)Zigzag skylight: this roof has sloping ceilings to make reflective surfaces, increasing reflected light, lighting efficiency higher than rectangular skylights, and windows generally facing north.(4)Flat skylight: characterized by high lighting efficiency, but easy to pollution. However, measures should be taken to prevent light pollution, prevent direct sunlight and prevent condensation. The minimum area required for a flat roof. Rectangular maximum(5)Well skylight: this type of window is mainly for ventilation and lighting.
Q: In order to have good lighting, the southern hemisphere has the best orientation
In order to have good lighting, the southern hemisphere is best for the south facing north.
Q: Mine is multi tier, 36 meters from the front
The 7 floor, and the 9-11 layer is the dust suspension in the atmosphere, the most dirty air.7 on 8, have heard of it, 8 Feng Shui is not good.Just choose one of the 5,6,7 layers.There is a garage, it is the 5 floor, according to the sun height angle, the sun almost noon
Q: Consult the polycarbonate, which is commonly known as the PC board, and what is the main difference between the FRP and the lighting board, thanks to its material characteristics and scope. Thank you!
PC sunlight plate and FRP daylighting tile difference, material composition explanation 1, PC sunlight plate is by polycarbonate surface coextrusion 50um layer anti ultraviolet UV layer, hollow structure extrusion high performance lighting material. 2, FRP lighting board is a glass fiber reinforced polyester (FRP lighting board), commonly known as glass fiber reinforced plastic, also known as transparent tile, which is mainly composed of film, unsaturated resin and glass fiber. Two, material difference 1, polycarbonate is the most excellent engineering plastics, it has light, refractory, high impact strength, high transmittance, high stability, finished products easy to bend and other characteristics. And it is a kind of energy saving and environmental protection material. It is the preferred material for making daylighting materials. 2, FRP's main material is unsaturated resin, its high strength and flammable, resin itself at 50 degrees Celsius, easy to decompose, stability is poor. Resins are chemically synthesized, using styrene solvents and are toxic. Three, performance difference 1, light transmittance: PC sunlight board and FRP lighting tile transmittance is about 85%, but PC sunlight board has high permeability, no fog, that is called "misty" feeling. FRP daylighting tile is a composite material, glass fiber block the view, plus resin itself permeability is not enough, daylighting tile overall permeability is not good, fog is big, the line of sight feels misty. 2, insulation: heat transfer coefficient PC is 0.2W/m.k, the heat transfer coefficient of FRP is 0.4w/m.k, PC insulation was better than FRP times, PC sun board with hollow structure, so the overall insulation of PC sun board is much better than that of FRP lighting tile. From another angle, daylighting material adopts PC sunlight board, which is more energy saving than FRP lighting tile.
Q: Please face the south side of the house is East, lighting is good, but also west, lighting is good
A house with a west facing south is better than a south facing east. The lighting time of a house facing south east, mainly in the morning. The daylight time of the room facing south is in the afternoon. Although the room facing south and West in summer is very hot because of the sunshine. However, in winter, living in the west facing the room, you can enjoy the warm sunshine in winter afternoon. The room facing south and East is bathed in sunshine only in the morning, although it looks south, but it is not warm enough.Of course, due south direction of the house is definitely the best, because the lighting for the longest time. However, this type of house is relatively small, and the price is more expensive.
Q: Indoor lighting is not good, how to make up?
General lighting is not good houses are on the house lights to improve the light on the wall a bit: to choose white latex paint, make indoor wall white reflective tiles good selection effect the white Yang Fan out of the village is relatively better, but this can only increase 4 light mainly on the way to strengthen the light decoration.
Q: Look at the house, good or bad depends on the winter solstice, summer solstice, two days of lighting, there is no understanding, explained
Because the summer solstice is the longest day of the year, and the winter solstice is the shortest day of the year, so look at the two days of sunshine time, you can know the lighting of the house is good.In fact, you don't have to stay in your room all day, but you can record the morning and evening sun hours in your room during the two days. Summer solstice sunshine time is less than 6 hours, the winter solstice sunshine time is less than 4 hours, the room lighting is insufficient.
Our company uses scientific, rigorous and advanced technology, with the industry's advanced management concepts and perfect after-sales service. We carefully promote the well-known production energy-saving lamps. Let us work with you to create a brilliant lighting future in twenty-first Century, promoting the "green lighting of China".

1. Manufacturer Overview

Location Jiangsu,China
Year Established 2004
Annual Output Value Above US$100 Million
Main Markets 20.00% Domestic Market
20.00% Africa
10.00% Southern Europe
10.00% Northern Europe
10.00% Western Europe
10.00% Mid East
10.00% Eastern Europe
10.00% South America
Company Certifications RoHS;ISO14001 2004; ISO 9001:2008;CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Lianyungang
Export Percentage 21% - 30%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: 50,000-100,000 square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range High and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords