• Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection System 1
  • Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection System 2
  • Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection System 3
  • Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection System 4
  • Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection System 5
Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection

Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection

Ref Price:
get latest price
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
100 pc
Supply Capability:
5000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

DZ47-63C 1P 1A 

Product Description:

Product Details

Brand Name

Shaman

Item No.

DZ47-63C 1P 1A

Color

White

MOQ

100 pcs

Packing

240 pcs into one carton.

Important Information

Send sample

Yes

Delivery time

Within 30 days.

Payment terms


T/T 30% deposit, the balance before the shipment.

     


Introduction:

 

1.DZ4763 high breaking capacity circuit breaker is used for AC 50Hz(60Hz),single pole 240V,2,3,4 poles 415V,

for protecting the circuit that overload and short circuit may take place.

2.Circuit breaker can be used in lighting and electric motor distribution system in industrial enterprise,

commercial district,high-rise building and dwelling house.

3.It conforms with the standard of IEC60898. 


Specification:

  • Rated temperature +40

  • Rated voltage 240V/415V AC

  • Rated current(C):1,3,5,6,10,15,16,20,25,32,40,50,60,63A

                               (D):1,3,5,6,10,15,16,20,25,32,40A

  • Electric endurance not lower than 6000 times

  • Mechanical endurance lower than 20000 times

  • Tropical test:2 kinds

DZ47(C45N)
StandardRated   currentPoleVoltageBreaking
(A)(V)capacity
  (A)
BS3871-11 to 4012404000
IEC8982,3,44154000
IEC157-11 to 401220/2406000
2,3,4220/24012000
2,3,4380/4156000
DZ47(C45N)
StandardRated   currentPoleVoltage(V)Breaking   capacity(A)
(A)
BS3871-11   to 4012406000
IEC89850   to 602,3,44156000
 50 to   6012404000
 2,3,44154000
IEC89811220/24010000
2,3,4220/24020000
2,3,4380/41510000
31220/2408000
2,3,4220/24020000
2,3,4380/4158000
10 to 401220/2407000
2,3,4220/2401600
2,3,4380/4108000
501220/2406000
2,3,4220/24010000
2,3,4380/4106000
501220/2405000
2,3,4220/24010000
2,3,4380/4105000


Characteristic curve:

Dimension:

Detailed Images:

Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection

Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection

Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection

Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection

Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection


Construction and Feature of Miniature Circuit Breaker/MCB:

  • Protection against both overload and short circuit

  • High short-circuit capacity

  • Easy mounting onto 35mm DIN rail

Characteristics:

  • The short-circuit release is to be set up to 3 In through 5 In.It serves especially for protection of circuits with such devices which do not cause any current surges(lights or socket circuits etc.)

  • The short-circuit release is to be set up to 5 In through 10 In.It serves especially for protection of circuits with such devices which cause some current surges(groups of bulbs, motors etc.)

  • The short-circuit release is to be set up to 10 In through 20 In. It serves especially for protection of circuits with devices which cause high current surges(transformers,double-pole motors,motors with heavy start etc.)

  • Nominal voltage:1P (single-pole)~230/400V 50/60Hz
    3P (three-pole)~400V 50/60Hz

  • Protection:IP40 for a sole MCB with its design, it protects against a hazardous finger or instrument touch as well as against very small foreign objects; It is without any protection against water leakage (water protection is to be solved with design of the switchboard casing)

    Packaging & Shipping:

    Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection

    Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection

    The wearhouse:

    Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection

    The certificate:

    Mcb Dz47 C45 1p1a Mini Circuit Breakers Miniature Circuit Breaker Protection

    The exhibition:

    Why Chose us:

    • We have our own engineer teams,will supply the professioanl design for you.

    • Every new product can be made accurate by your design and demand.

    • Enough stock to fit your urgently need.

    • Keep smooth delivery on time.

    • Perfect package according to your demand.

    Our service:

    • 7day*24hours Hot-line & Email Service.

    • Your inquiry related to our products or prices will be replied in 24hours.

    • Well-trained and experienced staffs to answer all your questions in fluent English.

    • OEM&ODM is available.




    Q: How is the circuit breaker different from the air circuit breaker?
    Transformer, line capacitance current and other small load), knife fuse switch is a switch and fuse combination of electrical appliances,
    Q: What is the difference between a circuit breaker and other switches?
    replace the contacts and components more convenient, and more used in the power side of the main switch
    Q: Discussion on the Selection of Circuit Breaker in Low Voltage Circuit
    and the frame circuit breaker rated current is much larger, generally 630A-6300A (such as our company's DW15, DW16 and DW17 series
    Q: Which is the circuit switch, that is the circuit breaker
    sub-capacity and so are greater than Molded Case circuit breaker. This is a fundamental difference,
    Q: Short trip also tripped, overload also trip it?
    The first no overload and short circuit protection only leakage protector, also known as RCD leakage switch
    Q: Home circuit breakers and how much air is open
    the principle of air switch, the function of the general situation for the customer matching distribution box in the process, should be in a small lighting, socket, air conditioning large matching principle
    Q: What is the common circuit switch called switch
    Over-current release with electromagnetic, electronic and intelligent release, and several several
    Q: Selection of Circuit Breakers in Low Voltage Circuits
    Compared with the fuse, the thermal protector has a significant advantage
    Q: What is the choice of low voltage electrical circuit breaker?
    This feature is often useful when the circuit breaker and the system are exposed to the same heat source. In this case, the protection circuit can track the equipment at higher temperatures for enhanced wiring protection requirements
    Q: he circuit breaker in the circuit mainly plays a protective element what protects the two functions of the element
    the thermal element drives the tripping mechanism for a certain period of time.