LED T8 Tube 10W 600mm glass tube AC drive
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 pc
- Supply Capability:
- 100000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
Products features
1. Aaward-winning technology of 2014 Geneva International Exhibition of Inventions
2. Patented AC (Alternative current) directly drive.
3. No LED driver design, replace the LED driver by AC chips, more stable and reliable.
4. Prolong the service life of T8 tube to 50,000 hours, it is 2 times as long as traditional driver.
5. High light efficiency. Use high quality SMD chips to ensure the high light efficiency
6. Low lumens depreciation. Less than 3% per year. The users needn’t to replace the tube during 4-8 years.
Perfect AC directly drive solution which won the won the 2014 Geneva International Exhibition of Inventions.
As the global leader in LED driving technology.
AC Chips replace the traditional LED driver.
The service life of AC chips more than 100,000 hours,so service life of the whole tube more than 50,000 hours.
The ueser needn't replace the tube in 4-8 years.
LED T8 tube 10W | |
Electric parameter | |
Power | 10W |
Voltage | 160~270V AC,50/60Hz |
Power Factor | ≥0.95 |
Operating Temperature | -40℃~50℃,20%~90% H.R. |
Storage Temperature | -40℃~80℃,10%~90% H.R. |
Optical parameter | |
Color Temperature | 5500-6300K |
The LED type | 5730 SMD LED |
Number of LED | 75 PCS |
Angle of LED | 120(Degree) |
Luminous Flux | 850Lm |
Photosynthetic efficiency | ≥85Lm/W |
Physical parameter | |
Level of Waterproof | IP55 |
Service life | 50000 H |
Electrical categories | ΙClass |
Lamp cover material | High light transmittance glass tube |
Lamp cover color | Milk white |
Length | 1200mm |
diameter | 26mm |
Lamp weight | 0.41Kg/0.904lbs |
Mode of package | 30Units/Ctn |
Package measurements | 640*220*185MM |
Package weight | 8KG (17.7lbs) |
Revolutionary no driver LED, Alternative directly drive, high efficiency and stability
Pioneered the AC directly drive LED solution, replaced the traditional LED driver by TF-11 and G13 chips. The patented technology won the award of 2014 Geneva International Exhibition of Inventions. The reliability and service life of LED are improved enormously by AC directly drive solution. The service life of AC drive solution surpasses 100,000 hours.
High grade luminous source
Professional encapsulated SMD 5730 with high quality LED chips ensures the LED resource obtaining excellent protection of optical attenuation and the heat conduction ratio. Reduced the optical attention rate to the minimum value as 3% per year.
Triple heat dissipation, Super long service life.
Utilizing high thermal conductivity aluminum plate, high purity glass tube and no LED driver consumption, the triple heat dissipation design ensures that chips can conducting the heat rapidly. Our LED tubes are driven directly by Alternative current without delay start, unaffected by electric fluctuation. The service life of T8 tube is more than 50,000 hours and it’s 2 times than that of traditional LED driver tube. So users needn’t replace the tube in 4-8 years.
Uniform illuminance, Comfortable visual sense
The LED tubes use high luminous transmittance glass tube to reach high transmissivity, the transmissivity over 99%.
The surface of tube was frosted without light spot. The light is soft and pure spectrum, high CRI ( color rendering index )without ultraviolet ray, infrared radiation, ensure users a comfortable visual sense.
Our tube process soft light, pure spectrum, high CRI ( color rendering index ) without ultraviolet ray, infrared radiation to ensure users a comfortable visual sense.
- Q: How to meet? The rectifier is very easy to connect
- Went on two of the ballast with black and white and two sets of lines, a set of a tube, the last wire connects ballast is ok, if the change over time, to check whether a set of ballast to replace, so consider in ballast, if only a single change, that is about to change the bulb.
- Q: The lighting is replaced by LED lights and circuit problems
- LED bulbs have special or built-in support, which is completely different from the old fluorescent lighting fixture. The suggestion is that the old stents can be recycled.
- Q: Does a fluorescent lamp change an led light to change a light tube only?
- No, lED tubes do not use a ballast starter.You need to remodel the original fluorescent lamp holder.
- Q: Where is the very thin daylight lamp usually bought?
- There's no need for a lamp slot for the hardware store. Because it's on the lights. Most of them are screwed. The light bulb of a home. You don't need to buy a switch. General 26 w.. 20 yuan
- Q: The same thing is 5w, is this LED tube power or is this a fluorescent lamp?
- Power consumption is the same, but brightness is different.The fluorescent lamp is good for people's eyes, LED saves electricity, oneself choose.
- Q: What does philips mean by TLD36w / 54-765
- Yeah, I did it for you, I think it's the bottom, Let's see if it is ~ TLD ~ T8 Dailyght 160-240v (model) 36 ~ 36 w.I hope my answer will work for you.
- Q: How to remove fluorescent lamp tube
- What material is LED fluorescent lamp fittings, such as shell, block?
- Q: What's the difference between an LED fluorescent lamp and an ordinary light tube?
- The next part of LED color temperature: the work of various lighting fixtures... | returns the advantage of the log list LED fluorescent lamp to share the copy address log address: use Ctrl + C to copy and post it to the friend. Broadcast to weibo pig eight quit to do the monk May 17, 2011, when reading and classification (0), (4) comments: personal diary permissions: public font: set-top permissions set in small cuhk more ▼ ▼ in recommended log To illicit close log Remove the edit the led fluorescent lamp to become one of the earliest to enter indoor led lamps and lanterns, because it is relative to fluorescent lamp has 10 major advantages: 1. High luminous efficiency Fluorescent lamp luminous efficiency is about 55-80 lm/W (Philips company T8 fluorescent lamp luminous efficiency is 72 lm/W), and LED the luminous efficiency of above 100 lm/W, recently Cree company XLampXP - G luminous efficiency has been to 130 lumens/W, and will improve in the future. The difference is now nearly double. And it could be more than three times that. The efficiency of lamps and lanterns efficiency is mainly to point to effective light effect, because fluorescent lamp is 360-degree, and the light that is sent in the opposite direction has no use. So fluorescent lamp USES a white chimney normally, can take a considerable part of the reverse light reflected, in general, fluorescent lamps and lanterns of efficiency is about 70%. LED fluorescent lights are 120 degrees, so all light is efficient.
- Q: How does the T8LED light tube replace the fluorescent lamp tube
- Tube at both ends a firewire, on the other side is zero, the two feet per head are connected together, by one or two can be, if with neon bulb starter, starter can be twisted off, then remove ballast two joint together can change LED bulb.
- Q: Can the T5 light tube be free of ballast?
- The T5 bulb must be ballast, and electronic ballast, no ballast to light the T5 lamp.
Send your message to us
LED T8 Tube 10W 600mm glass tube AC drive
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 pc
- Supply Capability:
- 100000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords