LED Lighting Tube Tube5 Led Tube Light T
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 set
- Supply Capability:
- 100000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
LED Lighting Tube Tube5 Led Tube Light T Specification:
Material | Aluminium + PC cover |
Body size | 600mm |
Light quantity | SMD2835/96Pcs |
Power Installation | Power external in the tube |
Work voltage | AC100-240V |
Power consumption | 10w |
Power factor | >0.92 |
Work temperature | -20°C~+50°C |
beam angle | 120° |
Color rendering | >80ra |
Color temperature | 2700-7200k |
Luminous flux | 950Lm |
Light-to-Electric conversion yield | 95% |
Life span | 50000hrs |
Main Feature of LED Lighting Tube Tube5 Led Tube Light T:
1.Magnetic&electronic ballast compatible
2.No need to remove starter or ballast.
3.No professional electrician needed
4.Easy for installation
5.No labor cost, maintenance free
6. instant start.
7. No UV, NO mecury, healthy for human body
8.Power consumption:24w
9.Certificate:CE,RoHS,FCC,PSE,TUV,UL
10.Low power consumption
11.3 years warranty
10.No fluorescent flickering
11.No RF interference, no buzzing noise.
12.No hazard of mercury or lead entering the environment
13.Easy in stallation
14.No dangerous of glass broken
LED Lighting Tube Tube5 Led Tube Light T Description:
1.Living room, bedroom,kitchen, washroom;
2.School, university, hospital,hotel;
3.Conference,meeting room, show room,showcase;
4.Commercial complexes;
5.Factory,plant,warehouse,office;
6.Supermarket,department store.
Images:
FAQ:
What certificates do you have for your products?
ISO
- Q: Ordinary fluorescent lamp ballast can be replaced with led daylight lamp tube
- The fluorescent lamp tube changes LED lamp tube, need to change the line, remove old ballast and the generator, connect the power directly, because, the LED lamp tube has the power source inside.
- Q: I hope my answer will help you
- There is a minimum of a spring, which can be applied to each side, and if one can be pressed in, it can remove the lamp. I hope my solution will help you
- Q: Why is the household daylight lamp attached to the battery?
- If it's a solar lamp for household use, it's a contravariant.That's the dc fluorescent lamp, and it's not communicating.
- Q: Fluorescent lamp double lamp tube wiring method
- Is ok, if the electronic ballast, take a look at is a of the area, or area of two, if is one of the region, the four lines of the same light foot directly connected to the ballast end (the end of the four terminal) ballast directly connect the power cord is ok, on the other side of the ballast area 2, the light of the light feet a line connected to the ballast, on the other side of the ballast connect the power cord is ok!!
- Q: What installation is the T8 LED tube?
- Electronic ballast installation: Turn off the power switch. 2, remove the electronic ballast from the lamp, and make the following changes to the lamp circuit 3, select the LED lamp, and turn the LED lamp down. Turn on the power switch
- Q: What is the distinction between led fluorescent tubes and ordinary daylight bulbs?
- Secondly, LED fluorescent lamp power is small, so compare save electricity, life is long, but the price is more expensive, and common fluorescent lamp power is great, life is not too long, will leak after crushing toxic substances, but the price is cheaper.
- Q: Feasibility analysis report of LED lamps
- A: hello, may I help you? Is the report for the government? I have contact information in my profile
- Q: Fluorescent fluorescent lamp tube can replace led fluorescent lamp tube?
- When installing, the ballast is removed directly from the left and right side of the fluorescent lamp. No need to replace the lamp holder, which is completely universal.
- Q: How much energy does normal lamp tube compare with LED light tube?
- When installed the LED fluorescent lamp is very simple, the original of the fluorescent lamp to remove the LED fluorescent lamp, ballast and electric fluorescent starter, let 220 v ac mains on both ends of the LED fluorescent lamp directly. LED fluorescent lights are up to 80 percent of the electricity, and more than 10 times that of a normal lamp.
- Q: Which is better? In terms of power and price
- I think this brother is not very clear about leds; In fact, the lamp contains the way of the patch Led lamp bead classification 1. Straight insert small power specifications are as follows: straw hat/helmet, round head, concave, ellipse, tombstone type (2 * 3 * 4) bullet, flat head, type (3/5 / flat bread) piranha, etc. 2. SMD patches are usually divided into (3020/3528/5050, these are positive luminescence) / 1016/1024, and these are the lateral luminescent sources. 3. Large power leds are not classified into the patch series, their power and current usage are different, and the photoelectric parameters are very different. Single single high power LED light source, such as no heat dissipation base (generally for hexagonal aluminum), its appearance and the average patch without too big gap, high power LED light source is circular, encapsulation mode basic and SMD patch is the same, but with SMD patch in the conditions of use/environment/effect has essential difference. Photosynthetic efficiency as to what you say, he is equal to the luminous flux/power is the power points, as we have 3014 (0.1 W), 3528 (0.06 W), 2835 (0.5 W)... The flux is also the customer's requirement, we have 5 to 60 lm here, of course the price is different. Hope is useful to you
Send your message to us
LED Lighting Tube Tube5 Led Tube Light T
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 set
- Supply Capability:
- 100000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords