LED Lighting Tube T5 CE RoHS TUV ETL t5 Bracket Lamp
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 set
- Supply Capability:
- 100000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
LED Lighting Tube T5 CE RoHS TUV ETL t5 Bracket Lamp Specification:
Material | Aluminium + PC cover |
Body size | 600mm |
Light quantity | SMD2835/96Pcs |
Power Installation | Power external in the tube |
Work voltage | AC100-240V |
Power consumption | 10w |
Power factor | >0.92 |
Work temperature | -20°C~+50°C |
beam angle | 120° |
Color rendering | >80ra |
Color temperature | 2700-7200k |
Luminous flux | 950Lm |
Light-to-Electric conversion yield | 95% |
Life span | 50000hrs |
Main Feature of LED Lighting Tube T5 CE RoHS TUV ETL t5 Bracket Lamp:
1.Magnetic&electronic ballast compatible
2.No need to remove starter or ballast.
3.No professional electrician needed
4.Easy for installation
5.No labor cost, maintenance free
6. instant start.
7. No UV, NO mecury, healthy for human body
8.Power consumption:24w
9.Certificate:CE,RoHS,FCC,PSE,TUV,UL
10.Low power consumption
11.3 years warranty
10.No fluorescent flickering
11.No RF interference, no buzzing noise.
12.No hazard of mercury or lead entering the environment
13.Easy in stallation
14.No dangerous of glass broken
LED Lighting Tube T5 CE RoHS TUV ETL t5 Bracket Lamp Description:
1.Living room, bedroom,kitchen, washroom;
2.School, university, hospital,hotel;
3.Conference,meeting room, show room,showcase;
4.Commercial complexes;
5.Factory,plant,warehouse,office;
6.Supermarket,department store.
Images:
FAQ:
What certificates do you have for your products?
ISO
- Q: Ordinary fluorescent lamp ballast can be replaced with led daylight lamp tube
- In the process, the ballast is torn down, and the two broken wires in the ballast are connected directly to the wire by the color of the broken end wire. Red is red. The other two colors are connected. Remove the regenerator. The broken line between the two ends of the regenerator needs to be reconnected and wrapped in insulation tape
- Q: What about the quality gap between leds?
- You can look at the whole of the lamp tube first, see the mark on the lamp, mark, model, rated voltage, rated power, etc. And then see if the lamp tube is made of fine workmanship, and how it feels.
- Q: The difference between the Ledt5 lamp and the temperature 3000k and 2700k
- The color temperature of 300K is not very different, with the naked eye, it is very difficult to distinguish, using the instrument test · · the color temperature is high, the color is white, the color temperature is low the red, 6000-6500K is the positive white
- Q: Does a fluorescent lamp change an led light to change a light tube only?
- No, lED tubes do not use a ballast starter.You need to remodel the original fluorescent lamp holder.
- Q: The notice of LED daylight lamp tube
- Without ultraviolet light, no LED lights will not produce ultraviolet light, so unlike traditional lamps, there are a lot of mosquitoes around the light source. The room will become cleaner and cleaner. A voltage adjustable 80v-245v traditional fluorescent lamp is lit by a high voltage released by the rectifier, which cannot be lit when the voltage is lowered. LED lamps can be lit in a range of voltages, and can also adjust the brightness
- Q: What causes the red light on both ends
- Several reasons, the inductance ballast may be neon bulb breakdown short circuit, the shunt capacitance in the starter or not the capacitance may be a bubble in the bimetallic strip jump is not opened, and at the ends of the electronic ballast and the bulb is a resonant capacitance breakdown short circuit, the above cases, red middle not light on both ends of the tube, and is a situation in the middle will be bright, but is not stable, and not the brightest state, is more obvious black on both ends of the lamp aging, conduction resistance big cause filament at start preheating condition at both ends and a red glow, especially the inductance ballast lamp aging at low temperature state is more obvious when starting, the electronic ballast will have original power rectifier filter circuit damage (400 v / 4.7 ~ 10 uf or diode IN4007), also happen when the result in low voltage power supply, replace the corresponding parts.
- Q: How do you measure the flux of the LED fluorescent tube
- Luxmeter, only test fluorescent lamp within a certain range of brightness, the open bright daylight lamp, the light meter to the lights, see distance of one meter range to see how much brightness, two meters how many brightness range. And the best way to test the flux is by using the integral sphere, the data is the most reliable,
- Q: Buy LED fluorescent tubes to see which parameters
- LED fluorescent tube parameters include: LED, total light flux, color temperature, color index, total harmonic distortion, average life, protection grade - etc. As a user of the outside line, it is impossible to know and can not judge its parameters true and false. The only thing you can refer to when you buy a brand is that it is less likely to be fooled.
- Q: LED energy-saving integrated fluorescent lamp tube, in the center has four segment interconnection, when the dark halo light is not known to be that electronic parts failure.
- The so-called integration of T5 and T8 tubes, we can understand from the literal Angle, explained the T5 / T8 I won't do, you should know. Let's look at the integration The so-called integration is lamp and stents are conjoined. From what we often see T5 and T8 are generally and stent can separate the tubes, can say down from the scaffold tubes, and the integration of can't get down. I want to say so, you should be clear!
- Q: What happens to leds if they are not compatible with electronic ballast? What if it's not a bright flash?
- What happens to leds if they are not compatible with electronic ballast? What if it's not a bright flash?
Send your message to us
LED Lighting Tube T5 CE RoHS TUV ETL t5 Bracket Lamp
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 set
- Supply Capability:
- 100000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches