• Hydraulic hose fittings for 4SH DN10 System 1
Hydraulic hose fittings for 4SH DN10

Hydraulic hose fittings for 4SH DN10

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product:

stainless steel rubber hose ferrules

Size:

1/4" --- 4"

Material:

AISI 304, 316, 316L, 201, 310, 430 …

Q235, 20#, ASTM A351-CF8M/1.4408, ASTM A351-CF8/1.4401,

ASTM A216-WCB ... etc

Thread:

BSP, BSPT, NPT, JIC, JIC METRIC, GB METRIC, ORFS… etc

or as per customer’s request.

Type:

One piece hose fitting, Swaged hose fitting, Interlock hose fitting.

Degree:

45 degree, 90 degree, 180 degree.

Pressure:

3000 psi, 6000 psi, 9000 psi.

Certificate:

ISO 9001:2008, CE … etc

Capacity:

50000 tons/year

Package:

Products with plastic cover, Packaged in plastic bag, Plastic bags in

carton boxes, Carbon boxes on wooden cases or wooden pallet with

Iron belt or as per customers' request.

Note:

Standard or Non-standard as per sample or drawing are all available.

Q: High pressure hose K type joints KJR32 and KJR31.5D what is the difference between ah, please give us a answer,
K type joint has the distinction between national standard and German standard. In general, 32 and 38 tubes are used more often. The joints used on 32 of the tubes are KJR32 and KJR31.5D. 38. The joints used on the tubes are KJR38 and KJR B40
Q: Why should the high pressure hydraulic tube peel off the outer skin?
High pressure hose is generally relatively thick, there are steel wire layer, the purpose of peeling is to connect the tooth and steel layer close combination, the joint is more solid. But not all high-pressure hose needs peeling. Now many large companies do not need peeling. For example, pike.
Q: Can the high-pressure rubber hose be followed by water pipes? Will it be poisonous?
The problem should also not large, if it is stored for a period of time in the yard, first put best water again, after all, is not a food container rubber material, inside some substances will dissolve gradually, and there is a water purifier water generating reaction of some harmful substances.
Q: Is there a tolerance standard for rubber tubes in length?
Just think, in the use of the tube, is the important dimension of diameter and wall thickness of the pipe, a little a little long, short should not affect the use, especially the rubber tube, right?! so imagine, rubber tube should not have standard tolerances in length (requirements).
Q: How can the rubber joint be classified according to the range of temperature?
Temperature resistance, suitable for operating temperature above 80 degrees in the transmission pipeline. Special rubber flexible joint is suitable for special pipeline system in the environment of oil, ozone, strong acid and alkali.
Q: What is the essential difference between rubber expansion joint and rubber joint?
The expansion joint is also called expansion device, expansion joint and compensator. It is divided into several types, such as ripple compensator, sleeve compensator, rotary compensator and square natural compensator, and also has intubation type expansion joint. Among them, the corrugated compensator is more commonly used, mainly to ensure the safe operation of the pipeline, and has the following functions: 1.. Compensating the axial, transverse and angular thermal deformation of the absorption pipeline. 2. vibration absorption equipment to reduce the impact of equipment vibration on the pipeline. The deformation of the pipeline 3., absorption of seismic subsidence.
Q: Hose wire is it? What's the function?
It is used to make the skeleton material of high pressure hose, and increase the pressure resistance of the high-pressure hose.
Q: What are the categories of hose?
According to the compression status: pressure hose; suction hose; pressure suction hose (drain suction hose)
Q: Is the rubber pipe joint installed in the middle of the pipe and pump for shock absorption?
Control the noise produced by parts of machinery, equipment, and equipment. The pump foundation of the new pump house should adopt heavy weight to prevent vibration from producing noise. Vibration isolation should be set up with rubber vibration isolating pads to reduce vibration noise. Each pump unit shall be provided with a foundation to prevent resonance. Use "soft" connection as far as possible in the suction pipe and pressure pipe of the pump. Periodic maintenance problems, such as packing leakage, equipment parts loose, serious wear and tear of equipment parts, mechanical vibration and so on, should be repaired in time, thereby reducing noise.
Q: Installation of rubber flexible joint
The installation should be away from the heat source, strictly prohibit the use of media does not meet the requirements of this product.Application scope: because the flexible rubber flexible connector has good comprehensive properties, mainly used for lifting and transporting of raw water and sewage, power plant and water circulating cooling water, condensate water pipeline, metallurgical industry, chemical chemical industry transportation, petrochemical industry, cooling, dilution and other industries flexible connection length the distance between the pipeline. Because of its high wear resistance, rubber is also suitable for the low temperature transportation of granular and powder and steam in all industries.