0.6M/0.9M/1.2M/1.5M Led T8 Tube Led Light Led Tube Light
- Loading Port:
- Shanghai
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 100000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
0.6m/0.9m/1.2m/1.5m led t8 tube, led light, led tube light
1).0.6m/0.9m/1.2m/1.5m
2) Diameter: 28mm
3) Color temp:3000K-7500K
4) View angle: 300°
5) Base: G13
6) Factory
Our LED tubes are made up with super brightness SMD LEDs, and using hi-tech light diffuser,no glare,T8 specs,easy installation, inner high efficiency constant current driver, with less degradation and 30000hour lifespan replacing T8,T10 fluorescent lamp,brighter than fluorescent lamp,better than most similar product.
Specification of led t8 tube
ITEM NO. | AGLED10 T8 PC | AGLED14 T8 PC | AGLED18 T8 PC | AGLED22 T8 PC | ||
Length(mm) | 600mm | 900mm | 1200mm | 1500mm | ||
Diameter(mm) | 26mm | 26mm | 26mm | 26mm | ||
Wattage(w) | 10w | 14w | 18w | 22w | ||
LED chip type | 2835 | 2835 | 2835 | 2835 | ||
LED chip brand | Epistar | Epistar | Epistar | Epistar | ||
Light output (Lumens) | 800LM(daylight) 700LM(warmwhite/ coolwhite) | 1100LM(daylight) 900LM(warmwhite/ coolwhite) | 1500LM(daylight) 1300LM(warmwhite/ coolwhite) | 1800LM(daylight) 1600LM(warmwhite/ coolwhite) | ||
Material | PC | PC | PC | PC | ||
COLOR TEMP | 3000K—7500K | 3000K—7500K | 3000K—7500K | 3000K—7500K | ||
Power Supply | AC 110,220V,85~265V | AC 110,220V,85~265V | AC 110,220V, 85~265V | AC 110,220V,85~265V | ||
Working frequency | 50~60Hz | 50~60Hz | 50~60Hz | 50~60Hz | ||
LED View Angle | 270° | 270° | 270° | 270° | ||
Working Temp | -20---+40° | -20---+40° | -20---+40° | -20---+40° | ||
Working humidity | <90% | <90% | <90% | <90% | ||
Long Life | 30000H | 30000H | 30000H | 30000H |
Advantages of led t8 tube
1).Energy saving. LED lights are more economical than fluorescent lamps.
2). Long lifespan. LED lights have longer life, 30000-50000hours.
3).High brightness. With SMD and constant drive, LED lights possess super brightness.
4). Environmental protection. Mercury free
5).Quick delivery. We are the factory experienced in LED lights production
Trade Conditions of led t8 tube:
1). T/T, 30% deposit and balance before shipment,L/C
2). Transportation: shipment from ningbo
3). Lead time: 25-35 days after the deposit
4). Sample is available
5). Discount: we offer discount for big quantity.
Delivery time of led t8 tube:
For sample, 4-8 days.
For order, 25-35 days after the deposit.
Transportation: by sea, by air, by DHL.TNT.SF
Quality Control of led t8 tube:
100% of the tubes will be tested and keep lighting to test its quality reliability , and we will also test its temperature. Each lamp should pass all these QC procedures before shipping to customer.
Our services:
1.Sample available: we can provide the samples to customers for compare or test. Also we can produce samples according to customers' request.
2. OEM and ODM are acceptable.
3.Your inquiry will be replied with 24 hours.
4.Your design and idea will be kept in confidential.
Applications of led t8 tube:
1).Hotel
2). Conference / Meeting rooms
3). Factories & Offices
4).Commercial Complexes
5). Residential / Institution Buildings
6). Schools, Colleges & Universities
7). Hospitals
8). Places where need energy saving and high color rendering index lighting
- Q:What is the minimum starting voltage for the fluorescent tube?
- The minimum maintenance of a fluorescent tube is 100V volts. 2 · the fluorescent lamp is in qi hui instant, the rectifier load voltage is 800 volts. (the function of the ballast). This 800 volt voltage is transient and can be observed with a digital oscillograph, and the 800v voltage is observed through the digital oscilloscope. I don't have any real data.
- Q:How many lumens is the T5 bulb of 18W
- The fixed bar is still rolling. Let's try a VGA line, if I can't do that, that's the problem of the screen itself. Like screen drive or line problems, not the LCD panel itself.
- Q:The T8 nominal 36W standard daylight bulb is only 18W
- This problem is the output power of the ballast for not doing enough, main is not the problem of power factor. For the electronic ballast, the output of active power is low, requirements for the switch tube is low, can use low or inferior triode, such costs are lower. In addition, the output inductor can also be less a few rounds of copper wire, cost is low. So do electronic ballast to make money. The upstairs have their own design of electronic ballast
- Q:The difference between LED and fluorescent lamps
- LED is a solid-state light source that has a long life and is environmentally friendly and efficient, and leds are now safer.
- Q:The LED T5 daylight lamp can be used for how long
- At the low end of the two years, the five years must be high-end, the high-end price is at least more than two times the lower price, if you buy the lower price, you must have a problem for 5 years
- Q:Fluorescent lamp double lamp tube wiring method
- Leds that do not normally require special orders are mostly built with built-in power, which is directly available. Most can only need to remove the starter on the traditional stent line (is a cylinder bracket highlighted below) mount tubes can be used, if not yet so could you use the stent is a relatively new "electronic" will be a little trouble need you open the stents to get inside the ballast also take off to the inside of the line directly connected to the utility, LED bulb is directly at the mains. Of course, if you understand the circuit and you're not afraid of trouble, it's advisable to remove the "regenerator", because the "ballast" is a power drain.
- Q:Put on the new light bulb, why the lamp still not bright
- Does your fluorescent lamp use a inductive ballast or an electronic ballast? Is the newly installed lamp tube not bright or filament red but unable to start? If the inductor is completely unlit, check to see if it is installed
- Q:Why does the led fluorescent tube have water vapour in it? What causes it?
- The starter down. When the regenerator was knocked down, my home was my own scissors and cut off the ends of the two ends of the regenerator. Then attach the severed head to the insulation tape. search Put the base back to the original. The head of the LED fluorescent tube will be plugged into the base current
- Q:A 30-watt light bulb can be used for a change of LED lamp
- Replace the led tube with rewiring; The original fluorescent lamp ballast is usually removed, and the led tube is a single terminal connection or a double end connection. If you look at the packaging or instruction of the led tube, there is a connection method.
- Q:Homemade studio, what's the light? What light tube, cold light, warm light
- Homemade studio, the proposal USES small volume, energy conservation and environmental protection of the LED lamp, T5 and T8 is right choice, but it is best to choose the warm light, so that better color rendering.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
0.6M/0.9M/1.2M/1.5M Led T8 Tube Led Light Led Tube Light
- Loading Port:
- Shanghai
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 100000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords