1.Structure of Gate Valve Description

A gate valve, also known as a sluice valve, is a valve that opens by lifting a round or rectangular gate/wedge out of the path of the fluid. The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. For extremely thick fluids, a specialty valve often known as a knife valve is used to cut through the liquid. On opening the gate valve, the flow path is enlarged in a highly nonlinear manner with respect to percent of opening. This means that flow rate does not change evenly with stem travel. Also, a partially open gate disk tends to vibrate from the fluid flow. Most of the flow change occurs near shutoff with a relatively high fluid velocity causing disk and seat wear and eventual leakage if used to regulate flow. Typical gate valves are designed to be fully opened or closed.When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low friction loss.

 

2. Main Features of the Gate Valve

• Valve body cavity using non-toxic epoxy resin,both inside and outside flashboard completely is coated with rubber

•  Free of water pollution

• High manufacturing accuracy

• High strength

• Environmental protection and energy saving

• Good visual effect

 

3. Images

 

Gate Valve Non-rising Britain Standard Ductile Iron

Gate Valve Non-rising Britain Standard Ductile Iron

Gate Valve Non-rising Britain Standard Ductile Iron


4. Gate valve Specification

 Gate Valve Non-rising Britain Standard Ductile Iron

5.FAQ

1. What's are the characteristics of gate valve?

The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. 

2. What is the work principle of gate valve

 The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. 

3.  What is the structure?

Bonnets provide leakproof closure for the valve body. Gate valves may have a screw-in, union, or bolted bonnet. Screw-in bonnet is the simplest, offering a durable, pressure-tight seal. Union bonnet is suitable for applications requiring frequent inspection and cleaning. It also gives the body added strength. Bolted bonnet is used for larger valves and higher pressure applications.


Q: What is the difference between the cut-off valve and gate valve, the general will use the cut-off valve instead of gate valve
Stop valve and gate valveThe working principle is different. The stop valve is an upward stem type, and the handwheel rotates and rises with the stem. Valve is hand wheel rotation, stem upward movement. Flow is not the same, the gate valve requires full open, the cut-off valve is not the same. The gate valve has no inlet and outlet direction requirements, and the cut-off valve has the required inlet and outlet!Gate valve and stop valve are shut-off valve, is the most common two valves.From the exterior, the gate valve is shorter than the cut-off valve, especially the bar valve needs a higher height space. Valve sealing surface has a certain degree of self sealing capacity, its spool depends on the media pressure tight contact with the valve seat sealing surface, to achieve tight leakage. Wedge gate valve spool angle is generally 3~6 degrees, when forced to shut down excessive or temperature changes of the valve core is easy to die. Therefore, high temperature and high pressure wedge gate valve, in the structure have taken certain measures to prevent spool stuck. The valve in the opening and closing valve and valve seat sealing surface contact and mutual friction is always so easy to wear sealing surface, especially in close off the valve, the valve before and after the great pressure, sealing surface wear is more serious.
Q: What type of flange does it fit with the gate valve?
This depends on the type of gate valve, valve standards are marked with matching flange standards. Different types of flanges for different gate valves are also different.The flange of General GB gate valve is GB/T9113 series.
Q: greater than DN50 of the pipeline butterfly valve?
Have not heard of this requirement, before the ball valve and butterfly valve quality is rarely used now are good, can be used, but not easy to control the flow valve butterfly valve can close more time-saving, fluid resistance of small. HVAC branch pipe, to flow control, so the choice of gate valve and cut-off valve is more reasonable, and now choose a ball valve is also a lot.
Q: Gate valve z45h-10dn250 length of the body?
Z45h-10dn250 body length L=330mm, this valve is hidden bar, elastic seat, sealing gate valve, gate lining, lining fluorine, belong to soft seal
Q: What is the difference between Z41X gate valve and Z45X gate valve?
All flange soft sealing gate valve, but 41X is Ming bar, 45X is dark pole
Q: What is the wedge type gate valve wedge is what mean
According to the gate can be divided into the form of parallel wedge type. (1) wedge type gate. Wedge type gate the sealing surface of a certain angle with the vertical center line of the gate, the size of angle depends on the medium temperature and diameter size. General medium temperature is higher, and the greater the inclination angle is bigger, in order to prevent the temperature change when the gate is stuck, unable to open. Wedge gate sealing than the parallel well.
Q: What are the structural differences between parallel and wedge valves?
The double gate is pushed aside so that the sealing surface of the valve gate is tightly sealed with the valve body. These double gate parallel gates are mostly used on low pressure pipelines such as small pipelines. Parallel gate valves are also available with single gates, but are rare.That the sealing surface has a certain angle with the vertical center line, bearing higher medium temperature valve, angle the greater the possibility to reduce the temperature when wedged gate rice.Wedge gate valve single, double all.
Q: What is an inverted seal gate valve?
The inverted sealing gate valve is provided with an inverted sealing device, and when the valve is fully opened, an inverted seal is formed, and the filling can be changed under the normal operation of the system.
Q: What is the difference between the cut-off valve and the gate valve?
When opening and closing, the valve core and valve seat sealing surface always contact and rub each other, so the sealing surface is easy to wear, the valve is close to shut down, the pressure difference between the pipe is very large, so that the sealing surface wear more serious.Gate valve and stop valve advantages and disadvantages:Valve is the advantages of small flow resistance, the media can flow in two directions, but there are tall, complex structure, sealing surface easy to wear shortcomings. The flow resistance of the gate valve is 3-5 times that of the gate valve. Open and close to shut down in order to seal the valve, the valve is completely closed when in contact with the sealing surface, the sealing surface wear is very small, because the flow of the main actuator with large valve should pay attention to adjust the torque control mechanism.
Q: Why does the centrifugal pump start and stop in the case of closing the gate valve?
Centrifugal pump to close the gate valve in the case of the start: the centrifugal pump power increases with its flow rate, when the flow is zero (valve closed), the minimum power to operate. Start the valve off from the angle of the motor. If the valve is started, the motor itself to start the current is larger, coupled with the power of the pump is also large, easy to cause the motor over-current trip, serious will burn the motor.