Floor Drain
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 300 Pieces pc
- Supply Capability:
- 50000 Piece/Pieces Per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.H59 and H65 high quality brass
2.Elegant,firm, bright and clean
3.Chrome plated and the thickness up to 50 micrometers
Floor drain
No. | 8801 Floor drain |
Material | H59 and H65 brass |
Size | 9.5*9.5*3.5 cm |
N.W | 192 g |
Surface treatment | chrome plated |
Application | for family bathroom,hotel bathroom and so on |
Test | Acetic acid salt spray test |
Package | Inner box size : 9.5*9.5*3.5 cm |
In general,we use carton with neutral packing and in order to meeting your needs,your requirements also acceptable. | |
MOQ | 300 pcs |
OEM and ODM | Acceptable |
Certification | ISO9001:2008 |
After-sale service | 3 years replacement ,5 years warranty |
Payment | 30%TT as deposit start order,and the balance against copy of B/L |
Delivery time | 20-30 days if this goods will be produced after order |
Advantages
Our products | Explanation | |
Materials | H59 and H65 copper | The Kirsite and stainless steel material are apt to rust.The copper will not rust and the H59 and H65 copper is better for making bathroom accessory |
Copper content | the button part≥59% | |
the pipe part≥65% | ||
pipe thickness 0.6-0.8mm | ||
Polishing | use cotton wheel to polish more than 5 times | The cotton wheel polishing can protect the surface of component |
plating | 1.copper layer thickness ≥40 micrometers | The plated layer is up to 50 micrometer and it is beyond European standard |
2.nickel layer thickness ≥6 micrometers | ||
3.chrome layer thickness ≥0.25 micrometes | ||
Acetic acid salt spray test | testing time≥16 hours | The eligible grade is 7,the higher grade, the higher corrosion resistance |
grade≥10 | ||
After-sale services | 3 years replacement and 5 years warranty | Bathroom brand-name products in China |
- Q: Bathroom leaks, toilet wash basin flush down, floor drain will take the water up, you can flow down, is very slow? why? Hurry
- Find a dredge to solve the water or to spend five dollars to buy a simple dug
- Q: Bathroom decoration into this, underwater to leak, how to do
- Give you the decoration of the master is definitely a layman, so simple things are not good, the bathroom floor drain is 3 to 5 cm. But also how to do, knocked on the red! Hope to adopt!
- Q: Condensate can be directly discharged to the ground to drain, why should the riser,
- Condensate pipes are generally located in the outdoor air conditioning board.
- Q: I live on the first floor, now use the submarine to leak, but still can not prevent the return of water. I would like to ask, what kind of floor drain in the first floor of the best anti-back water effect? Thank you
- There are two kinds of water leakage and magnetic seal, anti-return to the magnetic seal the best effect. Because the first floor of the water pressure, water seal often can not withstand such a high pressure. It is recommended to use the magnetic seal of the floor drain. Do your home submarine leaks are sealed or sealed? Submarine their home products to promote the quality of life is guaranteed, there should be a direct question to the Advisory or return policy. So I suggest you go to find the submarine dealer, since the commitment is certainly responsible, so better than their own to change it.
- Q: When the water is not blocked, when the bath, sometimes the water will go down, sometimes not to go, there is water when the lid first raised and then covered, the water will go down; turn off the faucet, and then open, the water will not go The. What is the relationship with what? Is the tank too deep? Stress cause Or buckle too short? Find someone to come! Soy sauce bypass!
- Is the tank is too deep, the floor to open the lid to open the mouth of the tank mouth two small gap, and then cover the floor cover, you can normally drain. Pay attention not to get in the end, otherwise the water seal no effect is not deodorant
- Q: I wondered why the water rushed down in the toilet would come out of the floor. Where is it bad, what reason, no blocking
- The toilet did not block, but the toilet connected to the next section of the pipeline blocked, so flush caused by the return, from the ground to return to water.
- Q: Can be the toilet water to the ground leakage of things
- To see what is the water, is the surface of the water, or the bathroom did not leak
- Q: Home new clothes to the ground, that is, the kind of apple, which there can be out of the core, according to the water can go directly, but now must take the core water to go, see no cement, the following if there are Something to plug off the core water will not go directly, how is this going on? Is there any good way?
- If the ground cover to pick up clean up the water may not be able to fall into the water, your home usually more sand, right?
- Q: Floor drain cover does not take down the water slowly on the water on the water and the floor drain will be exposed to dirty?
- Change ground drain, dirty ah
- Q: What is the cause of the installation or the cause of the floor drain?
- Generally do the slope of the drainage pipe to 1% or more, both 1 meter of water pipes, slope to 1 cm above, 3 meters of water pipe slope to 3 cm or more. Because the toilet drain is more concentrated, and the drainage when the shower is a large area, the water can flow around, if the slope is not enough, it is easy in some of the relatively small places where the water or slow drainage phenomenon. So the toilet floor slope must be appropriate, should not be too large should not be too small, if the slope is too large, people standing on the above will feel uncomfortable.
1. Manufacturer Overview
Location | Guangdong,China (Mainland) |
Year Established | 2008 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America 6% South America 9% Western Europe 12% South Asia 3% Domestic Market 70% |
Company Certifications | Guangdong Province integrity enterprises; Bathroom brand-name products in China; Consumer Satisfied brand; China Green taps |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Jiangmen |
Export Percentage | 21% - 30% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 3,000-5,000 square meters |
No. of Production Lines | 8 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | High and/or Average |
Send your message to us
Floor Drain
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 300 Pieces pc
- Supply Capability:
- 50000 Piece/Pieces Per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords