• Fire Fighting Truck with Good Performance System 1
  • Fire Fighting Truck with Good Performance System 2
Fire Fighting Truck with Good Performance

Fire Fighting Truck with Good Performance

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 PCS
Supply Capability:
1000 PCS/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Fire Fighting Truck with Good Performance

Product Details

Basic Info.

Model NO.:SLFF12

 

Type:Tanker

Certification:CCC

 

Volume:12000L

Emission Standard:Euro 4

 

Transmission Type:Manual

Engine Type:4 Stroke

 

Fuel:Diesel

Drive Wheel:4×2

 

Horsepower:150-250hp

Condition:New

 

Overall Dimensions L*W*H(Mm):8250*2480*3310

Engine Model:Isb210 40 Dongfeng

 

Power:132kw/180HP

Displacement(Ml):5900

 

Water Tank Volume(Cbm):5

Pump Model:CB10/40

 

Flow:40L/S (Pressure:1.0MPa)

Export Markets:South America, Southeast Asia, Africa, Mid East, Eastern Asia

Additional Info.

Trademark:SLCM

 

Packing:Nude Packing

Standard:CCC, BV

 

Origin:Shandong

Production Capacity:300units Per Month

Product Description


Advantage:
1. All trucks are new and be customized to meet all your requirment.
2. All trucks are with 12 months quality guarantee.
 
Payment:
 
1.30% deposit, 70% before shipment.
 
2.100% irrevocable at sight L/C.
 
Leadtime:
 
20 working days after get the down payment.

Spec:


General 

Truck Name 

Fire Truck

Drive Type 

4*2

Gross Vehicle Weight(kg)

15550

Curb Weight (kg) 

8100

Overall Dimensions L*W*H(mm)

8250×2480×3310

Engine

Engine Model 

ISB210 40

Engine Brand 

Dongfeng

Fuel Type 

Diesel 

Power 

132kw/180HP   

Emission Standard 

Euro IV

Displacement(ml) 

5900

Engine Type

6 cylinders in line,water cooling, turbo-charged diesel engine,inter-cooling

Chassis 

Chassis Brand

Dongfeng

Cab

Double row cab

Tire No.

6

Tire Specification 

9.00-20 Nylon tire

Wheelbase (mm) 

4700

Axle No. 

2

Front/Rear Axle Load

5750kg/9800kg

Steering Wheel

Left hand drive

Gear Box 

6 speed forward with 1 reverse, manual  

Brake 

Air brake

Radiator

Suitable for tropical climate

Water Tank

Water Tank Volume(m³)

5.0

Water Tank Material

High quality Q235

Tank Thickness(mm)

Bottom:4mm,Head:3mm;Side:3mm,Top:anti-skid checkered plate,Anti-wave plate:3mm

Fire Pump

Pump Model

CB10/40

Flow

40L/s (Pressure:1.0MPa)

Fire Monitor

Monitor Model

PS40 

Flow

40L/s (Pressure:1.0MPa)

Range

More than 50m


Rotation Angle

Horizontal:360°,Pitch angle:-30°to 80°

Fire Fighting Truck with Good Performance

Fire Fighting Truck with Good Performance


Q: What is the minimum turning radius of fire lane?
The turning radius of light series fire engines is greater than or equal to 7m, and the turning radius of the series fire engines is larger than or equal to 9m, and the turning radius of the multiple fire engines is greater than or equal to 12m.Fire lane shall comply with the following requirements.(1) the fire lane width and clearance height should not be less than 4 meters, for the fire to stay open the slope should not be greater than 3%.
Q: Social morality and fire cut
Forty-seventh fire trucks and boats to perform fire fighting or emergency rescue mission, under the premise of ensuring safety, without driving speed, driving route, driving direction and traffic signals, ships and other vehicles, pedestrians should be given
Q: What's in the fire engine?
Factory, warehouse, storage yard, storage tank area and large public building fire lane setting requirementsAccording to the fire squadron in the fire fighting practice reflect the larger area of the factory, warehouse, yard, tank fire, burning fast, fierce fire, fire fighting over a long period of time, if there is no fire ring lane and Esplanade, is bound to cause fire vehicles not only into, is bound to cause blockage, so that fire engines to near the fire, therefore, factories and warehouses should set the fire lane. A a, B and C plant covers an area of over 3000 square meters or a B C warehouse covers an area of over 1500 square meters, for the passage of fire engines and a width of not less than 6m of the Esplanade set along the two long side. Flammable and combustible materials, open storage yard area, liquefied gas storage tank area, a, B, C liquid storage area shall be provided with fire lanes or flat spaces for fire engines which are not less than 6m in width.More than 3000 seat stadium, more than 2000 seats in the synagogues and covers an area of over 3000 square meters of exhibition hall and other large public buildings, because the construction of large volume, large area, and personnel intensive, in order to facilitate the occurrence of fire fighting and evacuation, are advised to set up a ring of fire lane.
Q: How to arrange the fire lane in the multi story public building with inner courtyard?
Two, more than 3000 seat stadium, more than 2000 as the synagogue and covers an area of more than 3000m - the exhibition hall and other public buildings, are advised to set up fire ring road.Closed courtyard of the building, such as the short side length of more than 24m, should be put into the inner court of the fire lane.
Q: Fire brigade dispatched, how many dozen fire engines in the end is how big?
The fire inside the car there is a reserve water tank, fire hose, fire is also equipped with special equipment such as fire axe, fire wrench, shovels, buckets, fire extinguishers, and a series of emergency equipment, fire vehicle is also equipped with a ladder for high-altitude rescue.Stationary fire pump, mobile fire pump, water hose, water gun, fire hydrant, spanner, shaped water hose, water separator, lighting lamp, etc.. Above are ordinary equipment that can not be used in ordinary water tanks and fire engines. Like rescue cars, foam fire engines...... And other sophisticated equipment, there will be many.
Q: What is the standard slope of the fire lane?
Attached to the provisions of:4.3.1 longitudinal slope of road1 control indexes for longitudinal slope of residential area are shown in table 4.3. 1.2, the base motor vehicle lane is connected with the urban road. When the slope is large, a buffer section should be set up, and the urban road space should not be occupied.3 in the difficult areas with large topographic gradients, the longitudinal slope of the road should be no more than 11%, the slope length should not exceed lOOm, and the road surface should be anti skidding measures.
Q: What is the standard slope of the fire lane?
4 when the terrain elevation large base road longitudinal slope and slope length is more than 10%, more than 30m, should be set on foot ladder on one side of the road, every step of not less than 3, each stairway rose 1.2 ~ 1.5m should set the rest platform width not less than 1.5m; ladderway continuously increases more than 5m, should be set the rest of the platform. Should also set the turning platform, its width is not less than the width of the ramp stairway, and attached to a bicycle ramp beside.5, the pedestrian road at all levels of the residential area should consider barrier free design, the sidewalk longitudinal slope should not be greater than 2.5%, in the pedestrian walkway, steps should be equipped with wheelchair ramps and handrails.There is a table in the above regulations, can not paste
Q: What is the fire water pressure of fire engines?
The low pressure water pump on fire engines generally has a rated operating pressure of 1.0MPa. Medium pressure is generally 2.0MPa
Q: What is an annular fire lane?
fire lane6.0.1 street should be considered within the road fire trucks, and the distance between the center of the road should not be greater than 160.0m. When the length of the building along the street portion is greater than 150.0m or the total length is greater than 220.0m, a fire lane through the building shall be provided. When there is a problem, the ring fire lane should be provided.
Q: What kind of driving license can drive a fire engine?
In accordance with the Ministry of public security, "motor vehicle driver's license application and use regulations", fire engines need B2 driver's license.Fire engines belong to large, heavy and medium-sized special operation vehicles, and should have large freight car driver's license, that is, B2 level driver's license.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches