• Fire Truck 2000L Isuzu 4X2 Small System 1
  • Fire Truck 2000L Isuzu 4X2 Small System 2
Fire Truck 2000L Isuzu 4X2 Small

Fire Truck 2000L Isuzu 4X2 Small

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 PCS
Supply Capability:
1000 PCS/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Fire Truck 2000L Isuzu 4X2 Small 


Product Details

Basic Info.

Model NO.:QL1073

 

Type:Tanker

Certification:ISO9000, CCC

 

Volume:<3000L

Emission Standard:Euro 4

 

Transmission Type:Manual

Engine Type:4 Stroke

 

Payload:5t

Fuel:Diesel

 

Drive Wheel:4×2

Horsepower:<150hp

 

Condition:New

Chassis Brand:Isuzu 100p

 

Cabin:Double Row

Drive Type:4X2 Optional 6X4 4X4 6X6 8X4

 

Engine:72kw / 98HP

Gearbox:5-Speed

 

Dirve Axle:4tons

Water Tank Capacity:2000L

 

Water and Foam Tank:Water 1500L Foam 500L

Equipment:Pressure Fire Pump

 

Export Markets:Global

Additional Info.

Trademark:SUNY

 

Packing:After Waxing by Container, RO-RO, Bulk Freighter

Standard:ISO&CCC

 

Origin:Hubei Suizhou

Production Capacity:500 Unit / Month

Product Description

Products Technical Specification
Brand-SeriesISUZU
Product Name4*2  Fire truck 
Chassis ModelQL1073HWPY
Emission StandardEuro 4
Fuel typeDiesel
Cabin 100P,Double row
Whole vehicle 
main dimensions (mm)
Overall dimensions (L×W×H) 6260*1980*2780
Wheel base       3360
Front overhang       1015
Rear  overhang    1755
Min. ground clearance 350
Weight data (kg)G.V.W6550
Curb weight (chassis)4350
Max payload4500
Whole vehicle 
main performance
Max. speed (km/h)95
Max. slope of climb (%)30
EngineModel4JB1CN
Maximum power72kw / 98hp
Number of cylinders4
Displacement (L)2.771
Engine ManufacturerISUZU ENGIEN
TransmissionModelMSB
Number of gears5 forward gears& 1 reverse  
Axle Rear Load capacity (ton)4T
SuspensionLeaf spring8/6+5
Steering Wheelleft/right hand driveLHD
Brake systemService brake Air braking
Electric deviceRated voltage24V
Tyres & Quantity7.00-16 & 6+1
Tank Description
Tank capacityWater:2000L
Water:1500L
Foam:500L
Fire pumpModelCB10/30
Flux30L/S 
Pressure1.0Mpa
Fire fighting nozzleModelPP24
Pressure1.0Mpa
PTOSandwich PTO, splashing-type lubricate, can put out fire when driving.
Material of carriageCarriage is made of high quality steel and Aluminum embossed sheet
ColorThe whole vehicle is red for fire fighting, 
there are white in the middle of truck in accordance with the whole truck.
Optional Configuration (√:Standard Equipment  o:Optional   ×:Not Available)
Air Conditioner 
Cab,Half row
Power Steering 
Side bumper
Rear bumper
 Radial tireo

Fire Truck 2000L Isuzu 4X2 Small

Fire Truck 2000L Isuzu 4X2 Small


Q: What documents do you need to drive the fire engine?
The following conditions are required to apply for a B2 driver's license:1, over 20 years of age, under 50 years of age;
Q: How far can fire engines shoot water?
GB 7956-1998 fire engine performance requirements and test methods4.3.1 part of the fire gun performance requirements, which has the corresponding flow and pressure conditions in the corresponding range (30 meters -65 meters)In reality, medium-sized and heavy-duty fire engines are equipped with high pressure fire pumps. Under normal circumstances, the effective range can be more than 80 meters, and the range of individual fire engines and water cannons can reach more than 100 meters
Q: Where should the school fire escape be, inside or outside the school?
The 6.0.10 ring fire lane should have at least two lanes connected to other lanes. The end of the fire lane should be back lane or return field, the return area should not be less than 12.0m * 12.0m; for large fire engines, it should not be less than 18.0m * 18.0m.The fire fighting work site and road surface, the pipes and drain etc. should be able to withstand the pressure of large fire truck.Fire lane can use traffic road, but it should meet the requirement of fire vehicle passing and stopping
Q: Can fire engines be free from traffic restrictions while performing their duties?
The "People's Republic of China Fire Law" provisions of article thirty-fifth: fire engines to implement fire fighting and rescue work or other disaster and accident rescue mission, without driving speed, driving route, driving direction and command signal limit
Q: Fire lane width should be no less than meters
4 for fire engines to take in natural water, fire pool should be equipped with fire lane.5 width of fire lane should not be less than 4.00m. Fire lane from high-rise building exterior wall should be greater than 5.00m, fire lane above 4.00m within the scope of the obstacles should not be.6 end fire lane should have back lane or return field, enter the field should not be less than 15mx15m. The return field of large fire engines should not be less than 18mx18m. The fire lane pipeline and Angou, should be able to withstand the pressure of fire fighting vehicles.7 through the fire lane of the high-rise building, its width and height clearance shall not be less than 4.00m.8, between fire lane and high-rise building, should not set up hinder climbing fire truck operation of trees, overhead pipelines.
Q: What is a fire climbing surface?
High rise housing should be equipped with fire climbing surface, and should meet the following standards:1 tower residential fire climbing surface should not be less than the residential 1/4 perimeter length;A long side length of fire climbing surface 2 unit, corridor style residential residential should not be less than;3 fire climbing surfaces should be close to residential public staircases or balconies and windows;4 side fire climbing surface of the podium, the building height should be no more than 5m, and the depth should not exceed 4m; (new version of code for fire protection canceled podium height limit)5, fire climbing surface should not design large area glass curtain wall6 there is no tall tree that hinders the climb between the climbing surface and the building.7, within the range of the building, there should be a safe exit for the building.
Q: Is there a "fire passage and entrance"?
6.0.9 the net width and clearance height of fire lane shall not be less than 4.0m. For the space where the fire engine stops, the slope shall not exceed 3%.Barriers between fire lane and factory building (warehouse) and civil building should not be set up to hinder the operation of fire engines.The 6.0.10 ring fire lane should have at least two lanes connected to other lanes. The end of the fire lane should be back lane or return field, the return area should not be less than 12.0m * 12.0m; for large fire engines, it should not be less than 18.0m * 18.0m.The fire fighting work site and road surface, the pipes and drain etc. should be able to withstand the pressure of large fire truck.Fire lane can use traffic road, but it should meet the requirement of fire vehicle passing and stopping.You look at you with the actual area above can meet, join can not meet, you can complain to the local public security fire department, fire department after receiving complaints, should immediately check to the scene, at the same time to reply to the complainant.
Q: What's the fire passage (size)?
Article 6.0.8 a fire lane shall be provided for natural water sources and fire pools for fire engines.Article 6.0.9 of the fire lane width should not be less than 3.5m, over the road in case of pipe rack, Zhanqiao and other obstacles, the height of not less than 4m.Article 6.0.10 an annular fire lane shall have at least two lanes connected to other lanes. The end fire lane shall be provided with a return lane or a return field not less than 12m * 12m. The size of the return field used for large fire engines shall not be less than 15m * 15m.The fire lane and Angou pipeline should be able to withstand the pressure of large fire truck.Fire lanes can take advantage of traffic roads.
Q: Fire lane from the outside wall of the building should not be less than 5m, should not be greater than 15m, from what norms?
6.0.2 has a closed courtyard or patio buildings, while the short side length is greater than 24.0m, the fire lane should be set to the inner courtyard or patio.6.0.3 has a closed courtyard or patio buildings along the street, should be pedestrian streets and communicated inner courtyard (use staircase), the distance should be less than 80.0m.6.0.4 in the fire lane across both sides of buildings or buildings into the courtyard, should not affect the security settings of the evacuation or fire truck traffic facilities.
Q: What is an annular fire lane?
6.0.2 has a closed courtyard or patio buildings, while the short side length is greater than 24.0m, the fire lane should be set to the inner courtyard or patio.6.0.3 has a closed courtyard or patio buildings along the street, should be pedestrian streets and communicated inner courtyard (use staircase), the distance should be less than 80.0m.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords