Double compression armored brass cable glands IP68
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 pc
- Supply Capability:
- 1000000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
SH-BDM-22 Double compression cable gland IP68
Materials:Brass or stainless steel ,brass with nickel planted
Sealing materials:Silicon rubber,Neoprene,Teflon,PA6
Explosion mark:Exd IIC Gb/Exe II Gb/Ex tD A21 IP68
Fireproof grade:V0(UL94)
Environment condition:Zone1,Zone2 IIA-IIC Explosive gas atmosphere,Strict21,22 inflammable dust environment,it is Widely used in oil extraction, refining, chemical, military and so on hazardous environment places cable clamping and sealing.
SH-BDM-22-01 M20*1.5A,NPT1/2A,G1/2A
SH-BDM-22-02 M20*1.5B,NPT1/2B,G1/2B
SH-BDM-22-03 M20*1.5C,NPT1/2C,G1/2C
SH-BDM-22-04 M25*1.5B,NPT3/4B,G3/4B
SH-BDM-22-05 M25*1.5C,NPT3/4C,G3/4C
SH-BDM-22-06 M32*1.5B,NPT1B,G1B
SH-BDM-22-07 M32*1.5C,NPT1C,G1C
SH-BDM-22-08 M40*1.5B,NPT1-1/4B,G1-1/4B
SH-BDM-22-09 M40*15C,NPT1-1/4C,G1-1/4C
SH-BDM-22-10 M50*1.5B,NPT1-1/2B,G1-1/2B
SH-BDM-22-11 M50*1.5C,NPT1-1/2C,G1-1/2C
SH-BDM-22-12 M63*1.5B,NPT2B,G2B
SH-BDM-22-13 M63*1.5C,NPT2C,G2C
SH-BDM-22-14 M75*1.5B,NPT2-1/2B,G2-1/2B
SH-BDM-22-15 M75*1.5C,NPT2-1/2C,G2-1/2C
SH-BDM-22-16 M90*1.5,NPT3,G3
SH-BDM-22-17 M110*1.5,NPT4,G4
Customization is accepted!!
Welcome to contact with us if some requirement.
- Q: 1000 kW 600 m cable to use much
- 1000kw ah that with three groups of 400-ping line should be no problem
- Q: Is the cable head made of every building?
- Generally have every building floor wiring closet must be connected to the big cable. The big cable comes in to do the cable head
- Q: What is the meaning of PG + digital markings for electrical wiring?
- If no color distinction, 100 meters after you know which line of the fire line which line? The
- Q: 3 by 16 cable is a few flat? How? That 5 by 16?
- Is the power directly out of the CPU power supply line or on this basis and added the extension line
- Q: How much of the cable with the switch?
- The switch is not selected according to the cable and is selected according to the current. The cable is determined by the size of the power (converted to current) and the distance from which the distance is far. The greater the power distance, the greater the cross-sectional area of the required cable. For example: 15KW motor selection cable current I = P / 1.732UcosΦ = 15 / 1.732 / 0.38 / 0.8 = 28A if it is close (within tens of meters), copper cable 6 square millimeters, aluminum cable 10 square millimeters. If it is in the distance (a few hundred meters), copper cable 10 square millimeters, aluminum cable 16 square millimeters. If it is long distance (close to kilometers), copper cable 16 square millimeters, aluminum cable 25 square millimeters. The switch is regardless of distance, completely based on the load current to choose, generally according to the load current of 1.5 times to 2 times to choose.
- Q: Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
- If you want to ensure that the transmission medium does not cause the signal to cause attenuation and interference, fiber transmission or balanced cable transmission is the best solution. If you need fiber transmission, the cost is high because you need to buy digital fiber converters and digital audio decoders and related equipment, but this can be to the maximum extent to ensure the integrity of the signal and the smallest noise interference. If you want to use low-cost transmission can also be used directly to the cable transmission, but must use a balanced interface for transmission, and with 2-core shield or 3-core, 5-core shielded cable for transmission. This can also ensure the clarity of the signal to the maximum extent, but do not eat hungry thirsty 丨 Chicken check blood sausage is too long. No matter how good the cable will be attenuated, the size of the attenuation will directly affect the signal quality and signal integrity. So the transmission distance with the balance line can not be too far. More than two kinds of transmission methods than the existing single-line transmission is much better, if you are a fever-level players, I suggest you use fiber transmission. But if your power amplifier or your source signal to noise ratio is not high, I do not recommend you use fiber transmission, because even if the quality of fiber transmission no matter how good your source is not high, then it does not make sense The
- Q: Can the main cable be aluminum cable? And explain why, thank you!
- Power board problem cost 10 less than the general maintenance received you 150
- Q: 5 air conditioning can be used 4 square cable
- Lengthened low voltage side, the line resistance increases, the voltage drop increases. Reduced load capacity. So that the router due to insufficient supply voltage and can not work properly. It is not allowed to use 9V power supply. Voltage is too high, the router part of the internal power supply increased power, heat increased, it is possible to burn the router. It is necessary to extend the power cord, I suggest you extend the power supply side (220V one end) safe and reliable. Increase the voltage to increase the supply current, in the electrical working voltage range (with the electrical work voltage range) is allowed, too low electrical appliances can not work properly. Too high there is the risk of burning appliances, according to your actual situation, marked 5V0.2A that the router works at rated voltage, so the way to improve the supply voltage is not applicable. So you can only improve the power supply power (that is, you say to increase the power supply current rather than voltage). With the reserve power, it will provide enough current at the rated voltage (the router as a resistor, from I = U / R, you can know the danger of increasing the voltage) need help please message
- Q: The difference between nylon balls and geese and ducks
- If the 2.5 square copper wire for the output extension cable, 20 meters distance, the total resistance of about 2 * 1.7 * 0.2 / 2.5 = 0.272 (ohms), the current maximum 1.8A, the voltage drop is 0.272 * 1.8 = ), The charging voltage is 55-0.5 = 54.5 (volts), a difference of about 1% will not have any impact on the battery. However, the third floor, said Ye Hao, you can put the charger put the debris room, from your house put a 220V power cord down, home and then engage in a switch control. It is best to design a light at home, can intuitively see if the electricity is full. That's better. Design light, teach you a way: to find a bad leakless protector, open there is a coil-like ring-shaped stuff, called zero sequence current transformer, it will be down, be careful, do not put Transformers inside the coil hurt, get down, in the transformer two thin lines connected to a light-emitting diode. And then your 220V power cord line of fire from the center of the sensor through, around 3-5 turns. In this way, as long as there is current flow, the light-emitting diode will be bright, when the charge is over, the charging current is close to zero, the light-emitting diode will be extinguished. You can from the light-emitting diode is lit to determine whether the electric has been filled. I also have an electric bike that is so charged.
- Q: 6 square cable up to how many air conditioning (1.5P)
- 1 square millimeters can flow 4A current, 1KW380V, then the current is about P = UI about 2.6A7KW, 380V, then the current is about 18A, each with the line to share 18/3 = 6A2.5 square mm of copper on it. Of the area need to take . probably 6 level. V is probably 7KW220VI = p / u = 7000/220 = 31A. Then need 10 square millimeters of copper.
Send your message to us
Double compression armored brass cable glands IP68
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 pc
- Supply Capability:
- 1000000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches