Brass Industrial cable gland for unarmored cable IP68
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 pc
- Supply Capability:
- 100000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
Materials:Brass,Stainless steel 304,316
Surface treatment:Nickel planted,Passivation
Sealing materials:Silicon rubber,Neoprene,Teflon,PA6
Explosion mark:Exd IIC Gb/Exe II Gb/Ex tD A21 IP68
Fireproof grade:V0(UL94)
Protection level:IP68 (screwed-on the cap)
Ambient temperature:Static from -60℃ to 100℃,short up to 120℃
Dynamic from -20℃ to 80℃,short up to 100℃ without halide.
Environment condition:Zone1,Zone2 IIA-IIC Explosive gas atmosphere,Strict21,22 inflammable dust environment,it is widely used in petroleum, chemical, warehouse, food, pharmaceutical, military and other electrical cable fixing and sealing.
Entry thread size AG | Acceptable cable detail |
H |
GL |
Hexagon size | ||||
Outer sheath (B) | ||||||||
M | NPT/G | Min | Max | Across flats | Across corners | |||
M20*1.5 | 1/2” | 5.5 | 12.0 | 30.0 | 15 | 24.0 | 27.7 | |
SH-BDM-1-01S | M20*1.5S | 1/2” | 9.5 | 16.0 | 38.0 | 16 | 24.0 | 27.7 |
SH-BDM-1-02 | M25*1.5 | 3/4” | 12.5 | 20.5 | 38.0 | 16 | 30.0 | 34.6 |
SH-BDM-1-03 | M32*1.5 | 1” | 16.9 | 26.0 | 44.0 | 18 | 36.0 | 41.6 |
SH-BDM-1-04 | M40*1.5 | 1 1/4” | 22.0 | 33.0 | 46.0 | 18 | 45.0 | 53.1 |
SH-BDM-1-05 | M50*1.5 | 1 1/2” | 28.0 | 41.0 | 50.0 | 20 | 55.0 | 63.5 |
SH-BDM-1-06 | M63*1.5 | 2” | 36.0 | 52.6 | 64.0 | 20 | 68.0 | 75.1 |
SH-BDM-1-07 | M75*1.5 | 2 1/2” | 46.0 | 65.3 | 70.0 | 20 | 80.0 | 92.4 |
SH-BDM-1-08 | M85*1.5 | “3 | 57.0 | 78.0 | 80.0 | 20 | 95.0 | 109.6 |
Customization is accepted!!
If some requirement,welcome to contact with us.
- Q: Is the cable head made of every building?
- Generally have every building floor wiring closet must be connected to the big cable. The big cable comes in to do the cable head
- Q: What is the meaning of PG + digital markings for electrical wiring?
- If no color distinction, 100 meters after you know which line of the fire line which line? The
- Q: 3 by 16 cable is a few flat? How? That 5 by 16?
- Motherboard and power supply problem, the best way is to try to USB2.0 ban on the use of USB1.1 but will be slower
- Q: How much of the cable with the switch?
- The switch is not selected according to the cable and is selected according to the current. The cable is determined by the size of the power (converted to current) and the distance from which the distance is far. The greater the power distance, the greater the cross-sectional area of the required cable. For example: 15KW motor selection cable current I = P / 1.732UcosΦ = 15 / 1.732 / 0.38 / 0.8 = 28A if it is close (within tens of meters), copper cable 6 square millimeters, aluminum cable 10 square millimeters. If it is in the distance (a few hundred meters), copper cable 10 square millimeters, aluminum cable 16 square millimeters. If it is long distance (close to kilometers), copper cable 16 square millimeters, aluminum cable 25 square millimeters. The switch is regardless of distance, completely based on the load current to choose, generally according to the load current of 1.5 times to 2 times to choose.
- Q: Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
- heat shrinkable casing (MRSG) is a new environmentally friendly halogen-free flame retardant casing, inexpensive products, for wire, cable and wire terminals to provide insulation protection
- Q: Can the main cable be aluminum cable? And explain why, thank you!
- Excretion training is the use of positive reinforcement, that is, a variety of food, toys, the best time to reward
- Q: 5 air conditioning can be used 4 square cable
- Such as the extension line added to the adapter primary (city side) certainly easy to use. Extended by two meters, the router does not start, may be extended wire diameter is too thin, bold wire try. If not, choose 6V2A adapter try, the voltage is too high will burn the router. Increase the current is no problem, just like the computer's power, 300-watt power can be replaced, and small is not OK.
- Q: The difference between nylon balls and geese and ducks
- It depends on the thickness of the wires you use. The thicker the copper wire is, the better. Because the distance will be a voltage drop. So be it, you use a multimeter to look at how long you charge when the output voltage is how much. If you can more than 50 should be no problem. If the voltage is relatively low can change a rough wire, or find a few wires in parallel can also be. I do not know if you can understand it. Even if there is a voltage drop if it is not very powerful should not be the problem, the worst result is the battery charge dissatisfaction. You can try to see how the effect of the day. Certainly will not break your equipment and battery, rest assured it
- Q: How do I ask for cable prices? How many tons is one or more?
- Cable bridge grounding should belong to the protective grounding, grounding resistance at a cross point is not greater than 50 milliohms, no jumper no more than 5 milliohms
- Q: 6 square cable up to how many air conditioning (1.5P)
- 1 square millimeters can flow 4A current, 1KW380V, then the current is about P = UI about 2.6A7KW, 380V, then the current is about 18A, each with the line to share 18/3 = 6A2.5 square mm of copper on it. Of the area need to take . probably 6 level. V is probably 7KW220VI = p / u = 7000/220 = 31A. Then need 10 square millimeters of copper.
Send your message to us
Brass Industrial cable gland for unarmored cable IP68
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 pc
- Supply Capability:
- 100000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords