Brass Industrial cable gland for unarmored cable IP68
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 pc
- Supply Capability:
- 100000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
Materials:Brass,Stainless steel 304,316
Surface treatment:Nickel planted,Passivation
Sealing materials:Silicon rubber,Neoprene,Teflon,PA6
Explosion mark:Exd IIC Gb/Exe II Gb/Ex tD A21 IP68
Fireproof grade:V0(UL94)
Protection level:IP68 (screwed-on the cap)
Ambient temperature:Static from -60℃ to 100℃,short up to 120℃
Dynamic from -20℃ to 80℃,short up to 100℃ without halide.
Environment condition:Zone1,Zone2 IIA-IIC Explosive gas atmosphere,Strict21,22 inflammable dust environment,it is widely used in petroleum, chemical, warehouse, food, pharmaceutical, military and other electrical cable fixing and sealing.
Entry thread size AG | Acceptable cable detail |
H |
GL |
Hexagon size | ||||
Outer sheath (B) | ||||||||
M | NPT/G | Min | Max | Across flats | Across corners | |||
M20*1.5 | 1/2” | 5.5 | 12.0 | 30.0 | 15 | 24.0 | 27.7 | |
SH-BDM-1-01S | M20*1.5S | 1/2” | 9.5 | 16.0 | 38.0 | 16 | 24.0 | 27.7 |
SH-BDM-1-02 | M25*1.5 | 3/4” | 12.5 | 20.5 | 38.0 | 16 | 30.0 | 34.6 |
SH-BDM-1-03 | M32*1.5 | 1” | 16.9 | 26.0 | 44.0 | 18 | 36.0 | 41.6 |
SH-BDM-1-04 | M40*1.5 | 1 1/4” | 22.0 | 33.0 | 46.0 | 18 | 45.0 | 53.1 |
SH-BDM-1-05 | M50*1.5 | 1 1/2” | 28.0 | 41.0 | 50.0 | 20 | 55.0 | 63.5 |
SH-BDM-1-06 | M63*1.5 | 2” | 36.0 | 52.6 | 64.0 | 20 | 68.0 | 75.1 |
SH-BDM-1-07 | M75*1.5 | 2 1/2” | 46.0 | 65.3 | 70.0 | 20 | 80.0 | 92.4 |
SH-BDM-1-08 | M85*1.5 | “3 | 57.0 | 78.0 | 80.0 | 20 | 95.0 | 109.6 |
Customization is accepted!!
If some requirement,welcome to contact with us.
- Q: Is the cable head made of every building?
- Generally have every building floor wiring closet must be connected to the big cable. The big cable comes in to do the cable head
- Q: What is the meaning of PG + digital markings for electrical wiring?
- The best cement and other dry in the closing, because the wet cement contains moisture, can be conductive, dry the probability of conduction less. Pay attention to the wire to maintain integrity, no broken skin, it is best to protect the casing.
- Q: 3 by 16 cable is a few flat? How? That 5 by 16?
- Is the power directly out of the CPU power supply line or on this basis and added the extension line
- Q: How much of the cable with the switch?
- Switch = (2-2.5) current three-phase current = P / 1.732 / 0.38 / 0.8 single-phase current = P / 0.22 / 0.8
- Q: Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
- heat shrinkable casing (MRSG) is a new environmentally friendly halogen-free flame retardant casing, inexpensive products, for wire, cable and wire terminals to provide insulation protection
- Q: Can the main cable be aluminum cable? And explain why, thank you!
- Power board problem cost 10 less than the general maintenance received you 150
- Q: 5 air conditioning can be used 4 square cable
- You do not use the 9V power supply, a long time will burn the router.You'd better measure the original adapter voltage, if you want to extend the power cord, it is best to use a thick line of reliable connection, you can not start now, you can not start Depending on whether the extension line is too thin, causing the voltage drop too much.It is necessary to extend the front end of the adapter can extend the 220V power cord.
- Q: The difference between nylon balls and geese and ducks
- It depends on the thickness of the wires you use. The thicker the copper wire is, the better. Because the distance will be a voltage drop. So be it, you use a multimeter to look at how long you charge when the output voltage is how much. If you can more than 50 should be no problem. If the voltage is relatively low can change a rough wire, or find a few wires in parallel can also be. I do not know if you can understand it. Even if there is a voltage drop if it is not very powerful should not be the problem, the worst result is the battery charge dissatisfaction. You can try to see how the effect of the day. Certainly will not break your equipment and battery, rest assured it
- Q: How do I ask for cable prices? How many tons is one or more?
- As long as the line connected to the corresponding location, that is, audio cable audio and video cable, video cable can be used with the video line.
- Q: 25 square copper cable how much money one meter?
- 3 plus 1 64.13 yuan, 3 plus 2 75 yuan, 4 plus 1 81.38 yuan contact to see my registration name
Send your message to us
Brass Industrial cable gland for unarmored cable IP68
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 pc
- Supply Capability:
- 100000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords