DN100 Gate Valve PN16 from China on Sale
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Structure of Gate Valve Description:
A gate valve, also known as a sluice valve, is a valve that opens by lifting a round or rectangular gate/wedge out of the path of the fluid. The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. For extremely thick fluids, a specialty valve often known as a knife valve is used to cut through the liquid. On opening the gate valve, the flow path is enlarged in a highly nonlinear manner with respect to percent of opening. This means that flow rate does not change evenly with stem travel. Also, a partially open gate disk tends to vibrate from the fluid flow. Most of the flow change occurs near shutoff with a relatively high fluid velocity causing disk and seat wear and eventual leakage if used to regulate flow. Typical gate valves are designed to be fully opened or closed.When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low friction loss.
2. Main Features of the Gate Valve:
• Valve body cavity using non-toxic epoxy resin,both inside and outside flashboard completely is coated with rubber
• Free of water pollution
• High manufacturing accuracy
• High strength
• Environmental protection and energy saving
• Good visual effect
3. Images
4.FAQ
1. What's are the characteristics of gate valve?
The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel.
2. What is the work principle of gate valve ?
The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry.
3. What is the structure?
Bonnets provide leakproof closure for the valve body. Gate valves may have a screw-in, union, or bolted bonnet. Screw-in bonnet is the simplest, offering a durable, pressure-tight seal. Union bonnet is suitable for applications requiring frequent inspection and cleaning. It also gives the body added strength. Bolted bonnet is used for larger valves and higher pressure applications.
- Q: What else, P54140V, 170V? What do they mean?
- P work pressureP54 temperature at 540 degrees of work pressureThe pressure at P54 100 is 540 at the temperature of 100barV valve for chromium molybdenum vanadium steelP54 pressure 140V temperature at 540 DEG C for 140bar valve for chromium molybdenum vanadium steelP54 pressure 170V temperature at 540 DEG C for 170bar valve for chromium molybdenum vanadium steelFrom the JB/T4018 "valve type model preparation method"The standard unit is MPa, but it is usually used in bar
- Q: Gate valve type Z40Y, Z40H letters - what does that mean?
- According to the provisions of the JB/T 308-2004 valve type programming method:Z== gate valve4== connection: flange0== structure: wedge type elastic RAMY== sealing surface material: hard alloyH== sealing surface material: Cr13 stainless steel
- Q: Is the gate valve clockwise or closed?
- In general, the valve is clockwise turn off, in the case of special requirements under the opening.
- Q: Why the valve can only be fully open and fully closed valve can adjust the flow?
- Valve, if adjusted, it is easy to wash the sealing surface, resulting in sealing surface damage.
- Q: Will the water supply and drainage to wear civil air defense gate valve, the use of bright rod or dark rod?
- 3, soft sealing rubber lining valve plate size uniform, interchangeable. Therefore, the soft sealing gate valve will be the direction of development, but also the water supply industry is willing to adopt a valve.
- Q: What are the structural differences between parallel and wedge valves?
- The double gate is pushed aside so that the sealing surface of the valve gate is tightly sealed with the valve body. These double gate parallel gates are mostly used on low pressure pipelines such as small pipelines. Parallel gate valves are also available with single gates, but are rare.That the sealing surface has a certain angle with the vertical center line, bearing higher medium temperature valve, angle the greater the possibility to reduce the temperature when wedged gate rice.Wedge gate valve single, double all.
- Q: Generally, how big is the diameter of the installation flange plate gate valve?
- Under normal circumstances:Flanged gate valves for piping over DN50,DN50 (below) can be made of wire or gate valves, or flanged gate valves (flanged valves or welded gate valves)
- Q: Yes, soft sealing gate valve can reach 25 kilograms, Fujian light valve company has this type of soft sealing gate valveAnonymous browsing | 28 times
- Soft seal butterfly valve seal is good, but can only withstand up to 16 pressure, or the plastic can not stand. A short period of time is OK, and it's also related to the workmanship and quality of the factory. The quality is poor.
- Q: What does the gate valve SZ45X-1.0 stand for?
- A modelModel SZ45T-1.0, especially in DN100 ~ DN300 piping, soft sealing gate valve shall be used
- Q: Fire protection gate valve from the wall how many distance there is no regulation?
- Don't know don't answer. "According to the provisions of article 6.2.13 GB50038-2005" code for design of basement for civil air defense engineering, into or through the door unit between the door closed wall should be set up in the inner side or two nominal pressure pipeline is not less than 1.0MPa, the spool is stainless steel or copper gate or globe valve water pipe from the air enclosure structure. The installation position from the wall should be not more than 200mm.