DBM DEAD BURNT MAGNESITE High Purity Made in China
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m.t.
- Supply Capability:
- 20000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Dead burned magnesite- DBM-
is produced using selected natural magnesite that is purified and is calcined in a shaft kiln.The final product is used for electric furnacefloors and furnace liner tamping.
Main products level :
0-1mm
1-3mm
3-5mm
0-10mm
200mesh (90% through)
325mesh (90% through)
Product feature:
high temperature performance and high-density, strong anti-permeability ability and easy to rapid sintering, very thin sintered layer,good thermal shock stability, strong slag-resistance, long service life and so on.
Product function:
Apply to the construction of bottom and wall of all kinds steel making electric arc furnace and ferroalloy smelting furnace for hot charging of hot metal and second hand steel
Product usage:
Mainly used in producing common magnesite brick, magnesite aluminum brick, magnesite chrome brick, gunning mix, hot patching mix for converter and EAF ect .
Product Advantage:
Our factory produce the products of the Dead-burned magnesite are selected natural magnesite, it is produced by mine-selecting, purifying, calcimine in shaft kiln. It is an ideal material for unshaped refractory material, the final products are used in open hearth furnace, electric furnace bottom and furnace's lining tamping.
MgO ≥ | CaO ≤ | SiO2 ≤ | L.O.I. ≤ | BD ≥ g/cm3 | size mm | |
VT-MGO-DBM 87 | 87 | 2.2 | 7.0 | 0.5 | 3.1 | according to the requirement of customer |
VT-MGO-DBM 90 | 90 | 2.2 | 5.0 | 0.3 | 3.15 | |
VT-MGO-DBM 91 | 91 | 2.0 | 4.5 | 0.3 | 3.18 | |
VT-MGO-DBM 92 | 92 | 1.8 | 4.0 | 0.3 | 3.18 | |
VT-MGO-DBM 93 | 93 | 1.6 | 3.5 | 0.3 | 3.18 |
Picture:
- Q: Who knows about the fire endurance of A grade fireproofing glass doors?
- The fire endurance of A grade fireproofing glass doors should be no less than 3 hours. A grade fireproofing glass doors use common glass of 6 mm. The shock resistance of float glass is about less than 5 min, and that of toughened glass is about 15 to 30 min. Fireproofing glass is classified in accordance with fire rating, the fire endurance of which is usually from 30 to120min, and that of the most common fireproofing glass is 60 to 90min, but now the market is a mixed bag, the so-called fireproofing glass is generally fake ultra-strong tempered glass. Therefore, you should buy the genuine glass with formal certificates, or you will bring yourself great inconvenience, and even more serious consequences.
- Q: What are the fire protection standards of insulation materials?
- According to the three versions of GB8624 (1997,2006,2011), the fire rating of external walls can be basically divided into: A1-, A2-, B1-, B2-, B3-level. The detailed divisions are determined by many technical indicators. It is a very professional and technical long story. Please contact QINGDAO SHANFANG INSTRUMENT CO., LTD for detail information, they are specialized in manufacturing fire rating testing instruments of external walls.
- Q: How to distinguish the fire?rating of rubber and plastic thermal insulation material?
- Fire?rating grading of external wall thermal insulation materials. 1, China's national standard GB8624-97 divides the combustion performance of building materials external insulation materials into the following grade. Level A: Incombustible materials: Almost no burning materials. Level B1: Incombustible materials: Flame-like material has good fire-retardant effect. In case of fire in the air or at high temperature, it is difficult to fire and doesn't spread quickly, and when the fire source is removed after combustion, it stops immediately. Level B2: Incombustible materials: Combustible materials have a certain flame resistance. In case of fire in the air or at high temperature, it will immediately burst into flames, and easily leads to the spread of fire, such as poles, wooden frame, wooden beams and wooden stairs,ect. Level B3 : Incombustible materials: No flame-retardant effect, hidhly flammable and high fire risk. 2, The external wall thermal insulation materials could be divided according to the fire?rating. 1) thermal insulation material that has the level A combustion performance: Spraying inorganic fiber, glass wool, foam glass, ceramic foam, rock wool, foam cement and perlite obturator, and so on. 2), The thermal insulation material that has level B1 combustion performance: Special processed extruded polystyrene board (XPS) / special processed polyurethane (PU), phenolic and polystyrene powder. 3), Thermal insulation materials that have level B2 combustion performance: Molded polystyrene board (EPS), extruded polystyrene board (XPS), polyurethane (PU) and polyethylene (PE), etc. The information given is for reference only. Hope it will help you.
- Q: What kind of fireproof material is used for steel structure?
- Brushing or spraying the coating on the surface of steel structure to prevent burning and insulate heat. It also prevents undermining the rolled steel from rapid temperature elevation and avoid collapse of building for lose of supporting capacities. Agglutination material are classified as fireproof coatings for steel structures which is solvent based and Water-based steel structure fire retardant coatings. Fireproof coatings for steel structures which is solvent based are subdivided into fireproof coatings for steel structures which is solvent based with low benzene content and fireproof coatings for steel structures which is solvent based with high benzene content (TVOC≤600g / L, benzene ≤5g / kg). It can be divided by thickness. ultra-thin (CB) fireproof coatings (coating thickness ≤3mm), thin (B) fireproof coatings (3mm & amp; lt; coating thickness ≤7mm) and thick (H) steel structure fire retardant coating (7 mm & amp; lt; coating thickness ≤45㎜). The coating can be divided into non-intumescent fire retardant coating and intumescent fire retardant coating according to the the expansion properties. Slim (CB) and fire-resistant coating for steel structure and thin(B) fireproof coatings is intumescent fire retardant coating, thick (H) fire-resistant coating for steel structure is intumescent fire retardant coating. Unprotected steel structure has fire endurance of 0.25 hours.
- Q: Which kind of furnace hearth refractory is better?
- Coal is acidic medium, so the matched material should be acidic refractories oriented, like silica?bricks. For example, the coking coke oven and carbon furnace made of carbon are in reducing atmosphere, so they use silica bricks which have low price and good high-temperature indicators. If the part has special requirements, you can then consider other refractory on request.
- Q: What's the material of electrical fire prevention board?
- Industrial electrical fire prevention board is mainly aimed at fire protection and thermal insulation. Iron plate is electrically conductive with good thermal conductivity, which will cause the result that the equipment is not insulated and suffers larger superheating surface! ! ! !
- Q: Manganese steel belongs to refractories
- NO!
- Q: Does anyone know what is a lightweight refractory material?
- Light weighted castable is one of the kind.
- Q: Is it normal for caable fire resistant material to catch on fire?
- Abnormal, preventive measures: 1 take fire preventive measures. Measures taken for fire retardant measures of cable: (1) seal closely with fire resistant materials holes ran by cables through walls, shafts to prevent the cable fire, high temperature gas diffusion and spread when cables are on fire. (2) to wrap the cable with the insulation refractory material, when the cable is surrounded with fire, warpped cable is insulated by the insulation material from fire, so it will not be burned. If the cable itself is on fire, fire will be extinguished thankes to lack of oxygen in warpped cable, to avoid the fire to spread out. 2 to strengthen the cable circuit switch and regular protective check and maintenance, to ensure that the action is reliable. 3 to strengthen the cable operation and monitoring, to avoid the overload of the cable operation. . 4 regularly clean dust on the cable, to prevent cable from catching on fire due to the accumulation of dust. 5 to ensure the construction quality, the quality the cable must be strictly in line with the requirements and standards. 6 cable laying should maintain enough distance form the heat pipe, control cable is no longer than 0.5 meters; power cable is no longer than l meters. Control cable and power cable should be divided into slots, be layered and seperated instead of being overlapped . For the parts that do not meet the requirements, measures must be taken to insulate heat and fire. 7 regularly teat cable , abnormal problem should be handled in a timely manner. 8 install fire alarm so that fire will be discovered on time, and cables will not catch on fire. 9 the cable trench should be kept dry to prevent the cable from being affected with damp, or leading to declined insulating function and short circuit.
- Q: Who knows what material is in the center of fireproof rolling curtain?
- Material and the type high silica cloth as curtain, side rails, with galvanized steel in its end and stainless steel two kinds of materials with double curtain in the end I hope my answer can help to you
Send your message to us