CABLE GLANDS-ZINC Metal Calbe Connector
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description:
1.The bolt of Metal Calbe Connector is made of brassor zinc material, beautiful outlook and high quality.
2.Compact structure, water resistant, anti-oil, anticorrosive.
3.DDJ-B Metal Cable Connectors are the fittings for cables.The joints can lock the cables tight and protectively.
Besides the following specifications, the size and thread standard can be varied at your discretion as per requirements.
Cable gland box feature:
We are providing PG types brass cable gland as one of the many cable accessories that have mostly circular or hexagonal cross sectional area and are used across different industries for various applications. Made up of high quality materials the connectors are bound to follow the industry standards. These are an ideal tool for commercial and industrial uses including transformer connectors,air conditioning and heating. Known to provide smooth connection, Waterproof Connectors have no sharp edges to strip wire. The connectors are durable and resists rough environments. Offered at the cost-effective prices.
- Q: 1000 kW 600 m cable to use much
- Such a large load so far away, can only be transported with 10KY, near the installation of the transformer Caixing, if the 380V transmission, cross-sectional area, high cost, loss of large, not worthwhile. 10KV high-pressure delivery, current 55A, with 25mm? copper cable 35mm? aluminum cable delivery on it. If the 380V transmission, according to the line voltage loss simple calculation formula △ U% = PL / CS take △ U% = 5 copper cable S = PL / CS △ U% = 1000X600 / 77X5 = / 385 = 1558mm? aluminum cable S = PL / CS = U06 / 46X5 = / 230 = 2307mm? Line voltage loss △ U Simple calculation formula △ U% = PL / CS △ U% - Percentage of voltage loss P - Active power of conveying (Kw) Distance of L- M) C-constant, aluminum single-phase 8.. aluminum three-phase four-wire 46; copper single-phase 12.. copper three-phase four-wire 77S-conductor cross section (mm?) (quoted from "electrical entrance permit test low pressure Class theory "" electrical engineering basis ")
- Q: Is the cable head made of every building?
- Generally have every building floor wiring closet must be connected to the big cable. The big cable comes in to do the cable head
- Q: What is the meaning of PG + digital markings for electrical wiring?
- If no color distinction, 100 meters after you know which line of the fire line which line? The
- Q: 3 by 16 cable is a few flat? How? That 5 by 16?
- Is the power directly out of the CPU power supply line or on this basis and added the extension line
- Q: How much of the cable with the switch?
- The switch is selected according to the current. General switch = (2-2.5) Current three-phase current = P / 1.732 / 0.38 / 0.8 Single-phase current = P / 0.22 / 0.8
- Q: Does anyone know the "line buckle" classification (including shape / size / material / has been some commonly used size!) Line deduction is a hardware products! For daily necessities!
- In accordance with the relevant safety regulations, the power cable should not be parallel to the top of the thermal pipe laying, when can not be avoided, the interval distance should not be less than 1000mm, during which should also take effective insulation measures. Power cable and thermal pipe cross, the thermal pipe insulation layer, the separation distance should be not less than 500mm, no insulation layer should not be less than 1000mm, and in the cross with the insulation board to be protected, the length of the insulation board should not be less than d + 2000mm (d for the thermal pipe insulation layer diameter).
- Q: Can the main cable be aluminum cable? And explain why, thank you!
- Reply to the landlord: I read a part of the literature, more Google is aware of the following part may be your reference weak construction specifications 1
- Q: 5 air conditioning can be used 4 square cable
- Lengthened low voltage side, the line resistance increases, the voltage drop increases. Reduced load capacity. So that the router due to insufficient supply voltage and can not work properly. It is not allowed to use 9V power supply. Voltage is too high, the router part of the internal power supply increased power, heat increased, it is possible to burn the router. It is necessary to extend the power cord, I suggest you extend the power supply side (220V one end) safe and reliable. Increase the voltage to increase the supply current, in the electrical working voltage range (with the electrical work voltage range) is allowed, too low electrical appliances can not work properly. Too high there is the risk of burning appliances, according to your actual situation, marked 5V0.2A that the router works at rated voltage, so the way to improve the supply voltage is not applicable. So you can only improve the power supply power (that is, you say to increase the power supply current rather than voltage). With the reserve power, it will provide enough current at the rated voltage (the router as a resistor, from I = U / R, you can know the danger of increasing the voltage) need help please message
- Q: The difference between nylon balls and geese and ducks
- As long as the cable is thick enough, 20 meters of the basic loss can be ignored.
- Q: How do I ask for cable prices? How many tons is one or more?
- Yellow line is video, red and white are audio, you can only pick one!
Send your message to us
CABLE GLANDS-ZINC Metal Calbe Connector
- Loading Port:
- Ningbo
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 pc
- Supply Capability:
- 300000 pc/month