CECOX 25.6V 50Ah Lead Acid Battery Replaced by Lithium battery(JX)

CECOX 25.6V 50Ah Lead Acid Battery Replaced by Lithium battery(JX)

Ref Price:
get latest price
Loading Port:
Stock in Panama
Payment Terms:
TT OR LC
Min Order Qty:
50 pc
Supply Capability:
5000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specification

Product Model:
JLS-2450FP
Nominla Energy@25℃:
1280WH
Nominal Capacity@25℃:
50AH
Nominal Voltage:
25.6V

Specification


Product ModelJLS-2450FPJLS-24100FPJLS-24120FP
Nominal Voltage25.6V
Nominal Capacity@25℃50AH
100AH120AH
Nominla Energy@25℃1280WH2560WH3072WH
Battery CellPrismatic 50Ah
Prismatic 100AhPrismatic 120Ah
Configuration8S1P8S1P8S2P
Max Continous Charge Current@25℃50A100A100A
Max Continous Discharge Current@25℃50A100A100A
DC Resistance≤10mΩ
Full Charged Voltage29.2V
Discharge Cut-off Voltage20V
Operate Temperature RangeCharge:0℃~55°℃Discharge:-20℃-60°℃Storage:-20°C~45°℃
Dimension (mm)326*171*215mm326*171*215mm522*240*218mm
Weight (KG)12.5KG25KG28KG
Terminal TypeScrew terminal
Cover Sealing typeScrew/ gel sealing optional
WaterproofIP65
Cycle life

100% DOD Cycles @25C, IC/IC:>2000 times

80% DOD Cycles @25℃,1C/1C:>3000 times

50% DOD Cycles @25℃,1C/1C:>5000 times

LCD Screen DisplayOptional(Heating function for application in cold area)
BluetoothOptional (Bluetooth with mobile APP)
Series and Parallel FunctionAvailable to make in series and parallels to get 48V
Heating FunctionOptional(Heating function for application in cold area)


Sales area

Cooperation brands

Certificates

Our company

Product Application

FAQ

Q1: Are you a trading company?
A1: Yes, we are a professional trading company that can help customers find the most suitable products and provide the most suitable solutions.

Q2: What's your product range?
A2: We can provide you with mainstream and reliable products in the market, including lithium batteries, photovoltaic modules, inverters, etc


Q3: Why choose us?
A3: Reliable-- Our certifications like ISO , TUV is our commitment to quality and safety for our lithium batteries.
     Flexible--We can integrate market resources for you and provide you with the most suitable purchasing plan.

Q4: Are these products guaranteed
A4: Yes, they have 12-years product warranty and 25-years performance warranty.

 

Q5:Can your company provide samples?

A5:Yes, our company can provide samples for you.


Q:What is the difference between a maintenance-free battery and a conventional battery?
Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
Q:What are the technical parameters of the battery?
The main performance parameters of the battery are the following: model; voltage; battery capacity; battery type, such as lead-acid batteries, alkaline batteries, lithium batteries, solar cells, fuel cells.
Q:How to determine the battery is good or bad?
Instrument test: the general use of battery discharge tester, the test instrument two positive and negative clamp were holding the battery positive and negative electrodes, press the test button to observe the test instrument instructions.
Q:What battery does the van use?
The battery is mainly composed of tube positive plate, negative plate, electrolyte, separator, battery compartment, battery cover, pole, injection liquid cover and so on. The electrode of the exhaust type battery is made of lead and lead oxide, and the electrolyte is an aqueous solution of sulfuric acid. The main advantage is the voltage stability, the price is cheap; the disadvantage is lower than the energy (that is, per kilogram of battery storage power), short life and routine maintenance frequently. Old ordinary battery life of about 2 years, and the need to regularly check the height of the electrolyte and add distilled water. However, with the development of science and technology, lead-acid battery life becomes longer and maintenance is also more simple.
Q:How does battery activation work?
If the battery is charged, because the battery discharge itself, the active substance to activate, not add acid, but should be added pure water (no minerals and impurities in the water) is best steaming water, and now you Since the addition, you can use water to wash several times, and then use 1C current charge to 2.3 times. Then discharge, so repeated several times, will be better. So that you can remove the vulcanization.
Q:How to repair the battery?
Connect the positive and negative output of the repair instrument to the positive and negative pole of the battery, open the repair instrument, repair the battery. The first repair time should be no less than 48 hours.
Q:What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q:How should the battery be well maintained?
So the proposed owners if the vehicle long-term stop, but also 2 to 3 months for the battery for a charge.
Q:How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords