CE certificated Industrial Fire Proof Door
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 50 pc
- Supply Capability:
- 3000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Sectional Industrial Doors Techncal Data
Door description | Technical data | |
Door Panels | Panel Style | Finger protection 40mm thickness & non finger protection 40mm/50mm thickness door panels |
Panel Construction and thickness | Steel+PU foam+Steel, 40mm/50mm thickness | |
Panel Color | White, silver gray,dark gray | |
Panel Surface Style | Flat stucco, Flat woodgrain/ Line stucco, Line woodgrain/ Square stucco,Square woodgrain/ Micrograin | |
Panel Steel thickness | 0.326mm/0.35mm/0.4mm/0.5mm, Panel Steel PE Paint thickness is 25um | |
Door Hardwares | Tracks style and thickness | 2" &3" tracks, 2.0mm thickness |
Track cover(2.5mm thickness) | Injury of the finger caused by the movements of rollers in vertical tracks will be effectively prevented by the track cover. It will seal the space between the wall and the vertical tracks so the finger can not be inserted in. | |
Track and track cover,Hinges,brackets surface finish | Bright Zinc Galvanized | |
Hinges/roller brackets & Bearing brackets thickness | 2.5mm | |
Steel Rollers | 2"*4, 2"*7, 3"*4, 3"*7 steel rollers | |
Top/bottom weather seals | Aluminum stretches, and EPDM rubber seals | |
Safety system | Spring break safety brackets | If spring broke , the spring break safe device will stop the door's falling to protect the people, kids or other things who is passing the door |
Cable break safety system | If cable break, the system will stuck on tracks then prevent the door from droping. | |
Air safety bottom | the door will rebounce back if it meet obstacle during closing. | |
Door Motor | Motor style | Axle industrial motor |
Manual chain | open or close the door if power off manually | |
Motor Voltage | 380V or 220V | |
Motor remote controls | 2 or more | |
Motor sensor (Optional) | available |
2.Sectional Industrial doors Lift styles
Vertical Lift: if door opening Height H>= Door headroom distance h, then choose vertical lift
High Lift: Door headroom distance h>1m, but h<H door opening height
Standard lift: Door headroom distance h<1m< span="">
3.Sectional Industrial doors Hardwares
Safety System:
(1) Cable Break Safety Brackets: This bracket will hold the track and prevent the door from dropping immedirectly if the cable broke.
(2) Spring Break Safety Brackets: The bracket will hold the solid shaft and prevent the door droping if spring broke.
(3) Safety Edge: If the door meets obstacle druing its closing, the door will stop and go up directly, then protect the people or material from damage.
- Q:Really understand the friend said, anti-theft door lock how to choose the safety level
- The security level is divided into ABC currently c class for the security level
- Q:Such as title
- Detailed look at their own online indicators, I understand that the three out will not give people flicker. Check the anti-theft door to see three indicators. 1. Brand: Pan Pan Wang Li Mei heart step yang scolding money to rescue the ship to find the class 2. anti-theft door level: A B Bing Ding, Class A best. Formal level mark hit the door in the door on the door, it is best to have qualified code (hit the door is false), the level describes the security door, the thickness of the door frame steel. 3. Door lock level: A / B / super B. Super B best. Personally think that the ultra-B-level lock is a must, B-level lock of the national standard anti-technical open (lock tamper of the key indicators) for 5 minutes, ultra B anti-technical open time for 180 minutes. Like the difference between Audi and Alto. Personal recommended Wang Li, the only door made and lock the business, the door is of good quality. All doors are super B locks. The strength of the crystal can see Pan Pan Jing (Pan hope for the B-lock, to recognize), Jingjing also for the super B-class, is the price is too high, the door is still very good.
- Q:Our factory is doing non-standard door, I am an apprentice, the master refused to teach me, ask how to debug, is the facade about a little stuck around how the door is the ordinary hinge, said that the toilet The more detailed the better the better, my points all to you, in this grateful not more
- Your master slam the door is to adjust the diagonal, mainly to see whether the door around the door after the door evenly. Facade the door can be used to adjust the diagonal or the hinge out to solve.
- Q:Class A anti-theft fire door standard is what
- Anti-theft and fire doors are different, there is no Class A anti-theft fire doors, it should be discussed separately. 1. Class A security door: is the anti-damage time is greater than or equal to 30 minutes of the door. Specific values are as follows: 2. Class A fire doors refer to doors with a fire resistance of 1.50 to 2.00 h. Specific values are as follows: A fire door fire resistance limit of 1.50 ~ 2.00h; B fire doors for the 0.50 ~ 1.50h. According to the design of fire safety standards, fire doors as a, B, C three, and its minimum fire limit made the provisions, that is, Class A 1.20h, B 0.90h, C 0.60h.
- Q:What is the standard for acceptance of security doors?
- To see which level of security door, different grades have different standards
- Q:Try not to hurt the door to the best, which professionals told me how to change? More
- Please use a hot towel, attached to the above, a minute later, try! Hope to help you;
- Q:I bought the house contract is to install the anti-theft door but the developer is the installation of the fire door also said that the fire door than the anti-theft door Guichi is not really fire door The More
- Fire doors and security doors are not the same function, fire doors are special doors. Family homes are generally not required to use fire doors.
- Q:How to know the size of home security door locks
- Home security door standard size is 2050 * 960, the most standard is 2050 * 860, there is the 1970 ** 860, security doors are generally based on the actual needs of the family to do, the maximum can be done 2500 * 2500. The security door is called "security door". It combines both anti-theft and safe performance. In accordance with the "anti-theft security door general technical conditions" provides that qualified security door in 15 minutes using chisels, screwdrivers, crowbars and other ordinary hand tools and hand drill and other portable power tools can not pry open or in the door to open a 615 square millimeters Open, or open a 38 mm square opening in the semicircle with a locking point of 150 square millimeters. And anti-theft door on the use of the lock must be detected by the Ministry of Public Security testing with anti-drilling function of the anti-theft door dedicated lock. Anti-theft doors can be made of different materials, but only to achieve the standard test qualified, to receive security products to ensure that the door can be called security door.
- Q:Some people say that it is necessary to adjust the hinge, is it necessary to adjust the four small Fuling Dian Gu ordered the thumping, or to adjust that big, what tools to adjust it more
- It is recommended to use the liquid lubricant on the hinge to do the door to open the door when the action door feel what kind of vibration is the hinge ring with the syringe on the hinge axis can be made on the edge of the valley,
- Q:What is the standard size of the security door?
- Under normal circumstances, when the width of the door is greater than the ordinary single door width 800-1000mm, and less than the total width of the double door 2000-4000mm, you can consider the use of child doors. So in the door between the opening and closing, do not have to drive too much of the door, in the need to carry furniture and other large objects, it can be well passed. ? Standard door size: 2100MM (height) × 1200MM (width) × 40MM (thick) ? anti-theft door single door size: 950MM (total width) × 2050MM (total height) × 110MM (frame thickness) ? anti-theft door door Size: 1200MM (total width) × 2050MM (total height) × 110MM (frame thickness) ? The widest door size: 2180MM (high) × 1320MM (width) × 110MM (thick)
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
CE certificated Industrial Fire Proof Door
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 50 pc
- Supply Capability:
- 3000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches