ANSHI 24 Ports Cat5e Unshielded Patch Panel With Cable Management
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 20 Pieces pc
- Supply Capability:
- 1000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Full Technical Specifications
1) Toolless and cabinet designed
2) Label and inlaid marks for convenience of identification and network management
2) Highly resistance and inflaming retarding material, Grade UL94-0
3) Connection strap to adopt gold plate,alloy of Cu and Be,IDC to use the alloy of Cu and P
4) Firm and easy installation reducing the installation and operation cost.
5) Transmission stability.
6) Module part is fitted with shield, protecting inner 1DC contact from irregular working in rugged environment
7) Meet or exceed the current T568A and T568B standard
Mechanical property
Times of repetitive use:≥800
Termipoint life:≥200
Insulation diameter:0.7mm-1.4mm(1.6mm)
Temperature interval:-40°C-70°C(storing) / -10°C-60°C(installation) /-10°C-60°C(working)
Application standard:
ISO/IEC11801:2002
IEC 60603-7-4(edition:1.02003-01-10)
IEC 60603-7-2(edition:1.02003-01-10)
EIA/TIA568B.2-1(2002de-embedded)
1 With Cat5e keystone modules used for 19"cabinet , Adopt special IDC, suitable for use 110 type impact tools,180 wire termination , modularization design , Adopt special cable manager.
2 IDC: phosphor bronze and silver plating (20-50uinch), suitable diameter 0.4-0.6mm, durability 200 cycles
3 Contact pin: phosphor bronze and gold plating (20-50uinch), mating durability not less than 750 cycles
4 Anti-burn performance: plastic part made from PPO and PC and ABS, meeting the international standard
5 Intermediate resistance: no more than 2.5m ohm in normal atmosphere pressure (not including bulk resistor)
6 Insulated resistance: no less than 1,000M ohm in normal atmosphere pressure
7 The intensity of anti-currency: DC 1,000V (AC,700V) No puncture and flash-over phenomenon in one minute. Accord with industry standard
8 Label: clear label to ensure easy to manage
9 Type: unshielded ,24 ports.
10 Standard: designed by international ISO/IEC11801 and TIA/EIA568
- Q: What are the twisted-pair cable connection devices? How are these connected devices connected to a twisted pair cable to form a complete communication link?
- Speed ??reasons for several reasons: First, the network itself, you want to connect the target site where the server bandwidth is insufficient or the load is too large
- Q: In the integrated wiring system, the use of the 110 patch panels, fiber patch panels, RJ45 patch panels are different between what? How to use it?
- Ah, according to "JGJ / T16-2008 civil building electrical design specifications" Table 21.9.1-1 integrated wiring cable and power cable spacing, parallel with the twisted pair cable laying the same route 10kVA 380V power cable, two Minimum spacing between cables: . such as parallel laying: 600mm. one side of the metal wireway or steel pipe: 300mm. both sides of the metal wireway or pipe: 150mm
- Q: AMP ultra-five 24-port patch panel use, including cable, card line and a series
- . line pipe bar spacing no specific specification requirements, but generally not more than 1.5 meters, bend, casing joints to be encrypted bandage. . riser reservations as if the local construction process is different, are generally reserved for the first hole, the temporary installation of the riser. . riser tube casing to be higher than the upper side of the steel mesh about 100mm.
- Q: Who can give me a detailed quotation? Want some point threading distance is not the same, so how the price positioning? More
- You are completely correct, you can choose a variety of connection methods, graphics quality from good to bad followed by VGA (D-SUB), color (component), S terminal, video.
- Q: 110 patch panel with the network patch panel What is the difference
- YC for heavy duty rubber cable for AC 500 V and below Outdoor mobile electrical equipment, 3 * 25 + 1 * 10 for three 25 mm square and 10 mm square with ground wire consisting of four core heavy duty rubber cable The YC3 * 35 + 1 * 16 represents three 35 mm square and one 16 mm square four-core heavy duty rubber cable with ground wire. There are a lot of specifications for this kind of rubber sheathed cable
- Q: What is the role of what they and switch wiring cable? If the 500 line switches, how to match between better? More
- Cable head system security with "indoor dry packet power cable head system security" of the quota, but also to convert the coefficient, the same coefficient in the chapter inside (a cable has two cable head)
- Q: What is the DDF rack? what's the effect?
- Hello: "Wires" and "cable" in the concept and there is no strict distinction between the boundaries, although the narrow sense of "wire" and "cable", said broadly should be collectively referred to as "cable" The Generally known as a single called "line", more than called "cable"; small diameter called "line", the structure of complex multi-called "cable"
- Q: A router three switches three network patch panel a telephone patch panel seven cable management cabinet 1.2 meters how to wear a good cabinet 60 network cable network together
- This is because your system is updated to . saying 7 for the data line charger requirements become higher, you can buy a relatively more professional data lines, of course, no problem, the product I also recommend, quality Did not say
- Q: Pure fiber home, and five lines of households, from the Bureau of light equipment to the district patch panel from the distribution frame in the home, the middle of the equipment with this equipment? Why use it, why not? Try to answer detailed requests for reference. More
- There is a voltage amplifier, there is a current amplifier! But this can not be called a power amplifier! According to the energy defensive rate that there is no power amplifier! In the power of a certain premise, the power supply current and voltage is inversely proportional! You can sacrifice current To increase the voltage! In turn, can also reduce the voltage and in exchange for high current!
- Q: 30 on the large number of cable how to fight on the 110 patch panel, how to order, please inform, thank you, which
- Check the following aspects: 1.FANUCOI-PD system parameters .. is the axis of the positive, negative, soft limit. Check if the setting is appropriate, so that its travel range to meet the work trip. 2. Hardware trip switch: trip switch collision block: the installation location is appropriate, whether loose, whether there is iron. Trip switch: whether the corrosion, whether the switch inside the wiring is bad, the roller is not pressed after the fall, check it. If the travel switch is moved together with the machine, it is possible that the line of the trip switch in the hose is moved to a disconnection and moved to another place.
1. Manufacturer Overview
Location | Zhejiang, China |
Year Established | 2001 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO 9001-2000;SGS;UL;TUV |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shanghai,Ningbo |
Export Percentage | 31% - 40% |
No.of Employees in Trade Department | 1-2 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | Below 1,000 square meters |
No. of Production Lines | 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | High and/or Average |
Send your message to us
ANSHI 24 Ports Cat5e Unshielded Patch Panel With Cable Management
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 20 Pieces pc
- Supply Capability:
- 1000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches