ANSHI 24 Ports Cat5e Unshielded Patch Panel With Cable Management
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 20 Pieces pc
- Supply Capability:
- 1000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Full Technical Specifications
1) Toolless and cabinet designed
2) Label and inlaid marks for convenience of identification and network management
2) Highly resistance and inflaming retarding material, Grade UL94-0
3) Connection strap to adopt gold plate,alloy of Cu and Be,IDC to use the alloy of Cu and P
4) Firm and easy installation reducing the installation and operation cost.
5) Transmission stability.
6) Module part is fitted with shield, protecting inner 1DC contact from irregular working in rugged environment
7) Meet or exceed the current T568A and T568B standard
Mechanical property
Times of repetitive use:≥800
Termipoint life:≥200
Insulation diameter:0.7mm-1.4mm(1.6mm)
Temperature interval:-40°C-70°C(storing) / -10°C-60°C(installation) /-10°C-60°C(working)
Application standard:
ISO/IEC11801:2002
IEC 60603-7-4(edition:1.02003-01-10)
IEC 60603-7-2(edition:1.02003-01-10)
EIA/TIA568B.2-1(2002de-embedded)
1 With Cat5e keystone modules used for 19"cabinet , Adopt special IDC, suitable for use 110 type impact tools,180 wire termination , modularization design , Adopt special cable manager.
2 IDC: phosphor bronze and silver plating (20-50uinch), suitable diameter 0.4-0.6mm, durability 200 cycles
3 Contact pin: phosphor bronze and gold plating (20-50uinch), mating durability not less than 750 cycles
4 Anti-burn performance: plastic part made from PPO and PC and ABS, meeting the international standard
5 Intermediate resistance: no more than 2.5m ohm in normal atmosphere pressure (not including bulk resistor)
6 Insulated resistance: no less than 1,000M ohm in normal atmosphere pressure
7 The intensity of anti-currency: DC 1,000V (AC,700V) No puncture and flash-over phenomenon in one minute. Accord with industry standard
8 Label: clear label to ensure easy to manage
9 Type: unshielded ,24 ports.
10 Standard: designed by international ISO/IEC11801 and TIA/EIA568
- Q: Is the POE switch connected to the network camera via the patch panel to affect the power supply function?
- Will affect the speed, but will not burn potentiometer. If the conditions can be limited, only the power and control with the laying of the control signal cable can wear steel pipe wiring, steel pipe to do a good grounding, the control line with shielded wire, so you can reduce the interference to achieve precise control and data display.
- Q: Please complete the system that, from the beginning of the Group to buy a telephone exchange to how to make a telephone line, how to connect patch panels, install all the extension and the normal extension of each other and playing outside, to make people can learn to manage the company group phone , Answering a good score is not a problem more
- All the premeditated In addition to the flower wall to occupy the advantages of the backdrop I am close to the pose, my hand quietly on the knee, a finger lift, usually often on the camera - a posture before the speech, in the first word Before I made this photo I made no pity to pose, there are
- Q: What are the twisted-pair cable connection devices? How are these connected devices connected to a twisted pair cable to form a complete communication link?
- Is there a cable with 3 * 10 + 2 * 6? Should it be 5 * 10? Generally 1.5 times
- Q: What is the minimum length of the jumper between the patch panel and the Category 5 cable or the Category 5 cable in the integrated wiring project? Is there a specific requirement in the engineering specification?
- Insulated wire cross-section selection calculator] is characterized by cross-section, current, load real-time calculation, is the engineering construction, interior decoration wiring, household electricity and other insulated wire selection of the preferred tool, the use of very convenient.
- Q: Why do you say if there is no patch panel, front-end information points directly connected to the switch, then if the cable once the problem, it is facing to re-wiring. In addition, the management is also more chaotic, multiple plug may cause the switch port damage. The existence of patch panels to solve this problem, you can replace the jumper to achieve better management. How he is managed by jumper to achieve more
- According to the work area of the socket port number to the horizontal cable label, to the patch panel port number, to ensure that these three parts of the same number, and then do the form, marked above: terminal equipment number (ID / IP) address, network The number of the information outlet, the cable number, the patch panel port number, the exchange equipment port number; again with the plan, the system map is accurate, to ensure accurate, so that the completion of the integrated wiring system of the initial management information. ---- focus is the number can not be wrong.
- Q: AMP ultra-five 24-port patch panel use, including cable, card line and a series
- This is not a problem with voltage instability. This is your power cord material does not work, your graphics card over current is very large, resulting in yellow line 12V over current, and the wire will lead to poor impedance will gradually become larger heat, over time will burn the power cord. It is recommended to replace a power cord with a good material.
- Q: Integrated wiring, voice information points in each floor into the patch panel, or cable convergence in a layer of the total control room and then on the distribution frame?
- That is called 3.5 to double lotus transfer cable or adapter, X treasure has to sell, usually within 10 dollars
- Q: Explain the voice of the large number of cable households after the specific order of the connection equipment, more
- Cable laying, you have to find a book in this regard to see
- Q: What is the DDF rack? what's the effect?
- However, with the modernization of power transmission equipment and information needs of social development, and now the wires and cables have been developed to the "cable in the cable", "cable in the cable" era
- Q: Integrated wiring material budget, fiber pigtail, how to calculate?
- 1: the installation is very simple, line problems can be explained that 2: all have 3: buzz are generally hard disk and CPU heat sink problems, the hardware is very simple software needs to partition, install the system
1. Manufacturer Overview
Location | Zhejiang, China |
Year Established | 2001 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO 9001-2000;SGS;UL;TUV |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shanghai,Ningbo |
Export Percentage | 31% - 40% |
No.of Employees in Trade Department | 1-2 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | Below 1,000 square meters |
No. of Production Lines | 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | High and/or Average |
Send your message to us
ANSHI 24 Ports Cat5e Unshielded Patch Panel With Cable Management
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 20 Pieces pc
- Supply Capability:
- 1000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches