• ACCC Dublin System 1
ACCC Dublin

ACCC Dublin

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

ProductIntroduction

Carbonfiber composite core conductors(hereafter called CFCC for short) consists of composite core and annealedaluminum formed wires  outer layer. Theannealed aluminum formed wiresouter layer and its adjacent layer aretrapezoidal cross-section. CFCC is a kind of carbon fiber product with highperformance. Compared with the traditional aluminum conductorssteels-reinforced(hereafter called ACSR for short), it has series of advantagesincluding light weight, high tensile strength, high heat resistance, corrosionresistance, high current carrying capacity etc.

Inthe case of the same weight, CFCC has higher current carrying capacity, whichwill be twice of the conventional ACSR. The annealed aluminum formed wireswhich has less line loss is used in CFCC. Moreover, Composite core isnon-magnetic material, so it does not have magnetic loss and thermal effectscaused by the steel wire material. It will greatly reduce the line transmissionloss. CFCC can improve the current carrying capacity under high temperaturesince its heat resistance (can be 160 aslong-term running temperature) is far more higher than that of the ACSR (70 as themax operating temperature). On the other hand, CFCC has light weight. So in thecase of the same weight, cross-section of aluminum can be increase by 20%-40%.Therefore Reerecting the new CFCC line for increasing transmissioncapacitywithout transforming the poles and towers became possible.

CFCChas the higher strength and higher level of safety. The tensile strength of theACSR is 1240MPa, and high strength steel conductors is 1410MPa; however CFCCcan be up to 2400MPa which increases the safety.

Itwill reduce the transmission line corridor, save land resources and lower thecomprehensive total cost of transmission line construction by using CFCC. CFCC’s linear expansion coefficient is small, and it reduces the lines sag, andwill not be affected by long-term creep of aluminum, also it avoids sag due tothe thermal expansion of the traditional ACSR. The height of the tower can bereduced, and the distance between towers can be increased due to its lightweight. More than 16% poles and towers will be reduced to save the transmissionspace height and areas.

CFCChas good anti-aging performance and long operating life. it avoids the troublethat the ACSR’  electrochemical corrosionbetween the aluminum and galvanized steel core. compared with the ACSR, CFCCresist acid rain corrosion.

CFCChas good resistance to wind load .with its high strength, light weight, crosssection covered by aluminum formed wire, small diameter.

CFCChave the ability of melting snow and ice. The outer layer has no gaps and iscompacted smoothly. Snow and ice is not easy to be freezed. The conductor willmelt snow and ice by itself When it is running under high temperature also.

CFCChas high current carrying capacity to reducing electricity generationcost and saving energy. It will reduce the line loss by 28% in the case of sametransmission capacity.

CFCCrepresent the technical development tide of overhead conductors. It has obviouseconomic and social benefits. it conduce to building safe,environmentally-friendly, efficient electricity grid.


Q: Four lines only reached a phase line, at the other end all charged, I use the digital pen! In addition, I often check the cable when the cable current through the dot digital pen voltage symbols sometimes have time to disappear, in other bare wires when the test keys are normal! What is this going on! Ask the heroes to give the younger brother a complete point of the answer! More
This is too difficult to give you a way to just try: with a fine wire rope, that is, lift the clothes on the stick so thick, the end of a bend, with a tape wrapped around the head, try can not wear, wear When the possibility of rotating wire rope, if you can go through the success of the half, the key is to use the wire through the more difficult, can only use the cord, hard-line 100% make life difficult.
Q: Ipad not charge how the matter. Said the cable or accessories have not been certified, and may not be able to cooperate with this ipad reliable work....
Several sets of cables in the same height of the laying, the adjacent cable between the bridge should be considered maintenance, maintenance needs, generally not less than 0.6m. This is just a matter of theory, it does not matter. Anyway, the actual construction is to do so,
Q: IPadmini. The latest version 7.1.1 up in the morning to see the non-stop display this cable is not certified does not support this feature. The The Charger original. Not on the computer charge. The Ask God to answer more
The problem lies in the charger between the machine, IPAD charging is to a charging protocol to complete, when the IPAD did not receive the agreement signal will be prompted: do not support this accessory, Apple's products have charging protocol, charging Is through the data line in the two lines and IPAD transmission charging protocol signal when ipad received the charging protocol signal after the machine internal charging circuit began to open the internal charging circuit to charge, the problem is to accept the charge signal is not so prompted not to Support, change the line to try
Q: Remove the computer and wash it off. What the motherboard did not move it, that is, the dust of those dust sasses, as well as the other wire of the skin what Sassafras wash, but the computer re-connected to the Internet when the old mistakes . and the lower right corner of the red Fork appears, disappeared after the emergence. The The Said the network cable is not plugged in, but the MODERN that POWER, LINK, LINE, 3 lights are normal display. The The This is how the matter, and just also appeared keyboard and mouse just start the machine can also be used normally, but in a moment to fall, and then plug their plug re-plug the mouse lights can be displayed, but the lights on the keyboard simply do not Bright, restart the computer but good, what is going on? bother. The The I hope the master quickly to help me, and this machine is relatively old ah No problem added: on a machine, just tried to re-create a connection in the network neighborhood, useless more
No need. Galvanized flat iron to do when the grounding grid is not anti-corrosion, but if there is welding or damaged place to become anti-corrosion.
Q: How to determine how much wire and cable should be used, the current load and how the corresponding wire, such as 4BV, under what circumstances, YJV240 what circumstances, the load is much more
Can not be removed, and so on after the first line of fluoride, and then demolition of air conditioning.
Q: Wire and cable CCC product consistency is what
PVC line, the market is better with plastic, plastic, . Wantong, etc., if only home improvement, then the brand requirements do not need so high. Small brands are the same, we see the quality. Network cable, then preferred Ann or TCL.
Q: Apple 6 Charging Why always show this cable has not yet been certified
Cable and cable distinction In fact, "wire" and "cable" and there is no strict boundaries
Q: Why this cable has not yet been certified
The manufacture of wire and cable is completely different from that of most electromechanical products
Q: What is the difference between the WDZ wire and cable, the ZR wire cable and the NH wire and cable, and what kind of wire and cable should be used?
Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria.............................................
Q: If you want to sell wire and cable, then what to do in advance to detect? The The The The The
Line width, and can not pass the gap between the chip pins, even after, but also because the distance between the wire and the lead is less than the electrical rules specified in the safe distance. In general, the ground can not pass through the gap between the chip pins, go outside or take the gap between the two columns through the gap. The width of the ground wire can also be set appropriately, and the wire is widened by adding a polygon brass cut. The safety distance in the electrical rules defaults to 10 mils, which is relatively small, and the safety distance of the different networks should be set separately as needed.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches