1. Application
This machine is mainly used for standing 7 stands steel wire, aluminum wire and copper wire.
It can be used for stranding less than 7 strands control cable.
2 Main Parameter.
2.1 Monofilament diameter: copper : 1.3-5MM
Aluminum: 1.7-5MM
Steel: 1.0-5MM
2.2 diameter after stranding: 3-15MM
2.3 host rotary speed: 500RPM
2.4 capstan diameter: PN 1500 Double wheel
2.5 output speed: 17-165M/min
2.6 pitch of stranding: 34-330MM
2.7 pay-off bobbin size of the out-host one: 500MM
2.8 pay-off bobbin size of the host: 500 MM
2.9 take-up bobbin size: 800-1600MM
2.10 main motor power: 30KW (AC)
3 Constitute:
3.1 pay-off device PN 500: 1set
3.2 lead frame: 1set
3.3 6 bobbins host 1set
3.4 Main drive mechanism 1 set
3.5 die cast holder: 1 set
3.6 Mechanical meter counter: 1 set
3.7 1500 double wheel capstan: 1 set
3.8 1600 No-spool type take up and wire arranging device: 1set
3.9 electric controlling system: 1 set
3.10 protection fence: 1 set
- Q: Which has, know the power of the electrical, choose the cable formulas. And explain it
- No, but you can buy a TV box, plug in the line computer will be able to watch TV
- Q: Welding machine grounding in the steel platform, may be bad contact, welders in the operation, why will the ground burned out of the cabinet in the electric control cabinet more
- I was doing the construction, I encountered in the large steel structure plant, the bridge is generally walking along the crane beam, with the angle and the channel to do another bracket, no crane beams are generally along the pillars, so that the bridge Layout is better looking, but also facilitate the construction. Column of the bridge is also the use of angle and the like to do the bracket, this depends on the requirements of the bridge itself, as in the wall bridge, in fact, encountered a pillar but also turn, although it seems space utilization is big, but in fact To the construction of the inconvenience caused by a lot. Walking along the roof frame I have not encountered before. Can not give you any advice. I only from the construction point of view to consider this issue, not to mention design experience.
- Q: Emergency cable T-box and cable distribution box of the information?
- Generally only need to use three-in-one cable (ie AV composite video cable) to EVD machine and TV can be connected up; Method is as follows: . the first AV cable into the EVD machine AV output interface; the other end of the insert . start the EVD machine and TV; . use the TV remote control operation, press the signal source key to switch the TV signal source to AV Mode, you can display the EVD machine start screen, indicating that the EVD machine and the TV has been successfully connected; . then you can use the EVD player to play the disc, the film screen and sound will be transmitted to the TV to play out.
- Q: Three-phase five-wire system of the national standard cable 5 * 2..5 * .5 * .5 * .5 * .4 * 25 + 1 * 16 seizure light libel gambling Chi Chi performance, 4 * 35 + 1 * .4 * 50 + 1 * . the cable can bring much power equipment? The The Equipment for the United States more air-conditioning units
- 2.5 can bring 5.5KW4 square can take 7.5KW6 square can bring 12KW10 square can bring 15KW16 square with 22KW25 square can bring 37KW35 square can bring 55KW50 square can bring 75KW or more cable refers to the copper wire does not include aluminum, the load refers to the Is a three-phase 380V device.
- Q: What recycled rubber is suitable for the production of wire and cable?
- Under normal circumstances, the use of different cable bridge as far as possible apart, like your situation, if the power cable with the BV line are more, it is recommended to do separately, if one of the few, you can lay along the bridge piercing. Two cables on the same bridge is the last consideration of the program, but also separated by a partition, otherwise it will cause the construction and post-maintenance of the great inconvenience.
- Q: How do I install the wire according to the load selection of the cross-section of the wire? China's market which have the specifications of the wire (cross-sectional size) Thank you
- Nylon cable ties. Often used to bundle wires, oil and gas pipelines. Factories, construction sites, buildings, the most applications.
- Q: My three friends steal communications cable 3 times, the results were caught by the police, they will be subject to social punishment? Three people have a 17-year-old (will be sentenced to a few years), a total profit amount may be more than .000 yuan. More
- Will be sued for the crime of sabotage of public telecommunications facilities, because the amount of profits amounted to .000 yuan, so the actual value of the cable should be higher than that, resulting in greater losses, the amount is huge or the amount is particularly large, so at least Sentenced to more than three years of imprisonment, minor is only a statutory light punishment of the plot, but not the statutory mitigation of the plot, so I suggest you go to the local lawyer to help defend the defense.
- Q: Before the company is a small line-based, now want to 35KV below the cable production line, the general production line to a number of workers, how many machines?
- WDZ: W halogen-free, D low smoke, Z flame retardant, halogen-free low smoke flame retardant cable is now the use of trends especially in the staff concentration, the building widely used ZR: flame retardant cable used in the case of flame retardant requirements, NH: Refractory means that such cables have the ability to guarantee 1 hour in the flame burning, there are refractory requirements occasions,
- Q: Production enterprises, workshop machines with more than ten thousand cable, should be credited to what subjects, or the cost of this machine together with the fixed assets into the machine.
- Lighting never use a line, the circuit to form a loop at least two lines. The lamp does not have the grounding terminal protection, do not need to protect the ground when the line, with two lines; grounding terminal protection need to be grounded when the need for three lines; lamps own battery as emergency lighting, there is a battery without interruption Charge line, which requires four lines. The current lamps are required to bring the ground terminal, connected to the ground, so at least three lines.
1. Manufacturer Overview
Location | Hebei,China |
Year Established | 1996 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe Northern Europe Southern Europe |
Company Certifications | ISO 9001:2008 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Tianjin,Shanghai |
Export Percentage | 31% - 40% |
No.of Employees in Trade Department | |
Language Spoken: | English, Chinese, Russian |
b) Factory Information | |
Factory Size: | 10,000-30,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Average |
Send your message to us
Tubular Stranding Machine 1+6/500
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Set set
- Supply Capability:
- 6 Sets per Month set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords