T8 Led Lamp 1200Mm 15W 18W 22W 25W 3000-7000K 80Lm/W 50000H
- Loading Port:
- Ningbo
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 100000 Pieces pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Type | Power | Lumens | Base | L x W x H (mm) | C.C.T | Voltage | Life | Angle of Light | Applicable temperature |
T8A1200-G13 | 15W | 1520LM | G13 | 1212x 26 x 26 | 2700K-6500K | AC85-265V | 50000 | 140° | -40°C-65°C |
18W | 1680LM | G13 | 1212x 26 x 26 | 2700K-6500K | AC85-265V | 50000 | 140° | -40°C-65°C | |
22W | 2200LM | G13 | 1212x 26 x 26 | 2700K-6500K | AC85-265V | 50000 | 140° | -40°C-65°C | |
25W | 2650LM | G13 | 1212x 26 x 26 | 2700K-6500K | AC85-265V | 50000 | 140° | -40°C-65°C |
LED Tube Light Applications:
Widely applied in hotel , meeting room , offices , hospitals , schools , factories ,
shopping malls , supermarkets , kitchen, home indoor lighting and so on
Delivery:
Shipping Service | Estimated Delivery Time |
DHL | 2-8 business days |
FedEx | 3-8 business days |
TNT | 2-10 business days |
UPS | 1-7 business days |
EMS | 6-14 business days |
ePacket | 7-12 business days |
China Post Air Mail | 7-15 business days |
China Post SAL | 14-30 business days |
Air freight | 3-10 business days |
By Sea | 30-40 business days |
1. 3-5 business days for Sample Orders; 7-30 business days for Bulk Orders for Bulk Orders.
2. "Business days" means Monday-Friday, excluding holidays.
3. DHL and UPS cannot ship to military or P.O. boxes address
4. The Shipping Service above is for reference only, for any other questions, please feel free to contact us.
Factory:
- Q: Fluorescent lamp double lamp tube wiring method
- Leds that do not normally require special orders are mostly built with built-in power, which is directly available. Most can only need to remove the starter on the traditional stent line (is a cylinder bracket highlighted below) mount tubes can be used, if not yet so could you use the stent is a relatively new "electronic" will be a little trouble need you open the stents to get inside the ballast also take off to the inside of the line directly connected to the utility, LED bulb is directly at the mains. Of course, if you understand the circuit and you're not afraid of trouble, it's advisable to remove the "regenerator", because the "ballast" is a power drain.
- Q: The reason for the slow start of an old-fashioned daylight tube
- It is not easy to age and the lamp is aged.It seems to be connected to the seismograph.
- Q: The child lamp chooses led good or the lamp tube is good
- Light color chooses yellow light, because yellow light is the most natural incandescent lamp, rely on the filament to shine, current through the filament that the electric resistance is great the filament will be hot and glow. Such light is continuous no flash. And white light is the light that fluorescent lamp is called energy-saving lamp fluorescent lamp. Energy-saving lamps and fluorescent light stimulate phosphor luminescence principle is to use some kind of radiation, like light is discontinuous, which is a seaside sparkle, but quickly, eyes have a vision for the role of, feel the light in a flash. It's bad for your eyes to be in such a light for a long time.
- Q: What is the minimum starting voltage for the fluorescent tube?
- I use the 20 watt fluorescent lamp to measure the lowest maintenance of the tube and the voltage is 98V volts.
- Q: What does philips mean by TLD36w / 54-765
- Yeah, I did it for you, I think it's the bottom, Let's see if it is ~ TLD ~ T8 Dailyght 160-240v (model) 36 ~ 36 w.I hope my answer will work for you.
- Q: Fluorescent fluorescent lamp tube can replace led fluorescent lamp tube?
- When installing, the ballast is removed directly from the left and right side of the fluorescent lamp. No need to replace the lamp holder, which is completely universal.
- Q: What's the difference between an LED fluorescent lamp and an ordinary light tube?
- Leds use low power, long life, low heat and high price.Although it may feel a little bit narrower at 120 degrees, most of the time, it will be enough.
- Q: Is there a greater value in switching from a normal daylight lamp to an LED energy-saving lamp?
- The main consideration is commercial or civilian The use of civilian use is lower than that of commercial electricity Business is more appropriate The details are also calculated according to different scenarios
- Q: How do the long daylight bulbs change
- Three kinds: similar to one, but need to take off the lamp foot protection shield first. 4 four kinds: similar to 1 or 2, have lamp tube protection cover, take down protective cover first and same.
- Q: Can the T5 light tube be free of ballast?
- The T5 bulb must be ballast, and electronic ballast, no ballast to light the T5 lamp.
Send your message to us
T8 Led Lamp 1200Mm 15W 18W 22W 25W 3000-7000K 80Lm/W 50000H
- Loading Port:
- Ningbo
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 1000 Pieces pc
- Supply Capability:
- 100000 Pieces pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products