Steel Frame Grilles Square Shape for Ceiling use Air Conditioning
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 pc
- Supply Capability:
- 999999 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Steel Linear Slot Diffuser Air Grille
Supplying Air Diffusers
-Frame Thickness: 1.0mm /0.8mm
-Any Size be customed
-Powder Coated RAL 9010/9016
Specification of Air Diffuser
1 | Item | HVAC aluminum air conditioner grille |
2 | Materials | Extruded Aluminum alloy (6063-T5) |
3 | Blade | Blades in 45°from aluminum profile or as customer’s requirements |
4 | Bar spacing | 30mm as standard or as customer’s requirements |
5 | Materials | 0.8mm, 1.0mm, 1.2mm, 1.5mm or according to the customers’ |
6 | Surface Finish | Powder coated, Anodized , PVDF, Mill finish. |
7 | Size | Width x Height, any sizes available |
8 | Powder for Finish | Environmental protection and non-toxic, and Color to keep 5 -10 years. |
9 | Color | Refer to RAL colors swatch or customized colors available |
10 | Design | Drawings designed according to the customers’ requirements |
11 | Payment terms | T/T, L/C, PYAPAL, etc. |
12 | Delivery time | Usual 15-20 work days for a 40GP container |
13 | Package details | Bubble wrap + Cartons for FCL, Bubble wrap + Cartons + Wood-box for |
14 | Mesh | Stainless steel security mesh, Aluminum security mesh |
15 | Type | Fixing and adjustable installation |
Pictures Shown of Air Diffuser
Our service
Best quality + Thoughtful service + Reasonable price
Choose CNBM, PowChooseerful supplier & Best friend
1. Professional manufacturer of air vent for 7 years.
2. Factory price with high quantity and fast delivery.
3. High grade material and exquisite manufacturing acheives a good quality.
4. Freely sample is available before order.
5.Own anodized factory so diffent finish colour
· Adjustable aerofoil-designed blades provide users with the flexiblility to cater to their personal needs. Blades are individually adjustable from the face of the grilles.
· From extruded aluminum of minimum 1.0mm thickness. All grilles are manufactured from highly corrosion resistant heavy gauge aluminum.
· Corners reinforced with welded corner pieces for robust handling during installation.
· Standard powder coated white finish. Painted finish will be enamel coated and oven baked.
· Anodised finishes and other finishes are also available upon request.
Company Information
FAQ:
1, What's size do u have for round type diffuser?
A: We have face size from 150mm to 550mm,neck size from 250mm to 400mm聽
2, Do u still have other types ?
A: Yes, we have round diffuser/ rectangle diffuser/ linear grilles/ baseboard diffusers,etc
3, What's the most early delivery time?
A: Within 25 days for each 40'fcl
- Q:What is the working principle of the BOG compressor?
- With the increase of volatile gas in the tank, the tank pressure rising, in order to maintain the pressure within the allowable range, the general need to BOG compression and then condensed into liquid or compressed output. The BOG compressor is the compressor used to compress the BOG
- Q:What is the working principle of the condenser?
- Refrigeration principle general refrigerator compressor is the refrigerant by low temperature and low pressure gas compressed into high temperature and high pressure gas after temperature high pressure condenser into the liquid, through the throttle valve throttle valve, is a low temperature low pressure liquid. The liquid medium at low temperature and low pressure is sent into the evaporator to absorb heat and evaporate into low temperature and low pressure steam. It is transported into the compressor again, so as to complete the refrigeration cycle
- Q:What is the mean of condenser?
- Capable of converting gas or steam into liquid and passing heat from the tube to the air near the tube in a very rapid manner. The operation of the condenser is exothermic process, so the temperature of the condenser is higher.
- Q:What is the function and control of the evaporator and condenser of the air conditioner?
- The refrigerant in the pipeline is compressed into a high pressure state and enters the condenser. After the throttling device, the high pressure refrigerant enters the evaporator suddenly, and the pressure is reduced greatly and becomes a low-pressure gaseous state
- Q:What are the risk factors of condensers?
- Plug component is mainly carbon dioxide, water and Nitrous Oxide, especially Nitrous Oxide, has aroused more and more attention, their crystallization, blocking the main cooling channel, will cause the main cold "dry evaporation" and "dead end boiling" caused by hydrocarbon enrichment and accumulation, precipitation, the main cold blast
- Q:How to repair air conditioning compressor?
- The inspection results for the compressor power supply cord is damaged, the compressor terminal generally will rust, if simply replace the compressor wiring card terminals, due to poor contact, and the compressor when working current is large, easy to cause the fire, not a long time or will appear again the same fault, so when replacing the wiring card, must use sandpaper compressor terminal surface rust polished and clean.
- Q:What is the working principle of a two stage compressor?
- Condense it to the condensing pressure PK and drain into the condenser. In this way, the levels of pressure ratio is moderate, because after intermediate cooling, and can make the compressor power consumption is reduced, the reliability and economy are improved
- Q:What are the parts of an automobile air conditioner?
- The evaporator absorbs heat from the gas through the evaporation of the liquid refrigerant; the condenser condenses through a gaseous refrigerant that releases heat from the refrigeration system into the air outside the car
- Q:What are the differences and characteristics of D M type V compressor?
- When there is only one pair of symmetrically arranged cylinders, it is also called the D type. D is a type of M. D type represents symmetrical balance type, the cylinder is on both sides of the compressor, it is two columns, M type is symmetrical balance type, can be four or six columns, M type is equivalent to two D machines, M type range is more widely used
- Q:What is the purpose of a two-stage compression refrigeration cycle?
- Reduce the pressure ratio, avoid and reduce the loss caused by the high pressure ratio
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Steel Frame Grilles Square Shape for Ceiling use Air Conditioning
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 pc
- Supply Capability:
- 999999 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords