• SOLAX Triple Power Battery 5.8KW Lithium battery System 1
  • SOLAX Triple Power Battery 5.8KW Lithium battery System 2
  • SOLAX Triple Power Battery 5.8KW Lithium battery System 3
  • SOLAX Triple Power Battery 5.8KW Lithium battery System 4
SOLAX Triple Power Battery 5.8KW Lithium battery

SOLAX Triple Power Battery 5.8KW Lithium battery

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 unit
Supply Capability:
5000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


Traditional Solar Inverter converts direct current(DC) output of a photovoltaic (PV) solar panel into alternating current(AC) for home use. 


The excessive AC power generated by solar panel will be fed to the grid. Power supplied by the grid for home use at night.


X-Hybrid Inverter converts DC power generated by solar panels to AC power for home use and load the excessive DC power to the battery. 


Power supplied by battery for home use at night.


As a state owned company, we have been in domain of clean energy products and enery storage products for nearly 20 years. And with registered capital of nearly RMB 702 millions and 1500 employees in China, we have a strong reserach team to support our clients.


For controlling our quality of products, we have our own factory and we also make much investment in silicon. 


And our R&D team could design different kinds of products according to demands of clients to make sure that our clients could apply products in different scenes. We have servral advanced production lines like for PERC and N-Topcon etc.


Besides, we could also support our parteners with flexible payments. 


If you are interested, dont hesitate to contact us. 


Q: What is the difference between a maintenance-free battery and a conventional battery?
Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
Q: Maintenance-free battery how to detect it?
Check the height of the electrolyte at least once a month. There is no mark line of the battery, the electrolyte added to the plate 10-15mm can be higher; there are two red line of the battery, the electrolyte can not exceed the red line above.
Q: What are the advantages of maintenance-free batteries?
Maintenance-free battery using lead-calcium alloy grille, the amount of water generated when charging less water evaporation is low, with the shell with a sealed structure, the release of sulfuric acid gas is also very little, so with the above advantages.
Q: What is the meaning of the battery above 12v65Ah?
Voltage 12V, current 65AH, that is the capacity of 65A. (A is the unit of current. H is the time unit)
Q: How should the battery be well maintained?
Electrolyte density This is to evaluate whether the battery charge is normal, whether the aging of the important parameters, the use of density meter or electrolyte density tester can be measured. If the electrolyte density is too small, you need to charge. And the electrolyte concentration is too thick or too thin to a certain extent, it means that such as the occurrence of plate vulcanization, short circuit or overcharge phenomenon, this time on the need for maintenance.
Q: 80ah how much battery storage capacity?
Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
Q: What is a maintenanceable battery?
This is relative to a maintenance-free battery. Maintenance of the battery needs to be supplemented with electrolyte to ensure work, while maintenance-free is not required.
Q: Battery 200ah / 104 what does that mean?
Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Q: How does battery activation work?
Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.
Q: Lead-acid battery how to maintain?
When receiving the battery should first check whether the phenomenon of short circuit, first short circuit repair and then fill the distilled water.