Specifications

2V 150AH battery for solar system and solar panel 
1)Germany material 
2)ce,ul,msds ,cgc,tlc 
3)export experience 15 years 

wholesale price!2V 150AH battery for solar system and solar panel

1)Germany material
2)golden sun,msds ,cgc,tlc
3)export experience 15 years






  Battery Description:


Item 

    2V 150AH  gel battery 

Model NO. 

    JGFM150-2

Battery type

    GEL battery

Battery dimension

     172*102*227(mm) (L*W*H)

Nominal voltage

    2V

Nominal capacity

    150Ah

Net Weight 

    9.5kg

Cycle life 

   100%DOD  572times , 50%DOD   1485 times , 30%DOD   2406times 

Battery Case

    ABS case

Plate

    lead-antimony

Payment terms

    T/T(with 30% deposit),70% paid by the copy of BL

Loading port

   Shanghai

Main Market

  America,Africa, Mid-east,Asia ,South America, Europe


Batteru Features :

 

1. Maintenance-Free Operation 
Absorbent Glass Mat (AGM) technology ensures efficient gas recombination up to 99% and freedom from electrolyte maintenance. During the expected float service life of Prostar batteries, no need to check the specific gravity of the electrolyte or add water.
2. Good Discharging Ability
Tight assembly technology ensures an excellent high-rate discharge performance.
3. Long Service Life
A unique corrosion-resistant grid alloy ensures Prostar batteries have long service life.
4. Low Self Discharge
Using high purity raw materials ensures Prostar batteries have less self-discharge.
5. Environmental & Non-polluting
Gas Recombination technology ensures the battery high seal reacting rate, which can prevent the acid fog from separating out.
6. Safe & Reliable
Efficient venting system automatically release excess gas when the pressure rises above the normal level & reseals the valves when it returns to the normal rate, which can protect the battery from bursting.


Applied Scope :

 
1. Communication Systems: Switch, Microwave Stations, Mobile Base Stations, Data   Centers, Radio and Broadcasting Stations
2. Motivity Field: Robots, Electric Toys, Electric Tools & Portable Vacuum Cleaners
3. Solar & Wind Power Generation Systems
4. Signal System & Emergency Lighting Systems
5. EPS & UPS Systems


Photos of Factory:

Solar Power Storage Battery 2v 150ah Long Life Lead Acid Battery

Solar Power Storage Battery 2v 150ah Long Life Lead Acid Battery

Solar Power Storage Battery 2v 150ah Long Life Lead Acid Battery

Solar Power Storage Battery 2v 150ah Long Life Lead Acid Battery


FAQ of Products:


Q1 : What is you advantages

A1:

a).We are professional ups manufacturer for more than ten years and we have these staffs with rich

     production and R&D 

b) Excellent workers and skilled engineers 

c).Our aims are to provide every customer high quality, reasonable price and excellent 

    service.

d)we can guarantee to send the goods on time. And also accept any transportation ways that

    you require 

 

Q2 : How do you control the production quality

A2:

a) For materials, we have IQC departments and the IQC testing follow MIL-STD-105E standard

b) in production have 4 times function testing

c) all of our products with 100% burn-in testing

d) 100% QC testing before delivery

 

Q3 : Do you accept OEM/ODM?

A3 : ODM&OEM are warmly welcomed !!!

 

 

Q4 : what’s your payment?

A4:

a) We can accept payment terms of T/T, Western Union, PayPal

 

Samples and trial order accept PayPal ,T/T & Western Union. normal order accept T/T &Western Union 

 

b) 30% ADVANCE DEPOSIT after buyer's confirmed payment, the balance should be paid before shipping when goods are ready.




Q: What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q: What are the technical parameters of the battery?
Usually the capacity of the power supply is expressed by kV · A or kW. However, as a power supply VRLA battery, the use of security (A · h) that its capacity is more accurate.
Q: How to determine the battery is good or bad?
Observe the battery electrolyte is turbid, turbidity that the battery positive plate softening. Observe the bottom of the battery whether there is sediment, if the plate off the battery capacity has been inadequate. Hand hit the battery two electrode piles If you hear an empty voice that pole pile and plate break. With a thick wire short-circuit positive and negative pile observation of the battery filling holes, such as the discovery of a bubble appears that the interval has been damaged.
Q: What are the hazards of battery over discharge?
The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
Q: What battery does the van use?
The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
Q: What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q: What is the meaning of the battery above 12v65Ah?
12V represents the rated voltage. 65Ah indicates that the battery capacity (ie 1 ampere current can be used for 65 hours).
Q: How should the battery be well maintained?
Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
Q: How does battery activation work?
Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.
Q: Lead-acid battery how to maintain?
When receiving the battery should first check whether the phenomenon of short circuit, first short circuit repair and then fill the distilled water.