Specifications
12V 250AH battery for solar system and solar panel
1)Germany material
2)ce,ul,msds ,cgc,tlc
3)export experience 15 years
wholesale!12V 250AH battery for solar system and solar panel energy storage battery
1)Germany material
2)golden sun,msds ,cgc,tlc
3)export experience 15 years
Battery Description:
Item | 12V 250AH gel battery |
Model NO. | LCPC250-12 |
Battery type | GEL battery |
Battery dimension | 520*269*245(mm) (L*W*H) |
Nominal voltage | 12V |
Nominal capacity | 250Ah |
Net Weight | 69kg |
Cycle life | 100%DOD 572times , 50%DOD 1485 times , 30%DOD 2406times |
Battery Case | ABS case |
Plate | lead-antimony |
Payment terms | T/T(with 30% deposit),70% paid by the copy of BL |
Loading port | Shanghai |
Main Market | America,Africa, Mid-east,Asia ,South America, Europe |
Lead Acid | Nominal | Nominal | Weight | External Dimensions(mm) | |||
Length | Width | Height | Total Height | ||||
LCPA 200-6 | 6 | 200 | 32 | 243 | 187.5 | 210 | 275 |
LCPA 24-12 | 12 | 24 | 7.5 | 176 | 166 | 126 | 125 |
LCPA 33-12 | 12 | 33 | 11 | 195 | 130 | 171 | 180 |
LCPA 38-12 | 12 | 38 | 12.8 | 196 | 165 | 170 | 180 |
LCPA 50-12 | 12 | 50 | 15 | 229 | 138 | 208 | 228 |
LCPA 65-12 | 12 | 65 | 22 | 350 | 166 | 174 | 174 |
LCPA 70-12 | 12 | 70 | 22.5 | 260 | 168 | 208 | 227 |
LCPA 80-12 | 12 | 80 | 26 | 331 | 176 | 214 | 214 |
LCPA 90-12 | 12 | 90 | 30 | 406 | 174 | 209 | 238 |
LCPA 100-12 | 12 | 100 | 31 | 406 | 174 | 209 | 238 |
LCPA 120-12 | 12 | 120 | 35.5 | 483 | 170 | 240 | 240 |
LCPA 150-12 | 12 | 150 | 47 | 532 | 207 | 214 | 240 |
LCPA 200-12 | 12 | 200 | 58 | 522 | 140 | 219 | 244 |
LCPA 250-12 | 12 | 250 | 67 | 520 | 269 | 219 | 245 |
Batteru Features :
1. Maintenance-Free Operation
Absorbent Glass Mat (AGM) technology ensures efficient gas recombination up to 99% and freedom from electrolyte maintenance. During the expected float service life of Prostar batteries, no need to check the specific gravity of the electrolyte or add water.
2. Good Discharging Ability
Tight assembly technology ensures an excellent high-rate discharge performance.
3. Long Service Life
A unique corrosion-resistant grid alloy ensures Prostar batteries have long service life.
4. Low Self Discharge
Using high purity raw materials ensures Prostar batteries have less self-discharge.
5. Environmental & Non-polluting
Gas Recombination technology ensures the battery high seal reacting rate, which can prevent the acid fog from separating out.
6. Safe & Reliable
Efficient venting system automatically release excess gas when the pressure rises above the normal level & reseals the valves when it returns to the normal rate, which can protect the battery from bursting.
Applied Scope :
1. Communication Systems: Switch, Microwave Stations, Mobile Base Stations, Data Centers, Radio and Broadcasting Stations
2. Motivity Field: Robots, Electric Toys, Electric Tools & Portable Vacuum Cleaners
3. Solar & Wind Power Generation Systems
4. Signal System & Emergency Lighting Systems
5. EPS & UPS Systems
Photos of Factory:
FAQ of Products:
Q1 : What is you advantages
A1:
a).We are professional ups manufacturer for more than ten years and we have these staffs with rich
production and R&D
b) Excellent workers and skilled engineers
c).Our aims are to provide every customer high quality, reasonable price and excellent
service.
d)we can guarantee to send the goods on time. And also accept any transportation ways that
you require
Q2 : How do you control the production quality
A2:
a) For materials, we have IQC departments and the IQC testing follow MIL-STD-105E standard
b) in production have 4 times function testing
c) all of our products with 100% burn-in testing
d) 100% QC testing before delivery
Q3 : Do you accept OEM/ODM?
A3 : ODM&OEM are warmly welcomed !!!
Q4 : what’s your payment?
A4:
a) We can accept payment terms of T/T, Western Union, PayPal
Samples and trial order accept PayPal ,T/T & Western Union. normal order accept T/T &Western Union
b) 30% ADVANCE DEPOSIT after buyer's confirmed payment, the balance should be paid before shipping when goods are ready.
- Q: How is the capacity of the battery defined?
- General circuit has a battery protection circuit, once the battery voltage is less than 10.8V will automatically cut off the electricity to prevent the battery because of over-discharge and damage. (Nominal value of 12V battery internal six cell grid) with the battery discharge current multiplied by the discharge time to express how much energy the battery can store, is a very image of a measure. The greater the value of the battery, indicating that the battery can store more energy. But does not mean that the battery can use such a large current discharge.
- Q: What is the difference between a maintenance-free battery and a conventional battery?
- Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
- Q: What are the technical parameters of the battery?
- Usually the capacity of the power supply is expressed by kV · A or kW. However, as a power supply VRLA battery, the use of security (A · h) that its capacity is more accurate.
- Q: How to determine the battery is good or bad?
- Instrument test: the general use of battery discharge tester, the test instrument two positive and negative clamp were holding the battery positive and negative electrodes, press the test button to observe the test instrument instructions.
- Q: What are the advantages of maintenance-free batteries?
- The advantage of a maintenance-free battery is that the service life is twice as long as the dry battery! And in the use of the process without maintenance! The voltage is also relatively stable.
- Q: What is the meaning of the battery above 12v65Ah?
- 12V is said to be the voltage, 65Ah is the current. (A is the unit of current. H is the time unit .1 hours.)
- Q: How does the battery increase the voltage?
- With the same battery pack in series; if the required current is relatively small, you can use DC-DC module.
- Q: What is a maintenanceable battery?
- Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
- Q: Battery 200ah / 104 what does that mean?
- Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
- Q: Lead-acid battery how to maintain?
- After passing the test, cover the exhaust cutting, pay attention to restore the filler, cover the battery cover, if the cover is glued, then glue bonding.
Send your message to us
Solar Power Storage Battery 12v 250ah Long Life Lead Acid Battery
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords