Sell Heat Recovery Ventilation Unit
- Loading Port:
- Shanghai
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 1 Unit set
- Supply Capability:
- 6000 Units set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Features:
1) The film of the filter is very small, you almost cannot see the fiber constitution of the air hole that reduces the circulating ratio of water- solubility gas, such as ammonia and hydrogen.
2) The crossing airflow board is made of a kind of environment protection board. With the high hydrosphere particularity, it helps the exchange of the vapor that improves the exchanging efficiency of the heat and reaches the conversion of low efficient gas and high efficient heat.
Model | Power | Air flow (m3/h) | Output static pressure(Pa) | Temperature efficiency(%) | Enthalpy efficiency | Rated power (W) | Noise dB(A)* | |
Chill room | Warm room | |||||||
ALH1-15RX3 |
220 /50Hz | 150 | 80 | 73-87 | 58-63 | 78-83 | 100 | 27 |
ALH1-20RX3 | 200 | 95 | 72-85 | 57-62 | 76-82 | 125 | 28 | |
ALH1-25RX3 | 250 | 85 | 75-89 | 60-66 | 83-86 | 125 | 32 | |
ALH1-30RX3 | 300 | 120 | 73-87 | 58-63 | 79-83 | 155 | 33 | |
ALH1-35RX3 | 350 | 145 | 75-91 | 60-65 | 84-86 | 242 | 35 | |
ALH1-40RX3 | 400 | 155 | 73-87 | 59-63 | 82-84 | 250 | 36 | |
ALH1-50RX3 | 500 | 160 | 75-90 | 61-66 | 84-87 | 280 | 38 | |
ALH1-60RX3 | 600 | 175 | 73-87 | 60-64 | 81-83 | 350 | 42 | |
ALH1-80RX3 | 800 | 140 | 74-90 | 62-66 | 83-86 | 470 | 46 | |
ALH1-100RX3 | 1000 | 155 | 74-89 | 63-67 | 84-87 | 650 | 47 | |
ALH1-125RX3 | 1250 | 180 | 72-87 | 62-65 | 82-85 | 940 | 48 | |
ALH1-150RX3 | 1500 | 150 | 74-89 | 63-67 | 83-86 | 890 | 50 | |
ALH1-200RX3 | 2000 | 150 | 76-90 | 63-68 | 84-87 | 1270 | 50 | |
ALH1-250RX3 | 2500 | 180 | 73-87 | 62-66 | 81-83 | 1570 | 51 | |
Model | Power | Air flow (m3/h) | Output static pressure(Pa) | Temperature efficiency(%) | Enthalpy efficiency | Rated power (W) | Noise dB(A)* | |
Chill room | Warm room | |||||||
ALH-30BX3 | 220 /50Hz | 300 | 60 | 70-82 | 54-59 | 73-81 | 130 | 28 |
ALH-35BX3 | 350 | 75 | 78-80 | 53-57 | 72-79 | 180 | 31 | |
ALH-50BX3 | 500 | 80 | 65-76 | 52-57 | 71-78 | 240 | 33 |
Why we choose Okorder.com?
Okorder.com is a professional and reliable online E-market place
Providing a variety of products with reasonable prices
High quality goods provided by factory suppliers
Shipping to over 200 countries.
One-stop sourcing
Dubai Logistic Complex
Okorder Quality Control?
We hold a very strict quality control system to check every connector of our products for your safety.
- Q: How to buy a washing machine?
- Capacity: in dry clothes weight meter. At present, 6 kg dry clothing capacity of the highest cost-effective, but also the main manufacturers of the capacity belt. 6 kg machine can be convenient to wash, quilt and other large pieces.
- Q: What is the use of waxing machine?
- The liquid wax ring like smear on the wax disc, each with 0.5 m2 area well, until the whole car finished
- Q: How to clean the fan leaves of the range hood?
- The first newspaper in the kitchen floor, open the switch "lampblack machine preheating" fan for two minutes, to fan the lampblack machine sprayed detergent, turn off the cooker, set aside for three minutes, and then hot water spray fan 60 DEG C into the lampblack machine, then turn on the switch, let the oil dissolved drop to the storage box
- Q: What are the domestic development prospects of the washing machine?
- As the country carries out the policy of "home appliances to the countryside" and "expanding domestic demand", the washing machine enterprises have turned their attention to the rural market with larger consumption potential
- Q: What is the mean of Smoke lampblack machine?
- With anti-virus, explosion-proof security role. The range hood should be cleaned regularly, and the oil can not be removed by simple cleaning. The cleaning hood must be cleaned with professional cleaning agent
- Q: What is the basic structure of the washing machine?
- The rib plate is circular plate with convex edges, four contour edge and the base respectively, port ring and side wall connection, and is provided with a connecting structure, board is provided with a plurality of dehydration through hole; the side wall and the rib plate are connected with each other to form a cylindrical tube, a convex convex edge the edges of the plate to the cylinder projection, lifting rib effect.
- Q: How do I disinfect the washing machine?
- Laundry fungus spores: the number of fungal spores in the fully automatic washing machine is more than that of the semi-automatic washing machine. Therefore, washing clothes should be emptied of the washing machine in time, and open the lid, conditions can use disinfectant cabinets or clothing disinfectant; underwear best hand washing
- Q: What are the points for attention of the hood?
- The exhaust gas from the hood shall not be discharged into the hot flue used for discharging smoke or other fuel, so as to prevent fire.
- Q: What are the features of the washing machine without washing?
- Avoid cleaning adopt physical "smart bath": when washing clothes, the wisdom of the ball from the recycling compartment pops up, with the inner barrel of the washing machine movement, through physical exercise frequency, no dead shot inside and outside of the tank wall, away stains; water, wisdom ball with the water level dropped back to back stripping, waiting for the next time by using the
- Q: Lampblack machine does not take lampblack, what problem can cause?
- Long term no thorough cleaning, excessive oil, greasy check valve, resulting in poor smoke absorption effect, it is recommended to regularly clean up the flue gas
Send your message to us
Sell Heat Recovery Ventilation Unit
- Loading Port:
- Shanghai
- Payment Terms:
- L/C,T/T
- Min Order Qty:
- 1 Unit set
- Supply Capability:
- 6000 Units set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords