rod/cable probe radar level transmitter manufacturered in China
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 5000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
features:
Owing to adopted advanced micro processor and special Echo processed technology,the radar level meter can be applied in any kinds of complicated working environment
False echo saving function make the meter can select the correct echo out of a large number of interfering reflections,obtained the correct measured results.
Multi process connecting method and antenna shape make CMAXS60 serial radar level meter suitable to any kinds of complicated working environment.for example:high temperature,high pressure and small dielectric constant media measurement and so on.
Adopting pulse work method can make the meter has lower transmitting power,and suitable to install into any metal or non-metal vessel,no harm to people and environment.
Principle:
The antenna of Radar level meter emits extreme short microwave pulse to the measured media surface and reflects to the same antenna with the speed of light,the time from emission to receiption of the signals is proportional to the level in the vessel.
GUIDEPULS60 serial radar level meter adopted special related demodulation technology,they can correctly judge the time from emission and reception of the signals to calculate the distance between the antenna and the surface of measured media.
Input:
the antenna receive the reflected microwave and transmit to current circuit ,microprocessor processed the signal,to read out the reflected microwave from the surface of the measured media.intellectual software select the correct signal and accuracy can reach millimeter degree.the distance(D) to the measured media is proportional to the running time of the pulse(T)
D=C×T/2 C:speed of light.
empty vessel distance(E) is known,then the level(L)=E-D
Output:
By inputing empty height(E)(= zero point),full vessel height(F)(=Max.measuring range) and some applied parameters to set,applied parameters can make the meter adapting to the measured environment.corresponding to 4-20mA output.
When the antenna emits microwaves,there should have emission angel.the area that emited microwaves radiated between the bottom of the antenna and surface of measured media should not have barrier ,so when installing,do best to keep away of facilities in vessel,just like:ladder,limit switch,heating equipment,and bracket.when it is unable to keep away,when installing,we should do false echo saving.we should note that microwave and filling flow can not intersect.the Max. level of the media should not enter into dead zone,there is certain distance between the level meter and vessel wall.when installing,the best is to make the emission direction of the antenna is vertical to surface of measured media.when installing in the area of anti-explosion,we must abide by national installation stipulation,the housing material of the intrinsic safety type level meter is aluminum,it is suitable to install in the anti-explosion area,the housing of the meter should connect to ground.
the area from measured reference plane to the bottom of the antenna is the dead zone of the level meter(reference plane is the seal surface of thread or flange)
Power supply cable can use normal two core cable,the outside diameter should be 5...9mm to make sure to seal the inlet port of cable.if there is electromagnetic interference,use shield cable.
4...20mA/HART(two wire) Power supply cable can use normal two core cable
4...20mA/HART(four wire)
CMAXS60 has 3 debugging methods:
1,display/debug module(programmer)
2,upper computer debugging GDPFSOFTWARE
3,HART handheld programmer
display/debug module(programmer)
Programmer is pluggable debugging tool,to debug by 4 keys,after bebugging,it is easy to read measured datas through the display screen of the programmer and display window on the meter cover.
- Q: How are hand powered tools classified into class I, class II, class III?
- Simple methods are: hand-held electric tools for metal shell for class I. The plastic case is of the type ii. Class III uses safe voltage.
- Q: What are the common rotors of power tools?
- Electric drill: the main specifications are 4, 6, 8, 10, 16, 19, 23, 25, 32, 38, 13, 49mm and so on. Figures refer to the maximum diameter of the drill drilled on the steel whose tensile strength is 390N/mm. For non-ferrous metals, plastics and other materials, the maximum drilling diameter is comparable to the original specifications of 30 to 50%.Electric grinding machine: a tool for grinding with a grinding wheel or millstone. A vertical electric wheel and electric angle grinder.Electric wrench and electric screwdriver: used for loading and unloading threaded fittings. The driving mechanism of the electric wrench is composed of a planetary gear and a ball screw groove impact mechanism. Specifications are M8, M12, M16, M20, M24, M30 and so on. The electric screwdriver adopts the embedded clutch, transmission mechanism or gear drive mechanism. The specifications include M1, M2, M3, M4, M6 and so on.
- Q: What kind of power tools are hand drills? 1, 2 or 3?
- You can see the cable plug, the aluminum shell is inserted three I tools, is grounded, the aluminum shell and some II tools, because it has a plastic insulation between the stator and the aluminum shell, so it is the installation of two wire plug.
- Q: Is Li Xiang power tool good?
- About the same price, choose a good reputation, East into good
- Q: How are the I, II, and III classes of power tools classified?
- In accordance with the electric shock protection methods, electrical equipment is divided into the following 4 categories:0 category. The device relies solely on basic insulation to prevent electric shocks. There are no ground terminals on the live conductors of the 0 types of equipment.
- Q: Compared to pneumatic tools, what are the advantages of electric tools?
- The pneumatic tool is more environment-friendly, energy-saving, and has better environmental adaptability, and is safer than an electric tool. The pneumatic tool has the advantages of simple structure, convenient operation, long service life and convenient maintenance
- Q: What power tools are used as cage birds?
- An electric drill or a small bench drill, drill speed is the best because of the speed change drill, drill hole spacing and easy consumption. If you want to do with special accessories can also change the distribution of wood milling, milling machine, special safety and easy to do.
- Q: What material does the power tool housing fit?
- The hammer and drill: used for concrete, brick and building components on drilling, slotting, dehairing. Combined with expansion bolt, various pipelines can be improvedInstallation speed and quality of machine tools.Concrete vibrator: used for pouring concrete foundation and reinforced concrete members, tamping concrete to eliminate air holes and increase strength. Among them, electric straightThe high frequency disturbing force of the combined vibrator is driven by the motor to rotate the eccentric block, and the motor is powered by 150Hz or 200Hz intermediate frequency power supply.The planer: used for planing wood or wood structure, mounted on the bench can be used as a small bench plane. The planer cutter shaft by the motor shaft through the belt drive
- Q: What devices must be available for all hand held electric tools?
- Hand held electric tools, insulation measures are in good condition, must be equipped with qualified leakage protection device, forbid to change the power cord and plug, use special flow switch box.
- Q: How to detect the rotor of power tools?
- Rotor inspection. 1) a self made short circuit device can detect damage. 2) you can detect with a pointer type multimeter.
Send your message to us
rod/cable probe radar level transmitter manufacturered in China
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 5000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords