electronic level gauge manufactured in China
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 5000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
features:
Owing to adopted advanced micro processor and special Echo processed technology,the radar level meter can be applied in any kinds of complicated working environment
False echo saving function make the meter can select the correct echo out of a large number of interfering reflections,obtained the correct measured results.
Multi process connecting method and antenna shape make CMAXS60 serial radar level meter suitable to any kinds of complicated working environment.for example:high temperature,high pressure and small dielectric constant media measurement and so on.
Adopting pulse work method can make the meter has lower transmitting power,and suitable to install into any metal or non-metal vessel,no harm to people and environment.
Principle:
The antenna of Radar level meter emits extreme short microwave pulse to the measured media surface and reflects to the same antenna with the speed of light,the time from emission to receiption of the signals is proportional to the level in the vessel.
GUIDEPULS60 serial radar level meter adopted special related demodulation technology,they can correctly judge the time from emission and reception of the signals to calculate the distance between the antenna and the surface of measured media.
Input:
the antenna receive the reflected microwave and transmit to current circuit ,microprocessor processed the signal,to read out the reflected microwave from the surface of the measured media.intellectual software select the correct signal and accuracy can reach millimeter degree.the distance(D) to the measured media is proportional to the running time of the pulse(T)
D=C×T/2 C:speed of light.
empty vessel distance(E) is known,then the level(L)=E-D
Output:
By inputing empty height(E)(= zero point),full vessel height(F)(=Max.measuring range) and some applied parameters to set,applied parameters can make the meter adapting to the measured environment.corresponding to 4-20mA output.
When the antenna emits microwaves,there should have emission angel.the area that emited microwaves radiated between the bottom of the antenna and surface of measured media should not have barrier ,so when installing,do best to keep away of facilities in vessel,just like:ladder,limit switch,heating equipment,and bracket.when it is unable to keep away,when installing,we should do false echo saving.we should note that microwave and filling flow can not intersect.the Max. level of the media should not enter into dead zone,there is certain distance between the level meter and vessel wall.when installing,the best is to make the emission direction of the antenna is vertical to surface of measured media.when installing in the area of anti-explosion,we must abide by national installation stipulation,the housing material of the intrinsic safety type level meter is aluminum,it is suitable to install in the anti-explosion area,the housing of the meter should connect to ground.
the area from measured reference plane to the bottom of the antenna is the dead zone of the level meter(reference plane is the seal surface of thread or flange)
Power supply cable can use normal two core cable,the outside diameter should be 5...9mm to make sure to seal the inlet port of cable.if there is electromagnetic interference,use shield cable.
4...20mA/HART(two wire) Power supply cable can use normal two core cable
4...20mA/HART(four wire)
CMAXS60 has 3 debugging methods:
1,display/debug module(programmer)
2,upper computer debugging GDPFSOFTWARE
3,HART handheld programmer
display/debug module(programmer)
Programmer is pluggable debugging tool,to debug by 4 keys,after bebugging,it is easy to read measured datas through the display screen of the programmer and display window on the meter cover.
- Q: What are the commonly used rotor types for power tools?
- Concrete vibrator: concrete used for pouring concrete foundations and reinforced concrete members to eliminate porosity and increase strength. The high-frequency disturbing power of the electric direct acting vibrator is driven by an electric motor to rotate the eccentric block, and the motor is powered by an 150Hz or 200Hz intermediate frequency power supply.The planer: used for planing wood or wood structure, mounted on the bench can be used as a small bench plane. The planer cutter shaft by the motor shaft through the belt drive.
- Q: Which is good between pneumatic tools and power tools?
- The utility model relates to an electric tool, which is a hand-held or movable mechanical tool, which is driven by an electric motor or an electromagnet, and is driven by a transmission mechanism to operate the working head. Electric tool has the characteristics of portability, simple operation, multiple functions, can greatly reduce labor intensity, improve work efficiency, realize the mechanization of manual operation, which is widely used in building, housing decoration, automobile, machinery, electric power, bridges, gardening and other fields, and poured into the family.
- Q: What are the common rotors of power tools?
- Power tools are mainly divided into metal cutting, power tools, grinding power tools, assembly of power tools and railway power tools. Common electric tools electric drill, electric grinder, electric wrench and electric screwdriver and hammer, impact drill, concrete vibrator, planer. Accessories for each power tool: rotor, stator, gear, bearing, switch, carbon brush, carbon brush holder, carbon brush cover, power cord. Go down and stop repeating.
- Q: What safety problems should we pay attention to when using electric drills or hand-held power tools?
- All conducting parts must be well insulated,
- Q: What's the role of carbon brushes in electric tools?
- In addition to induction type AC asynchronous motors, there is no outside. Other motors are provided, as long as the rotor has a reversing ring.The principle of electric power generation is that a magnetic field cuts a wire to produce an electric current in the wire. The generator cuts the wires by rotating the magnetic field. A rotating magnetic field is a rotor, and the wire to be cut is a stator.
- Q: How are the I, II, and III classes of power tools classified?
- Class I. In addition to basic insulation, the device has an additional safety measure. There is no grounding terminal on the shell of class I equipment, but there is a grounding terminal inside, and the power cord with protective plug is drawn out from the equipment.Class ii. The device has dual insulation and insulation protection measures.Class III. The device relies on extremely low safety voltages to protect against electrical shocks.
- Q: Why hand grinding sand turbine, electric drill, impact drill and other power tools plug is two, plug is not three plug
- Hand-held power tools, in the past there are many plugs with three eyes, the purpose is that in case the leakage can pass through the grounding wire, the current will be introduced into the earth, and the protection of the human body.In practical applications, because of the mobile work and the use of temporary power supply, and the grounding of the sockets in many places is not reliable, it is not ideal to implement the leakage protection by grounding.
- Q: Is the motor of an electric tool the alternating current motor or the direct current motor?
- The motor of a general electric tool is an alternating current motor.
- Q: What devices must be available for all hand held electric tools?
- Anti leakage, splash prevention, anti movement, anti overheating
- Q: How to detect the rotor of power tools?
- Rotor inspection. 1) a self made short circuit device can detect damage. 2) you can detect with a pointer type multimeter.
Send your message to us
electronic level gauge manufactured in China
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 5000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords