R410a Gas Floor Air-Condition Units
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 30 Sets set
- Supply Capability:
- 1000 Sets per Day set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.brand compressor
2.gas: R22 or R410a
3.moq:30pcs
4.certificate: CCC, CE
5.with 1% spare parts free of charge
6.the compressor gurantee 5 years and the spare parts 1 year
Features and functions:
1.capacity rang: 18000btu, 240000btu,30000btu,360000btu,40000btu,42000btu,50000btu,60000btu
2.use the name brand type compressor
3.led temperature digital display
4.self-diagnose capabilty, error code showing
5.sleeping mode, remote control
6.power supply; 220v~240v/50~60hz
7.refrigerent: R22 or R410a
- Q: Yituo 2 how to install air conditioning
- 1. The installation method: (1) the interface connection; Connection bell mouth, to aim at, straighten, compaction, A successful fight seg group A and group B of high pressure tube, low pressure pipe wrong. (2) piping system tightness inspection; Operation should be careful. (3) keep piping clean; Pipe wall should avoid dust; Rule out the air in the pipeline, should be more than 3 times, each time 3 ~ 4 seconds. (4) avoid errors; Yituo two air-conditioning attachment is more, should pay attention to distinguish between group A and group B connection order accordingly. 2. Maintenance methods: (1) the double pressure table; Double table should be installed in the group A and group B two outdoor low-pressure valve thimble outlet, in order to observe the comparison and analysis of judgment. (2) the refrigerant filling quantity should be accurate; Take the double pressure, can timely observe A, B two running situation of piping system, the refrigerant filling quantity. (3) the back pressure detection: the method for overhaul of yituo 2 air conditioning is very important, double table pressure generally observed A, B two system of capillary, filter, in the case of downtime when the back pressure, can also be observed in the balance of the two static pressure circuit is normal and easy to find the point of failure.
- Q: What are the several types of general family expenses air conditioning?
- 1, air conditioning air conditioner (air conditioner), also known as the air conditioning. Refers to the use of artificial means, within the buildings/structures on the ambient air temperature, humidity, cleanliness, speed and other parameters to adjust and control the process. 2, generally including cold source and heat source equipment, hot and cold media distribution system, terminal device such as a few most and other auxiliary equipment. Mainly include water pump, fan and piping system. Terminal device is responsible for the use of distribution to the cold heat, specific processing air, air parameters of the target environment is achieved
- Q: Open the wastage of the dehumidification function of air conditioning for a long time
- 1. The difference is that dehumidification relative to the refrigeration, air volume small, the working frequency is low, open dehumidification function of air conditioning for a long time damage is not big. 2.1 we contact with the air is a mixture of dry air and water vapor, under certain conditions of temperature, 1 kg dry air can let of steam is limited, when reach perfection, we referred to as the saturation state. The state of air dry bulb temperature, wet bulb temperature, dew point temperature is the same. 2.2 the air cooling to the dew point temperature temperature, condensation of water vapor in the air will precipitate, air saturated state. 2.3 air conditioning dehumidification principle that when air flows through the indoor evaporator, as a result of the evaporator cooling effect of cooling air temperature below the dew point temperature, so the part of the water vapor in the air condenses into water precipitation, so as to achieve the aim of dehumidification. 3. The general family expenses air conditioning has a model can be directly set as dehumidification function, if not, you can set for ordinary refrigeration air conditioning mode, switch to a minimum, wind speed set temperature down as far as possible, also can achieve the goal of fast dehumidification.
- Q: Install the central air conditioning home?
- See how big is your area, If conditional word, of course, your home is the best!
- Q: Recently to do some engineering of hvac engineering, they want to install VRV aircon on the first floor, central air conditioning in the second and third floor, I don't understand, these two kinds of air conditioning is not the same? Had heard that VRV aircon is the central air conditioning! The whole central air conditioning is not good?
- Frequency VRF, central air conditioning circulation medium is water system, is Buddha system and VRV circulation medium, is there a difference!
- Q: Can an air conditioner be used in a conference room?
- Yes, an air conditioner can be used in a conference room. In fact, it is often necessary to have adequate air conditioning in a conference room to ensure the comfort of the attendees. The air conditioner helps regulate the temperature and humidity levels, creating a pleasant and conducive environment for discussions and presentations. Additionally, air conditioning also helps improve air quality by filtering out dust, allergens, and other pollutants, which can be beneficial for individuals with respiratory issues or allergies. Overall, using an air conditioner in a conference room is not only feasible but also essential for creating a comfortable and productive atmosphere.
- Q: Household air conditioning with much thread
- Household type has a split type and central air conditioning. Separation is generally the largest 5 horses ark. Usually 3, suggest four square. Wall hang two horses under 2.5 square will be enough.
- Q: How do you check the thermostat sensor on an air conditioner?
- To inspect the thermostat sensor on an air conditioner, the following steps can be followed: 1. Find the thermostat: Typically, the thermostat can be found on the interior wall near the air conditioning unit. It is a small device equipped with buttons or a digital display. 2. Power off: Prior to examining the thermostat sensor, it is crucial to turn off the power to the air conditioner. This can be achieved by either switching off the circuit breaker or unplugging the unit. 3. Remove the thermostat cover: Carefully detach the cover of the thermostat by unscrewing or sliding it off. Be cautious not to cause any damage to the wires or components. 4. Identify the sensor: Once the cover is removed, the thermostat sensor will become visible. It is a small, cylindrical metallic object resembling a bulb. Typically, it is situated near the front of the thermostat. 5. Clean the sensor: Utilize a soft cloth or a cotton swab dipped in isopropyl alcohol to cleanse the thermostat sensor. Gently wipe away any accumulated dirt, dust, or debris. Ensure that the sensor is completely dry before proceeding. 6. Check the sensor connection: Inspect the wiring connections of the sensor to ensure they are secure and not loose. If any loose or damaged wires are found, they may require repair or replacement. 7. Reassemble and test: After cleaning the sensor and inspecting the connections, reassemble the thermostat cover. Restore power to the air conditioner and set the thermostat to the desired temperature. Allow a few minutes to observe if the air conditioner begins functioning correctly. If the air conditioner continues to exhibit unexpected behavior or if there is suspicion of a faulty or malfunctioning sensor, it is advisable to seek the assistance of a professional HVAC technician who can accurately diagnose and address the issue.
- Q: Air conditioning separate-bodied air-conditioners installed can higher than indoor machine
- No, as long as the indoor machine loading level. Out the water out
- Q: Are air conditioners safe to use around children and pets?
- Yes, air conditioners are generally safe to use around children and pets. However, it is important to take certain precautions to ensure their safety. Firstly, make sure that the air conditioner is installed properly and securely, keeping it out of reach of children and pets to prevent any accidents. Additionally, it is recommended to regularly clean and maintain the air conditioner to prevent the accumulation of dust, mold, or other allergens that could potentially harm children or pets. It is also important to keep the temperature at a comfortable level and avoid extreme temperature changes, as this can sometimes affect the health of children and pets. Overall, as long as proper safety measures are taken, air conditioners can be used safely around children and pets.
1. Manufacturer Overview
Location | Foshan, China (Mainland) |
Year Established | 2009 |
Annual Output Value | |
Main Markets | |
Company Certifications | ISO 9001:2000; ISO 14001:2004 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | 3,000-5,000 square meters |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
R410a Gas Floor Air-Condition Units
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 30 Sets set
- Supply Capability:
- 1000 Sets per Day set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords