R290 200L 300L all in one air source heat pump with Energy efficient class: A++
- Loading Port:
- SHANGHAI
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
Specification
Model:
YT-200TA2
Tapping Cycle:
L
Energy Efficient ηwh (%):
154.5
Rated Heating Capacity(kW):
2.4kw
- Q: Why can't the air conditioning compressor be used in the heat pump water heater?
- Long term stable operation without faultsCompared with the air conditioner, the running time of the heat pump water heater is very different, and the operation time of the heat pump water heater system is much higher than that of the air conditioner. The running time of a heat pump water heater depends on the following factors:
- Q: The heat efficiency of an air heater is over 100%. Why?
- The air energy heater uses only a large amount of free heat energy in the air to consume electricity. It is only the energy that the compressor uses to transport air energy, so the thermal efficiency is as high as 380%-600%
- Q: What is the size of the heat pump water inlet and outlet?
- Here are some pictures. You can see that the sizes of the different models are different:
- Q: Electric heating and heat pump heating that efficiencyWith the electric heating tube heating or PTC, and with the heat pump refrigerant, the high efficiency high?? the energy consumption is small, small? Please enlighten.I know that one is to convert electrical energy into heat energy, another is the transmission of heat, like Kano, but I want to know what the difference? For example, in the summer, if the heat pump heating bath water, than the electric water heater is used in winter, heating and air conditioning heating heater PTC which province energy about, province? Or what percentage?
- There are three ways of using electric assistant in engineering:1 、 the water heater in the heating unit of the engineering unit is provided with electric assistance to improve the water inlet temperature of the unit. It is helpful to the operation of the unit and is beneficial to the operation of the unit in winter2. The water tank is directly loaded with electricity, and the heating time and water temperature are limited by the temperature control. For example, when the ambient temperature is lower than a certain setting temperature, the electric auxiliary is switched on, and the water temperature is closed when a certain temperature is set, which is beneficial to the normal hot water supply3, the water tank built-in electric auxiliary temperature control restrictions, constant temperature water inlet, such as 50 degrees water inlet, 70 degrees to stop work, this method can shorten the working time of the unit, prolong the compressor life
- Q: What is the difference between air source heat pump water heater and solar energy?
- Is the heat pump water heater solar energy product? What's the difference between it and solar water heater?Answer: in broad sense, heat pump water heaters belong to solar energy products, from the principle of work, does not belong to the traditional solar products. It is essentially different with the conventional solar water heaters, mainly reflected in the different working principle: conventional solar water heater must rely on exposure to direct sunlight or heat radiation system to achieve results, and if the party according to the principle of Kano heat pump heating, the refrigerant absorbs heat energy and solar radiation in the air and through the compressor compression heating heat exchange with water to achieve the heating effect.
- Q: Is the heat pump water heater equipped with leakage protection plug?
- It seems that there is no match, only a cable, one machine may be there!
- Q: Is the development corridor suitable for air powered heat pumps?
- The more you use, the more you save money, the more you recycle the air conditioner,
- Q: What about solar heat pump water heater?
- (5) has the advantages of convenient installation, long service life: the whole system adopts the split structure, convenient installation, and the installation position of solar collector / evaporator almost unlimited, piping system pressure type hot water storage tank is also very simple; refrigeration pipeline corrosion and winter "freezing" problem, the system life can reach more than 10 years.(6) the use of comfort: the vertical bearing heat preservation water tank and transverse scattering entering hole, reducing the cold and hot water mixing, is conducive to the temperature stratification in the water tank, improve the effective utilization rate of hot water and cold, hot phenomenon does not appear.(7) to realize the integration and construction: rely on the rational design of solar collector / evaporator can be combined with the implementation of the integration of the building, can not only enrich the architectural appearance; and can enhance the maintenance of the structure of the thermal insulation performance.
- Q: I heard that there is a kind of air heater. It is specially used in hair salons. It is very energy-saving
- Air water heater absorbs heat from the air, is not cloudy, rain and fog, floor conditions, even if the cold winter is still normal hot water system.Niuen Tai air heaters, what are the advantages?"Safety + save money + comfort + environmental protection""1, safety: do not use gas, will not produce any exhaust gas, and will not appear "gas poisoning"; do not use electric heating rod heating, there will be no leakage of dangerous, care for the health and safety of the family.2, save money: COP value of more than 3, high energy efficiency ratio, absolute power saving, money saving. 2/3~3/4 power savings can be saved, or 1/2~2/3 gas costs and the auxiliary heating costs of solar water heaters can be saved.3, comfortable: Niuen Tai quantum patented technology, automatic constant temperature and pressure in water supply, water use will not have hot water pressure, sometimes hot and sometimes cold, good comfort. All-weather hot water supply, make up the solar energy in the rainy day and night, no sunshine, no hot water available embarrassment frozen.
- Q: Advantages and disadvantages of direct heating heat pump water heater?
- Comprehensive energy efficiency here, the comprehensive energy efficiency, mainly refers to two points, one is the heat pump unit itself energy efficiency, one is the water pump power consumption, in general, the heat pump input power is not included in the pump power. In general, the condensing pressure and condensing temperature of direct heating is relatively stable, the energy efficiency is relatively stable and easy to be measured, the circulating efficiency varies with the water temperature, the energy efficiency is not easy to measure. In the same configuration system, the average energy efficiency of the direct heating unit is higher than the cycle type 0.1-0.3
Send your message to us
R290 200L 300L all in one air source heat pump with Energy efficient class: A++
- Loading Port:
- SHANGHAI
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 1000 pc/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches