2.4kw Energy Saving a++ Split Type Radiator Heating and Cooling Heat Pump All in One Heating
- Loading Port:
- SHANGHAI
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 5000 pc/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
Specification
Power Supply:
220~240V/1/50Hz
Energy Efficient ηwh (%):
154.5
Tapping Cycle:
L
Rated Heating Capacity(kW):
2.4
- Q: Kd55/200-ac3 power consumption of air source water heater
- The auxiliary heating tube of the heat pump belt is used for auxiliary heating in winter when the temperature is low and the compression mechanism is not enough.
- Q: I would like to ask the hair salon has eight shampoo beds, which brand of heat pump water heater is better, and the price is reasonable, please know the friend issued comments, thank you!
- Understand that the salon with beautiful fountain series is more suitable, you can ask, see how much the price is not clear,
- Q: Can air source heat pump water heater be used for hot water use and ground heating at the same time?
- We have not done that, heat pump water heater common output power is about 3-4KW, not enough heating, more than 20 square meters estimated okay, if the hot water heating are used, the water tank is not to return to the backwater interface, tap water inlet, with electric three-way valve, no hot water return basic do not want to. Even if there is a mess (finished completely mess, you used to warm the water into the water tank, a dirty dead, in the outlet of the water tank and back to the three through the heating hot water water pump)
- Q: How many degrees a month does the heat pump water heater take?
- Electric water heater: advantages: low price, and can adapt to any weather changes, as long as the power can be used at any time. Disadvantages: 1., bulky, occupy large indoor space, easy to scale, a large waste of electricity, use up, electricity is expensive. 2., easy to scale, anode magnesium bar must be replaced two years, causing trouble to the maintenance. 3., the most important still exist hidden danger of electric leakage, the existence of electric dead person
- Q: How can I add snow to an air - powered heat pump water heater?
- In the state of normal operation of the water heater, the electromagnetic coil of the four way reversing valve is taken down or the four way reversing valve is switched off
- Q: 5 heat pump water heater. With 5 tons of insulation box, at about 10 degrees. How many hours can it reach 55 degrees?
- Then divide it by 860 kcal / kwThat's 225000/860=261 kilowattsThen look at your choice of heat pump water heater brand 5 units at 10 degrees Celsius, water temperature of 55 degrees Celsius when the output power, that is, heat
- Q: Is the development corridor suitable for air powered heat pumps?
- Yes, the 6P salon is enough, but the initial investment is a little big
- Q: Heat pump water heater 55 degrees when the pressure is high and low?
- Different refrigerant pressure is not the same, commonly used refrigerant R22 compressor as an example:
- Q: Is the air heater easy to use in winter?
- Disadvantages of an air heater:Commercial problems of heat pump water heater1. Environmental adaptability problemAir source heat pump water heater with air as heat source, the energy efficiency ratio (COP) and normal working directly with the air source of the temperature, the current design of air source temperature on the market part of air source hot spring water heater to O ~ 40~C (Table 1, and a few other) l=L are rated at 25~C the design parameters of instrument, applies only to the Yangtze River in the south part of. The average temperature in the year is about 10C, and the temperature in winter is generally in the north of the Yangtze River in.10C. The air source heat pump water heater is difficult to achieve the desired energy saving effect. If the temperature to 20~C, the unit can not start, which greatly limits the air source heat pump water heater market space.
- Q: Operating principle of air energy water heater
- The use of heat pump working principle, heating, and air-conditioning refrigeration contrary - the national standard of refrigeration is 1000 watts, electric refrigeration 2800 watts. According to the principle of heat balance, heat generated at least 2800 watts of power, and the input electric power of 1000 watts, thermal power actually produced in 3000 - 4000 watts, the heat transfer to the heat preservation water tank, its power consumption is only 1/4 of the electric water heater (electric water heater is the thermal efficiency of 100%, input 1000 electrical only 1000 Joule heat).
Send your message to us
2.4kw Energy Saving a++ Split Type Radiator Heating and Cooling Heat Pump All in One Heating
- Loading Port:
- SHANGHAI
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 5000 pc/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches