Main Features
SF DZ-4 Ⅲ Power Quality Analyzer
1、Adopt IEC/61000-4-7, IEC61000-4-30 to measure harmonic and inter-harmonics. Minimum resolution of frequency is 5Hz.
Sampling period is 10 cycle. It can carry out 0.5 times (25HZ)inter-harmonics group and 0.1 times (5HZ)inter-harmonic
calculation.
2、High-speed fault analysis and recording strictly according to transient data exchange mode.
3、5- inch LED full color screen, graphical data display.
4、Provide full support to PQDIF data files.
SF DZ-4II Power Quality Analyzer
1、5-inch full color LCD display, human
operation interface.
2、Support keyboard and mouse operation. Support U disk data export.
3、Class Windows human-machine interface, which is humanistic and friendly.
4、Data analysis and report generation
5、More compact structure, more powerful function, more convenient display.
SF DZ-4I Power Quality Analyzer
Combine notebook computer with sampling system of high speed and accuracy to ensure accuracy of sampling signals.
1、Construct powerful power quality analysis system using plentiful software. The system consists of hardware sampling system and analysis software.
2、Adopt a serial port between sampling system and notebook.
Instrument function
1、Signal channel: measure 1×3 phase voltage signal and 1×3 current signal.
2、Measuring content: (power quality indexes made by national standard) 1-50 harmonic voltage, current distortion, valid value, phase angle, active power, inactive power, power factor, sequence component, voltage flicker, voltage fluctuate, signal waveform, spectrum, voltage deviation and frequency.
3、Measuring mode: There are 2 kinds of measuring modes. The first kind is sampling one cycle from signal each time and then do analysis. This method applies to measuring rapid changeable signal source. The second is to carry out 6 times equal interval sampling in 3 seconds. Analyze the measurement result of this 6 times sampling using FFS and then carry out RMS processing to distinguish transient phenomenon and harmonic.
Background Software Function
1、Power Quality Real-time Display: Real-time monitor、record at regular time、print out various power quality indexes.
2、Data Analysis: draw variation curve、harmonic distribution graph、statistical analysis、qualification rate calculation.
3、Power Quality Report Form: generate power quality report form at any time.
Measuring Connection
1、The front panel has voltage measurement socket “U”If measure phase voltage(Y-connection), please use plug marked “Y”If measure line voltage(△-connection), please use plug marked “△”
2、When measuring current signal, please plug clamp meter into the socket of the front
Panel, and then carry out measuring.
Technical Indexes
Voltage measuring range | AC voltage 10 - 400V | Current measuring range | AC current 0.05 - 6A | ||||
Frequency measuring range | 47.5~52.5Hz | ||||||
Harmonic analysis range | 00 – 50 times harmonic, “00”indicates voltage total distortion and total harmonic current valid value | ||||||
Harmonic voltage ratio | Uh≥1%UN σ≤±5%Uh Uh<1%UN σ≤±0.05%UN | ||||||
Harmonic current ratio | Ih≥±3%IN σ≤±5%Ih Ih<±3%IN σ≤±0.15%IN | ||||||
Accuracy of basic indexes | Voltage derivation error≤±0.5%;voltage fluctuation error≤±5%;flicker error≤±5;voltage dissymmetry factor absolute error< 0.2%;current dissymmetry factor absolute error< 1%;frequency measurement error< 0.01Hz | ||||||
Voltage side input DC resistance | > 100KΩ | Current side input DC resistance | < 0.1Ω | ||||
Working power supply | Voltage: AC220V±20% Frequency: 45-55Hz | ||||||
Voltage measuring range | AC voltage 10 - 400V | Current measuring range | AC current 0.05 - 6A | ||||
Frequency measuring range | 47.5~52.5Hz | ||||||
Harmonic analysis range | 00 – 50 times harmonic, “00”indicates voltage total distortion and total harmonic current valid value | ||||||
Harmonic voltage ratio | Uh≥1%UN σ≤±5%Uh Uh<1%UN σ≤±0.05%UN | ||||||
Harmonic current ratio | Ih≥±3%IN σ≤±5%Ih Ih<±3%IN σ≤±0.15%IN | ||||||
Accuracy of basic indexes | Voltage derivation error≤±0.5%;voltage fluctuation error≤±5%;flicker error≤±5;voltage dissymmetry factor absolute error< 0.2%;current dissymmetry factor absolute error< 1%;frequency measurement error< 0.01Hz | ||||||
Voltage side input DC resistance | > 100KΩ | Current side input DC resistance | < 0.1Ω | ||||
Working power supply | Voltage:AC220V±20% Frequency:45-55Hz |
Standard No. | Standard name | Note |
GB/T 15945—2008 | Power quality power system frequency deviation | |
GB/T 12325—2008 | Power quality supply voltage deviation | |
GB/T 15543—2008 | Power quality 3-phase voltage unbalance factor | |
GB/T 12326—2008 | Power quality voltage fluctuation and flicker | |
GB/T 14549—1993 | Power quality utility grid harmonic | |
GB/T 19862—2005 | Power quality monitoring equipment general requirement |
Send your message to us
Portable Power Quality Analyzer (SFDZ-4)5-inch full color LCD display
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 bottle
- Supply Capability:
- 100 bottle/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords