OTIS TOEC-40 Traction Roller
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 8000 Pieces per Quarter pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Packaging & Delivery OF OTIS TOEC-40 Traction Roller
Packaging Details: As you required!
Delivery Detail:Within three days after order confirmed.
Specifications OF OTIS TOEC-40 Traction Roller
a. color: different color
b.certification :CS&ISo9001.
c.MOQ:1-10pieces.
d.high quality&best prise
We can provide you all kinds of escalator lock.
YOUR CHOICE:
1.We are able to supply you a large variety of elevator components/ escalator parts of different brands
(a selection of more than2,000 kinds).
2.We can guarantee the product high quality, delivery time and good service.
3.We are able to manufacture according to your specific instructions and help you select appropriate product
and specification for you.
Looking forward to your inquiry!
- Q: Hitachi Elevator out of the 61 with the door of the lock after the opening of the arrow outside the instructions to flash how to repair
- May be caused by the connection of the motherboard. May be caused by damage to the internal parts of the machine. It is recommended to contact the maintenance staff can be repaired. An elevator is a motor-powered vertical lift with box-like pods for multi-storey construction or cargo. There are steps, stepping board mounted on the track for continuous operation, commonly known as escalators or automatic sidewalks. Serving the floor of the fixed lifting equipment. The vertical lift elevator has a car running between at least two rows of rigid or inclined rails with an inclination angle less than 15 °. Car size and structure to facilitate the passengers access to or loading and unloading of goods. It is customary to use the elevator as a general term for vertical traffic in a building, regardless of the way it is driven. According to the speed can be divided into low-speed elevators (1 m / s below), fast elevators (1 ~ 2 m / s) and high-speed elevators (2 m / s or more). The mid-19th century began to appear hydraulic elevator, is still in the low-rise buildings on the application. In 1852, the United States E.G. Otis developed a wire rope lift safety lift. 80 years, the drive device to further improve, such as the motor drive through the worm drive winding reel, the use of balance weight and so on. At the end of the 19th century, the use of friction wheel drive, greatly enhance the lift height of the elevator.
- Q: Elevator is divided into: passenger ladder, cargo ladder, passenger and freight ladder, sightseeing ladder, medical ladder. The Wait. Basic functions: Complete set of automatic control more
- Basic functions: overhaul operation, overload alarm, overspeed protection, double safety touch board protection, no call back to base station, walkie-talkie communication system, no call 3 minutes lighting and fan automatically stop, self-help operation, door closed door protection, Automatic adjustment, fault self-test storage display, power failure emergency lighting, electronic newspaper station clock, run the number of transmission, fire operation, the driver function
- Q: This is a question, who can give a full answer
- Commissioned to the qualification of the unit or the original manufacturing unit for daily maintenance. Maintenance and maintenance of the number of quality supervision; check whether the maintenance unit on time to maintain maintenance personnel maintenance elevator, whether according to the provisions of the time-by-day maintenance. Security personnel to provide a valid qualification certificate and do a good job in each maintenance note...
- Q: Please elaborate
- Maintenance of the elevator should be carried out. Records include at least the following: (a) the basic situation and technical parameters of the elevator, including the whole machine manufacturing, installation, transformation, the name of major maintenance units, elevator varieties (type), product number, equipment code, elevator prototype or after transformation (3) Maintenance units, maintenance date, maintenance personnel (signature); (4) the use of units, the use of the location, the use of the unit number; ) Maintenance of the elevator maintenance of the project (content), carried out maintenance work, to meet the requirements, the adjustment, replacement of wearing parts and other work when the detailed records. Maintenance records should be confirmed by the use of security signs signed by the unit. Maintenance of the basic technical parameters of the elevator include the following: (a) traction or forced drive passenger elevator, cargo elevator (hereinafter referred to as passenger elevator, cargo elevator), for the drive, rated load, rated Speed, number of floors; (2) hydraulic elevator, rated load, rated speed, number of floors, number of cylinders, jacking type; (c) debris elevator, for the drive, rated load, rated speed, Number of stations; (d) escalators and automatic sidewalks, for the tilt angle, rated speed, lift height, rung width, host power, the use of section length (automatic sidewalk). The quality inspection (inspection) personnel or management personnel of the maintenance unit shall carry out the inspection and maintenance of the maintenance quality of the elevator from time to time.
- Q: What are the electrical parts of the elevator and what are their roles?
- The control system (including the main board, car plate, instruction board, layer display board) is responsible for the elevator start, run and stop. Flat sensor: elevator leveling detection switch; door machine system (including door and door machine frequency converter): responsible for the elevator door. 2, safety touch panel and light curtain: car door entrance security protection; 3, limit switch: forced elevator stop of the terminal switch (in the bottom and the top of the set), the safety of the system, 4, the buffer: the roof of the elevator and the end of the end of a protection switch. Drag the system: traction machine, inverter, etc. to provide elevator running power;
- Q: In the airport shopping mall and other public places up and down the stairs or escalators should rely on what to stand?
- Some people say that the right, it was said to the left. A professional escalator engineer will tell you that the middle of the station. why? First, the user long-term left or right, will make the escalator long-term pressure, the side of the parts of the high frequency of damage, shorten the life of the escalator. Second, we rely on the side of the station, leaving the other side, is implied to let others walk from the gap. To know that the escalator is automatic, you use it to ask you to obediently stood. Please take the ordinary stairs to go. Or you go anxious, met someone else, we fell, and on both lose, haste not up to.
- Q: What are the general items of a construction project
- Hello, generally there are templates, steel, concrete, masonry, plaster, doors and windows, finishing and other sub-projects
- Q: Inside the restaurant such as the kitchen in the 1L and then the food to the top of the restaurant inside a machine called what name?
- Machine car
- Q: Grocery elevator is always automatically anti-leveling what is the reason
- Grocery elevator is always automatic anti-leveling reasons; ① due to poor lubrication or lubrication system failure will cause the parts of the transmission parts of the heat burns and axles, resulting in rolling or sliding parts of the parts damaged and forced to repair. ② did not carry out daily inspection and maintenance, failed to check the parts found in the transmission, rolling and sliding parts of the parts of the wear and wear conditions, not according to the degree of wear of the parts for the correct repair, resulting in damage to parts Forced to stop repair. ③ due to the elevator during the operation of the vibration caused by fastening bolts, so that parts displacement, loss of the original accuracy, and can not be repaired in time, resulting in grinding, touch, crashed mechanical parts were forced to stop repair. ④ because the elevator balance coefficient and the standard is too far from the difference caused by overloading the elevator car squatting or red roof, the top speed limiter and safety gear action and forced the elevator to stop running, waiting for repair.
- Q: For example, what records, is not to monitor what the third party? The More
- Anti-dropper to do third-party testing, and report
1. Manufacturer Overview
Location | Jiangsu,China (Mainland) |
Year Established | 2006 |
Annual Output Value | US$50 Million - US$100 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe; Central America; Northern Europe; Southern Europe; South Asia; Domestic Market |
Company Certifications | ISO Certificate |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Taicang PORT,Shanghhai PORT |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 6-10 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | 3 |
Contract Manufacturing | OEM Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
OTIS TOEC-40 Traction Roller
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 8000 Pieces per Quarter pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords