MPPT Wind Solar Hybrid Street Light Controller
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 8000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
I.PRODUCT INTRODUCTION
The wind/solar hybrid controller is specially designed for high-end small-scale wind/solar hybrid system and especially suitable for wind/solar hybrid street light system and wind/solar hybrid monitoring system.The controller can control wind turbine and solar panel at the same time and transform the wind and solar energy into electricity for DC load use, with excess energy stored into batteries. Varieties of appearance and function design, which is flexible to meet the requirements of different customers.
II.PERFORMANCE FEATURES
Superior military-grade components to ensure the product stability.
Superior military-grade components to ensure the product stability.
Check and set all operation parameters as requirement from LCD display.
Voltage limiting and current limiting charge mode ensures battery in the best charging status.
Two DC Load output, light control, time control, constant output, and multiple output control mode selections.
PWM stepless dumpload mode, which release the excess power into dump load, making the battery charging in best status.
Design of high quality aluminum alloy appearance, with small size and good cooling effect.
III.12V TECHNICAL PARAMETERS
Product Model | WWS02-12-L01D | WWS03-12-L01D | WWS04-12-L01D |
Rated battery voltage | 12V | 12V | 12V |
Rated wind turbine input voltage | 200W | 300W | 400W |
Maximum wind turbine input power | 300W | 450W | 600W |
Wind Turbine Brake Current | 20A | 30A | 40A |
Rated Solar Input Power | 150W | ||
Dumpload Start Voltage | 13.5V | ||
Complete discharge voltage | 14.5V | ||
Battery Under Voltage Shutoff | 10.8V | ||
Battery Under Voltage recovery | 12V | ||
Input over voltage shutoff | 16V | ||
Light Control On Voltage | 1V | ||
Light Control Off Voltage | 1.5V | ||
Rated Output Current of Load 1 and Load 2 | 10A | ||
Load 1 Output Control Mode | Light Control On and Light Control Off | ||
Load 2 Output Control Mode | Light Control On and Time Control 5 Hours Off | ||
Dumpload Control Mode | PWM | ||
Display Mode | LCD | ||
Cooling | Aluminium alloy shell radiating | ||
Protection Level | IP53(Indoor) | ||
Quiescent Current | ≤20 mA | ||
Display Content | Battery Voltage, Wind Turbine Voltage, PV Voltage, Wind Turbine Current, PV Current, Wind Turbine Power, PV Power, Over Voltage, Under Voltage, Over Load, Short Circuit, Night etc status | ||
Protection Functions | Solar reverse charge protection , Solar reverse connection protection, Battery over charge protection, Battery over discharge protection, Battery reverse connection protection, Over load protection, Short circuit protection, Lightning protection Wind turbine current limiting, Wind turbine automatic brake and manual brake. | ||
Ambient temperature | -20~+55℃ | ||
Ambient Humidity | 0~93%, without condensing | ||
Working Altitude | ≤4000m | ||
Wind Turbine Start Charge Voltage | 2V | ||
Input Admittance Value | 10/15 | ||
Dimension (L x W x H) | 223×152×82mm | ||
Net Weight | 2.8kg |
IV.24V TECHNICAL PARAMETERS
Product Model | WWS03-24-L01D | WWS04-24-L01D | WWS06-24-L01D |
Rated battery voltage | 24V | 24V | 24V |
Rated wind turbine input power | 300W | 400W | 600W |
Maximum wind turbine input power | 450W | 600W | 900W |
Rated solar input power | 300W | 300W | 300W |
Dumpload Start Voltage | 27V | 27V | 27V |
Charge Shutoff Voltage | 29V | 29V | 29V |
Wind Turbine Brake Current | 15A | 20A | 30A |
Battery Under Voltage Shutoff | 21.6V | ||
Battery Under Voltage Recovery | 24V | ||
Input Over Voltage Shutoff | 32V | ||
Light Control On Voltage | 2V | ||
Light Control Off Voltage | 3V | ||
Rated Output Current of Load 1 and Load 2 | 10A | ||
Load 1 Output Control Mode | Light Control On and Light Control Off | ||
Load 2 Output Control Mode | Light Control On and Time Control 5 Hours Off | ||
Dumpload Control Mode | PWM | ||
Display Mode | LCD | ||
Protection Level | IP53(Indoor) | ||
Quiescent Current | ≤20mA | ||
Display Content | Battery Voltage, Wind Turbine Voltage, PV Voltage, Wind Turbine Current, PV Current, Wind Turbine Power, PV Power, Over Voltage, Under Voltage, Over Load, Short Circuit, Night etc status | ||
Protection Functions | Solar reverse charge protection , Solar reverse connection protection, Battery over charge protection, Battery over discharge protection, Battery reverse connection protection, Over load protection, Short circuit protection, Lightning protection Wind turbine current limiting, Wind turbine automatic brake and manual brake. | ||
Ambient Temperature | -20~+55℃ | ||
Ambient Humidity | 0~93%, without condensing | ||
Working Altitude | ≤4000m | ||
Wind Turbine Start Charge Voltage | 4V | ||
Input Admittance Value | 10/30 | ||
Dimension (L x W x H) | 223×152×82mm | ||
Net Weight | 2.8kg |
V.48V TECHNICAL PARAMETERS
Product Model | WWS06-48-N00D |
Rated battery voltage | 48V |
Rated wind turbine input power | 600W |
Maximum wind turbine input power | 900W |
Rated solar input power | 300W |
Charge Shutoff Voltage | 58V |
Charge Recovery Voltage | 52.8V |
Wind Turbine Brake Current | 15A |
Battery Under Voltage Shutoff | 43.2V |
Battery Under Voltage Recovery | 48V |
Input Over Voltage Shutoff | 64V |
Light Control On Voltage | 4V |
Light Control Off Voltage | 6V |
Rated Output Current of Load 1 and Load 2 | 10A |
Load 1 Output Control Mode | Light Control On and Light Control Off |
Load 2 Output Control Mode | Light Control On and Time Control 5 Hours Off |
Display mode | LCD |
Protection Level | IP53(Indoor) |
Quiescent Current | ≤20mA |
Display Content | Battery Voltage, Wind Turbine Voltage, PV Voltage, Wind Turbine Current, PV Current, Wind Turbine Power, PV Power, Over Voltage, Under Voltage, Over Load, Short Circuit, Night etc status |
Protection Functions | Solar reverse charge protection , Solar reverse connection protection, Battery over charge protection, Battery over discharge protection, Battery reverse connection protection, Over load protection, Short circuit protection, Lightning protection Wind turbine current limiting, Wind turbine automatic brake and manual brake. |
Ambient temperature | -20~+55℃ |
Ambient Humidity | 0~93%, without condensing |
Working Altitude | ≤4000m |
Wind Turbine Start Charge Voltage | 8V |
Input Admittance Value | 5/60 |
Dimension (L x W x H) | 223×152×82mm |
Net Weight | 3kg |
VI. APPENDIX
Optional Function | ||
Ø RS232 communication function | Ø RS485 communication function | Ø Bluetooth function |
Ø Temperature compensation function | Ø By-pass function | Ø SD card function |
Ø GPRS communication function | Ø Wind speed detection function | Ø Wind turbine rotate speed detection function |
Ø Wind turbine low voltage charge function | Ø Wind turbine MPPT charging function | Ø Wind turbine low voltage charge function |
Optional Accessories | ||
Ø Ethernet Module | Ø GPRS | Ø SD card storage module |
Ø RS485-USB Converter | Ø RS485-RS232 Converter | Ø RS232-USB Converter |
Friendly reminder: Customers, who will order the wind/solar hybrid street light controller, need to provide the following information | ||
Ø Rated battery voltage | Ø Rated wind turbine power and rated solar power | Ø The wind turbine is three phase or single phase |
Qualifications | ||
Ø Utility model patent of anti-strong-wind, stepless unload wind power controller | ||
Ø Utility model patent of wind power boost charge circuit. | ||
Ø Utility model patent of SD card document storage | ||
Ø Utility model patent for integration of rectification and unload in wind power main circuit board. | ||
Ø Test Report of the ministry of information industry of posts and telecommunications industrial products quality supervision and inspection center | ||
Ø European CE certification. Ø Software product register certification |
In order to serve our customers better. Our company can adjust parameters configuration according to customer’s requirement.
- Q: Firewood (dry) is what type of energy
- Representative biomass such as crop, crop waste, wood, wood waste and animal waste. Narrow concept: biomass mainly refers to the agriculture and forestry production in addition to food, other than fruit stalks, trees and other wood cellulose (referred to as lignin), Agro industrial waste, agricultural waste and animal husbandry production process such as manure and waste materials. Features: renewable, low pollution, widely distributed.
- Q: Metro energy feedback products which good?
- By using 3MW super capacitor energy storage device for subway compensation cases, can save power 5.4 subway single braking start in Shenzhen, the price of 0.9 yuan calculation, single start braking can save electricity =5.4x0.9=4.86 yuan,
- Q: How to solve the energy problem
- The increase of investment in science and technology energy, and actively develop new products for energy saving, develop clean and renewable energy, and on China's high energy consumption, waste of resources of industrial enterprises to accelerate the technological transformation and upgrading, and actively optimize the industrial structure, promote energy conservation, improve energy utilization rate.
- Q: What are the types of new energy vehicles
- 2, hybrid electric vehicle:Refers to the use of conventional fuels, while with motor or engine to improve low-speed power output and fuel consumption models. In accordance with the different types of fuel, hybrid vehicles can be divided into two types of gasoline hybrid vehicles and diesel hybrid vehicles. At present, the mainstream of hybrid vehicles in China are mainly gasoline hybrid, while the international development of diesel hybrid models are relatively fast.
- Q: Trademark registration of energy and environmental protection is the first category
- Article 06: common metals and their alloys, metal building materials, transportable buildings of metal, metal rails, non electrical cables wires, five metal fittings, officer, safe, general metal products not included in other classes, oreClass 07: machines and machine tools, motors and engines (except for land vehicles), machine transmission couplings and transmission parts (except for land vehicles), non manual agricultural tools, incubatorsArticle 08: hand tools and implements (manual), cutlery, knives, razorArticle 09: Science, navigation, surveying, electrical, photography, film, optical, weighing, measuring, signal, inspection (supervision), ambulance (rescue) and teaching apparatus and instruments, apparatus recording, transmission or reproduction of sound and image, magnetic data carriers, recording discs, since the mechanical structure dynamic sales device and coin operated devices, cash register, computer and data processing device, fire extinguishing apparatus
- Q: What is the difference between energy star and DLC
- In the field of electronic energy consuming products, especially for the energy efficiency of lighting products, Anbotek as a EPA accredited laboratory in the United States, has more than and 10 years of experience, while obtaining the following authorization:EPA recognized Energy Star Testing LaboratoryCalifornia energy efficiency accreditation LaboratoryAccess to the U.S. Department of energy's LIGHTING FACTS LABEL authorized testing laboratory
- Q: What is the energy consumption per unit product
- (2) the individual energy consumption per unit product output refers to the amount of a certain amount of energy consumed in the production of a particular product. The index reflects the quantitative relationship between inputs and outputs. (3) the energy consumption per unit of comparable products refers to the total energy consumption per unit product of the same product in accordance with the standard process or standard product output under the same production conditions. Index Interpretation: this indicator reflects the level of production technology, product quality and management level of various industries and enterprises. It is the main index to evaluate the economic benefit and energy saving plan of the enterprise, and it is the important basis to formulate and modify the energy consumption quota and the product cost accounting. The characteristics of this index is, in the same industry between the various business units energy consumption comparable to eliminate similar between enterprises, because the product structure, production process, supply and demand structure caused by the different energy consumption are not comparable to the effect.
- Q: Just hired, listen to the boss, in the United States seems to be subject to tariff barriers, it seems that Europe has to impose punitive tariffs...... Would like to ask the industry, the market will be the future development of the market?
- Because of the decline in the cost of photovoltaic, trade stocks are devalued. Which buyers and sellers do not want to bypass the two dealers
- Q: At present, what are the main types of new energy vehicles?
- Pure electric vehicles (BEV, including solar cars):Is the main power to drive the car, at present, most of the models is directly driven by the motor, a part of the motor vehicle mounted in the engine compartment, there is also a part of the rotor four motors directly to the wheels as, and the difficulty of power storage technology.
- Q: What is the cost effectiveness ratio of energy management in energy quality?
- The laws of the state set the maximum value for the former, which set the minimum value; as a rigid index of energy efficiency regulationsAlthough different countries have different national conditions according to different national conditions, these two points are regarded as the final judging index
Send your message to us
MPPT Wind Solar Hybrid Street Light Controller
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 8000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords