I.PRODUCT INTRODUCTION
The wind/solar hybrid controller is specially designed for high-end small-scale wind/solar hybrid system and especially suitable for wind/solar hybrid street light system and wind/solar hybrid monitoring system.The controller can control wind turbine and solar panel at the same time and transform the wind and solar energy into electricity for DC load use, with excess energy stored into batteries. Varieties of appearance and function design, which is flexible to meet the requirements of different customers.
II.PERFORMANCE FEATURES
Superior military-grade components to ensure the product stability.
Superior military-grade components to ensure the product stability.
Check and set all operation parameters as requirement from LCD display.
Voltage limiting and current limiting charge mode ensures battery in the best charging status.
Two DC Load output, light control, time control, constant output, and multiple output control mode selections.
PWM stepless dumpload mode, which release the excess power into dump load, making the battery charging in best status.
Design of high quality aluminum alloy appearance, with small size and good cooling effect.
III.12V TECHNICAL PARAMETERS
Product Model | WWS02-12-L01D | WWS03-12-L01D | WWS04-12-L01D |
Rated battery voltage | 12V | 12V | 12V |
Rated wind turbine input voltage | 200W | 300W | 400W |
Maximum wind turbine input power | 300W | 450W | 600W |
Wind Turbine Brake Current | 20A | 30A | 40A |
Rated Solar Input Power | 150W | ||
Dumpload Start Voltage | 13.5V | ||
Complete discharge voltage | 14.5V | ||
Battery Under Voltage Shutoff | 10.8V | ||
Battery Under Voltage recovery | 12V | ||
Input over voltage shutoff | 16V | ||
Light Control On Voltage | 1V | ||
Light Control Off Voltage | 1.5V | ||
Rated Output Current of Load 1 and Load 2 | 10A | ||
Load 1 Output Control Mode | Light Control On and Light Control Off | ||
Load 2 Output Control Mode | Light Control On and Time Control 5 Hours Off | ||
Dumpload Control Mode | PWM | ||
Display Mode | LCD | ||
Cooling | Aluminium alloy shell radiating | ||
Protection Level | IP53(Indoor) | ||
Quiescent Current | ≤20 mA | ||
Display Content | Battery Voltage, Wind Turbine Voltage, PV Voltage, Wind Turbine Current, PV Current, Wind Turbine Power, PV Power, Over Voltage, Under Voltage, Over Load, Short Circuit, Night etc status | ||
Protection Functions | Solar reverse charge protection , Solar reverse connection protection, Battery over charge protection, Battery over discharge protection, Battery reverse connection protection, Over load protection, Short circuit protection, Lightning protection Wind turbine current limiting, Wind turbine automatic brake and manual brake. | ||
Ambient temperature | -20~+55℃ | ||
Ambient Humidity | 0~93%, without condensing | ||
Working Altitude | ≤4000m | ||
Wind Turbine Start Charge Voltage | 2V | ||
Input Admittance Value | 10/15 | ||
Dimension (L x W x H) | 223×152×82mm | ||
Net Weight | 2.8kg |
IV.24V TECHNICAL PARAMETERS
Product Model | WWS03-24-L01D | WWS04-24-L01D | WWS06-24-L01D |
Rated battery voltage | 24V | 24V | 24V |
Rated wind turbine input power | 300W | 400W | 600W |
Maximum wind turbine input power | 450W | 600W | 900W |
Rated solar input power | 300W | 300W | 300W |
Dumpload Start Voltage | 27V | 27V | 27V |
Charge Shutoff Voltage | 29V | 29V | 29V |
Wind Turbine Brake Current | 15A | 20A | 30A |
Battery Under Voltage Shutoff | 21.6V | ||
Battery Under Voltage Recovery | 24V | ||
Input Over Voltage Shutoff | 32V | ||
Light Control On Voltage | 2V | ||
Light Control Off Voltage | 3V | ||
Rated Output Current of Load 1 and Load 2 | 10A | ||
Load 1 Output Control Mode | Light Control On and Light Control Off | ||
Load 2 Output Control Mode | Light Control On and Time Control 5 Hours Off | ||
Dumpload Control Mode | PWM | ||
Display Mode | LCD | ||
Protection Level | IP53(Indoor) | ||
Quiescent Current | ≤20mA | ||
Display Content | Battery Voltage, Wind Turbine Voltage, PV Voltage, Wind Turbine Current, PV Current, Wind Turbine Power, PV Power, Over Voltage, Under Voltage, Over Load, Short Circuit, Night etc status | ||
Protection Functions | Solar reverse charge protection , Solar reverse connection protection, Battery over charge protection, Battery over discharge protection, Battery reverse connection protection, Over load protection, Short circuit protection, Lightning protection Wind turbine current limiting, Wind turbine automatic brake and manual brake. | ||
Ambient Temperature | -20~+55℃ | ||
Ambient Humidity | 0~93%, without condensing | ||
Working Altitude | ≤4000m | ||
Wind Turbine Start Charge Voltage | 4V | ||
Input Admittance Value | 10/30 | ||
Dimension (L x W x H) | 223×152×82mm | ||
Net Weight | 2.8kg |
V.48V TECHNICAL PARAMETERS
Product Model | WWS06-48-N00D |
Rated battery voltage | 48V |
Rated wind turbine input power | 600W |
Maximum wind turbine input power | 900W |
Rated solar input power | 300W |
Charge Shutoff Voltage | 58V |
Charge Recovery Voltage | 52.8V |
Wind Turbine Brake Current | 15A |
Battery Under Voltage Shutoff | 43.2V |
Battery Under Voltage Recovery | 48V |
Input Over Voltage Shutoff | 64V |
Light Control On Voltage | 4V |
Light Control Off Voltage | 6V |
Rated Output Current of Load 1 and Load 2 | 10A |
Load 1 Output Control Mode | Light Control On and Light Control Off |
Load 2 Output Control Mode | Light Control On and Time Control 5 Hours Off |
Display mode | LCD |
Protection Level | IP53(Indoor) |
Quiescent Current | ≤20mA |
Display Content | Battery Voltage, Wind Turbine Voltage, PV Voltage, Wind Turbine Current, PV Current, Wind Turbine Power, PV Power, Over Voltage, Under Voltage, Over Load, Short Circuit, Night etc status |
Protection Functions | Solar reverse charge protection , Solar reverse connection protection, Battery over charge protection, Battery over discharge protection, Battery reverse connection protection, Over load protection, Short circuit protection, Lightning protection Wind turbine current limiting, Wind turbine automatic brake and manual brake. |
Ambient temperature | -20~+55℃ |
Ambient Humidity | 0~93%, without condensing |
Working Altitude | ≤4000m |
Wind Turbine Start Charge Voltage | 8V |
Input Admittance Value | 5/60 |
Dimension (L x W x H) | 223×152×82mm |
Net Weight | 3kg |
VI. APPENDIX
Optional Function | ||
Ø RS232 communication function | Ø RS485 communication function | Ø Bluetooth function |
Ø Temperature compensation function | Ø By-pass function | Ø SD card function |
Ø GPRS communication function | Ø Wind speed detection function | Ø Wind turbine rotate speed detection function |
Ø Wind turbine low voltage charge function | Ø Wind turbine MPPT charging function | Ø Wind turbine low voltage charge function |
Optional Accessories | ||
Ø Ethernet Module | Ø GPRS | Ø SD card storage module |
Ø RS485-USB Converter | Ø RS485-RS232 Converter | Ø RS232-USB Converter |
Friendly reminder: Customers, who will order the wind/solar hybrid street light controller, need to provide the following information | ||
Ø Rated battery voltage | Ø Rated wind turbine power and rated solar power | Ø The wind turbine is three phase or single phase |
Qualifications | ||
Ø Utility model patent of anti-strong-wind, stepless unload wind power controller | ||
Ø Utility model patent of wind power boost charge circuit. | ||
Ø Utility model patent of SD card document storage | ||
Ø Utility model patent for integration of rectification and unload in wind power main circuit board. | ||
Ø Test Report of the ministry of information industry of posts and telecommunications industrial products quality supervision and inspection center | ||
Ø European CE certification. Ø Software product register certification |
In order to serve our customers better. Our company can adjust parameters configuration according to customer’s requirement.
- Q: What is a one-time energy
- Primary energy: refers to the natural form of the original form, the conversion of energy resources without processing. Natural energy.
- Q: State approved products called new energy foods
- The difference between new resource food and health food:1 health food refers to food with specific health functions, and approval must also be clear that what has a health care function, and the need for a health care function marked and defined on the product packaging, the new food resource has one or more functions are not on the product introduction mark in detail.2 new resources of food and health food for the application of the crowd is different, the former applies to any population, while the latter is suitable for specific populations.
- Q: What is the general energy?What do we usually say about energy conservation?
- Chapter I General ProvisionsArticle 1 this law is enacted for the purpose of promoting energy conservation, improving energy efficiency and economic efficiency, protecting the environment, ensuring the development of the national economy and society, and meeting the needs of the peopleSecond energy resources referred to in this Law refers to coal, crude oil, natural gas, electric power, coke, coal gas, heat, refined oil, liquefied petroleum gas, biomass energy and other directly or through processing, conversion and made useful to the various resources.
- Q: What is a high value-added products
- A lot of houses sold with only a few dollars. But from the spoon river sand refined silicon processing into CPU
- Q: What are the contents of bio energy
- Biomass includes plants, animals and their waste, garbage and organic waste water and other categories.
- Q: What are the tax policies for renewable energy companies?
- The national development and Reform Commission had issued the "renewable energy and long-term development plan" put forward, to 2020 the proportion of renewable energy in the energy structure to reach 16%, the proportion is still less than 1%. plan to increase financial input, the implementation of preferential tax policies "set down as a principle of the development and utilization of renewable energy.
- Q: I would like to ask you, China's electronic products have the use of energy classification, if so, what is the specific classification?
- Level 2 means comparison;Level 3 indicates that the energy efficiency of the product is the average level of the Chinese market;
- Q: What is the difference between energy star and DLC
- In the field of electronic energy consuming products, especially for the energy efficiency of lighting products, Anbotek as a EPA accredited laboratory in the United States, has more than and 10 years of experience, while obtaining the following authorization:EPA recognized Energy Star Testing LaboratoryCalifornia energy efficiency accreditation LaboratoryAccess to the U.S. Department of energy's LIGHTING FACTS LABEL authorized testing laboratory
- Q: What are the economic operating standards for energy equipment and systems?
- The core of building a resource conserving society is to correctly handle the relationship between man and nature, through the efficient use of resources, rational allocation and effective protection, economic and social and ecological sustainable development. The basic symbol of a resource conserving society is the harmony between man and nature. 1, the establishment of national policies and laws and regulations to conserve resources to strengthen the country in all areas of growth and comprehensive conservation management. In the organization of the preparation of the "11th Five-Year" national economic and social development master plan, special planning, regional planning and urban planning, we should save resources in the central position. The government should improve and perfect the resource conservation policies and regulations and supervision system, formulate corresponding policies and measures to encourage the economical use of resources, improve regulations and standards, the implementation of resource consumption and pollutant emission control strictly, and strengthen the binding force of saving resources work. To study and formulate "energy conservation law" and the "Cleaner Production Promotion Law) supporting regulations and regulations comprehensive utilization of resources, recycling of renewable resources, develop the industry of high consumption of resources to improve market access standards, the main energy efficiency standard, organization revised the main energy consuming industries for energy conservation design, develop key industry clean production evaluation index system.
- Q: What is the cost effectiveness ratio of energy management in energy quality?
- More and more countries pay attention to the energy efficiency of electrical products in the world, and now many countries regard the energy efficiency requirements as one of the mandatory targets for the sale of the products:EU: ErP (instead of EuP), European flower, CoC...United States: Energy Star (Energy Star), CEC, DoE...Canada: NRCan,Australia: MEPS,Korea: MEPS,China: CECP,
Send your message to us
MPPT Wind Solar Hybrid Street Light Controller
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 8000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords